{"title":"Air Handlers","description":"\u003cp\u003eDucted air handler family for split-system applications\u003c\/p\u003e\u003cp\u003eShop multi-position air handlers by capacity efficiency tier and installation orientation.\u003c\/p\u003e","products":[{"product_id":"air-dominion-10-kw-electric-heat-kit-multi-position-air-handlers","title":"Air Dominion 10 kW Electric Heat Kit for Multi-Position Air Handlers","description":"\u003cp\u003eAir Dominion 10 kW Electric Heat Kit for Multi-Position Air Handlers adds staged electric resistance heat to Air Dominion multi-position air handler systems - roughly 34,120 BTU\/h of backup or primary electric heat for cold snaps, defrost support, and all-electric installs. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e10 kW electric resistance heat element kit\u003c\/li\u003e\n\u003cli\u003eApproximately 34,120 BTU\/h heating output\u003c\/li\u003e\n\u003cli\u003eFits Air Dominion multi-position air handlers 18K-60K\u003c\/li\u003e\n\u003cli\u003eField-installed in the air handler electric-heat bay\u003c\/li\u003e\n\u003cli\u003eCoil-and-frame element construction with integral safety limits class\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapproximately 34,120 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFits air handler sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18K through 60K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-installed heat strip kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1-phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e10 kW electric heat strip kit\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMatch the kit to the air handler size using the fit table; breaker and conductor sizing follow the kit electrical tables and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eField installation by a qualified HVAC or electrical professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePrepared for Air Dominion quote review. Final kit electrical data, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhich air handlers does this kit fit?\u003c\/strong\u003e\u003cbr\u003eAir Dominion multi-position air handlers in the 18K through 60K range, per the factory fit table.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it installed at the factory?\u003c\/strong\u003e\u003cbr\u003eNo. Heat kits are field-installed in the air handler electric-heat bay during system installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo I still need the kit if I have a heat pump condenser?\u003c\/strong\u003e\u003cbr\u003eElectric heat is optional backup for heat-pump systems and primary heat for cooling-only systems; the right choice is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat breaker does it need?\u003c\/strong\u003e\u003cbr\u003eBreaker and wire sizing depend on kit kW and the air handler pairing; the electrical tables are confirmed in the quote packet.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-10KW-submittal_6128d078-0360-4181-bf2d-5fc30f8d01ba.pdf?v=1783049737\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-10KW-install-warranty_329b2930-a0d3-460b-a8a2-4be405718879.pdf?v=1783049737\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"Default Title","offer_id":48918047392000,"sku":"AD-HVAC-ACC-AH-HEAT-10KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_c0c2da52-0e0f-4409-a427-4be988b28670.png?v=1783047824"},{"product_id":"air-dominion-15-kw-electric-heat-kit-multi-position-air-handlers","title":"Air Dominion 15 kW Electric Heat Kit for Multi-Position Air Handlers","description":"\u003cp\u003eAir Dominion 15 kW Electric Heat Kit for Multi-Position Air Handlers adds staged electric resistance heat to Air Dominion multi-position air handler systems - roughly 51,180 BTU\/h of backup or primary electric heat for cold snaps, defrost support, and all-electric installs. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15 kW electric resistance heat element kit\u003c\/li\u003e\n\u003cli\u003eApproximately 51,180 BTU\/h heating output\u003c\/li\u003e\n\u003cli\u003eFits Air Dominion multi-position air handlers 36K-60K\u003c\/li\u003e\n\u003cli\u003eField-installed in the air handler electric-heat bay\u003c\/li\u003e\n\u003cli\u003eCoil-and-frame element construction with integral safety limits class\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapproximately 51,180 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFits air handler sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36K through 60K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-installed heat strip kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1-phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e15 kW electric heat strip kit\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMatch the kit to the air handler size using the fit table; breaker and conductor sizing follow the kit electrical tables and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eField installation by a qualified HVAC or electrical professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePrepared for Air Dominion quote review. Final kit electrical data, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhich air handlers does this kit fit?\u003c\/strong\u003e\u003cbr\u003eAir Dominion multi-position air handlers in the 36K through 60K range, per the factory fit table.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it installed at the factory?\u003c\/strong\u003e\u003cbr\u003eNo. Heat kits are field-installed in the air handler electric-heat bay during system installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo I still need the kit if I have a heat pump condenser?\u003c\/strong\u003e\u003cbr\u003eElectric heat is optional backup for heat-pump systems and primary heat for cooling-only systems; the right choice is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat breaker does it need?\u003c\/strong\u003e\u003cbr\u003eBreaker and wire sizing depend on kit kW and the air handler pairing; the electrical tables are confirmed in the quote packet.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-15KW-submittal_1c12b58e-039e-4eed-a1fa-1a2e9c1a03bd.pdf?v=1783049742\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-15KW-install-warranty_9ec1fb23-23ae-4c1a-9232-8d1e6e1f46e3.pdf?v=1783049742\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"Default Title","offer_id":48918050439424,"sku":"AD-HVAC-ACC-AH-HEAT-15KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_cf9ec78a-4b00-4929-9f17-91904fb14abd.png?v=1783047826"},{"product_id":"air-dominion-20-kw-electric-heat-kit-multi-position-air-handlers","title":"Air Dominion 20 kW Electric Heat Kit for Multi-Position Air Handlers","description":"\u003cp\u003eAir Dominion 20 kW Electric Heat Kit for Multi-Position Air Handlers adds staged electric resistance heat to Air Dominion multi-position air handler systems - roughly 68,240 BTU\/h of backup or primary electric heat for cold snaps, defrost support, and all-electric installs. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e20 kW electric resistance heat element kit\u003c\/li\u003e\n\u003cli\u003eApproximately 68,240 BTU\/h heating output\u003c\/li\u003e\n\u003cli\u003eFits Air Dominion multi-position air handlers 36K-60K\u003c\/li\u003e\n\u003cli\u003eField-installed in the air handler electric-heat bay\u003c\/li\u003e\n\u003cli\u003eCoil-and-frame element construction with integral safety limits class\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapproximately 68,240 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFits air handler sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36K through 60K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-installed heat strip kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1-phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e20 kW electric heat strip kit\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMatch the kit to the air handler size using the fit table; breaker and conductor sizing follow the kit electrical tables and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eField installation by a qualified HVAC or electrical professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePrepared for Air Dominion quote review. Final kit electrical data, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhich air handlers does this kit fit?\u003c\/strong\u003e\u003cbr\u003eAir Dominion multi-position air handlers in the 36K through 60K range, per the factory fit table.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it installed at the factory?\u003c\/strong\u003e\u003cbr\u003eNo. Heat kits are field-installed in the air handler electric-heat bay during system installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo I still need the kit if I have a heat pump condenser?\u003c\/strong\u003e\u003cbr\u003eElectric heat is optional backup for heat-pump systems and primary heat for cooling-only systems; the right choice is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat breaker does it need?\u003c\/strong\u003e\u003cbr\u003eBreaker and wire sizing depend on kit kW and the air handler pairing; the electrical tables are confirmed in the quote packet.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-20KW-submittal_29b03349-8aa5-48b3-9e21-012c498ff327.pdf?v=1783049823\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-20KW-install-warranty_2ef62552-76ad-4020-ba79-dbad3b25e8e8.pdf?v=1783049823\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"Default Title","offer_id":48918053519616,"sku":"AD-HVAC-ACC-AH-HEAT-20KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_6e04b889-e6ad-4c54-b064-207edf57f430.png?v=1783047828"},{"product_id":"air-dominion-5-kw-electric-heat-kit-multi-position-air-handlers","title":"Air Dominion 5 kW Electric Heat Kit for Multi-Position Air Handlers","description":"\u003cp\u003eAir Dominion 5 kW Electric Heat Kit for Multi-Position Air Handlers adds staged electric resistance heat to Air Dominion multi-position air handler systems - roughly 17,060 BTU\/h of backup or primary electric heat for cold snaps, defrost support, and all-electric installs. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e5 kW electric resistance heat element kit\u003c\/li\u003e\n\u003cli\u003eApproximately 17,060 BTU\/h heating output\u003c\/li\u003e\n\u003cli\u003eFits Air Dominion multi-position air handlers 18K-60K\u003c\/li\u003e\n\u003cli\u003eField-installed in the air handler electric-heat bay\u003c\/li\u003e\n\u003cli\u003eCoil-and-frame element construction with integral safety limits class\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapproximately 17,060 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFits air handler sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18K through 60K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-installed heat strip kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1-phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e5 kW electric heat strip kit\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMatch the kit to the air handler size using the fit table; breaker and conductor sizing follow the kit electrical tables and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eField installation by a qualified HVAC or electrical professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePrepared for Air Dominion quote review. Final kit electrical data, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhich air handlers does this kit fit?\u003c\/strong\u003e\u003cbr\u003eAir Dominion multi-position air handlers in the 18K through 60K range, per the factory fit table.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it installed at the factory?\u003c\/strong\u003e\u003cbr\u003eNo. Heat kits are field-installed in the air handler electric-heat bay during system installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo I still need the kit if I have a heat pump condenser?\u003c\/strong\u003e\u003cbr\u003eElectric heat is optional backup for heat-pump systems and primary heat for cooling-only systems; the right choice is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat breaker does it need?\u003c\/strong\u003e\u003cbr\u003eBreaker and wire sizing depend on kit kW and the air handler pairing; the electrical tables are confirmed in the quote packet.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-5KW-submittal_f1fb2cfc-4d34-4b05-9814-bdd53e00107d.pdf?v=1783049900\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-5KW-install-warranty_c0f883d8-7a27-4725-969f-b7d924595905.pdf?v=1783049901\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"Default Title","offer_id":48918053552384,"sku":"AD-HVAC-ACC-AH-HEAT-5KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_c2719d20-1236-4c1b-9202-3d1a59abe326.png?v=1783047830"},{"product_id":"air-dominion-7-5-kw-electric-heat-kit-multi-position-air-handlers","title":"Air Dominion 7.5 kW Electric Heat Kit for Multi-Position Air Handlers","description":"\u003cp\u003eAir Dominion 7.5 kW Electric Heat Kit for Multi-Position Air Handlers adds staged electric resistance heat to Air Dominion multi-position air handler systems - roughly 25,590 BTU\/h of backup or primary electric heat for cold snaps, defrost support, and all-electric installs. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e7.5 kW electric resistance heat element kit\u003c\/li\u003e\n\u003cli\u003eApproximately 25,590 BTU\/h heating output\u003c\/li\u003e\n\u003cli\u003eFits Air Dominion multi-position air handlers 18K-60K\u003c\/li\u003e\n\u003cli\u003eField-installed in the air handler electric-heat bay\u003c\/li\u003e\n\u003cli\u003eCoil-and-frame element construction with integral safety limits class\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapproximately 25,590 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFits air handler sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18K through 60K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-installed heat strip kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 1-phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e7.5 kW electric heat strip kit\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMatch the kit to the air handler size using the fit table; breaker and conductor sizing follow the kit electrical tables and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eField installation by a qualified HVAC or electrical professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\u003cli\u003ePrepared for Air Dominion quote review. Final kit electrical data, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhich air handlers does this kit fit?\u003c\/strong\u003e\u003cbr\u003eAir Dominion multi-position air handlers in the 18K through 60K range, per the factory fit table.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it installed at the factory?\u003c\/strong\u003e\u003cbr\u003eNo. Heat kits are field-installed in the air handler electric-heat bay during system installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo I still need the kit if I have a heat pump condenser?\u003c\/strong\u003e\u003cbr\u003eElectric heat is optional backup for heat-pump systems and primary heat for cooling-only systems; the right choice is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat breaker does it need?\u003c\/strong\u003e\u003cbr\u003eBreaker and wire sizing depend on kit kW and the air handler pairing; the electrical tables are confirmed in the quote packet.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-7.5KW-submittal_8f5c4477-ebf0-433b-ba49-5c30f452fb01.pdf?v=1783049906\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-AH-HEAT-7.5KW-install-warranty_341e6e44-8171-4da9-bbe9-7c70f9188234.pdf?v=1783049906\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"Default Title","offer_id":48918053880064,"sku":"AD-HVAC-ACC-AH-HEAT-7.5KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_1f3430cc-554f-49d8-b3bb-121fec7877db.png?v=1783047831"},{"product_id":"air-dominion-18000-btu-15-seer-multi-position-air-handler-system","title":"Air Dominion 18,000 BTU 15 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 18,000 BTU 15 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 15 SEER class single-stage scroll condenser with a multi-tap 5-speed ECM blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e18,000 BTU (1.5 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e15 SEER efficiency tier - 14.5 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18,000 BTU (1.5 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 SEER (14.5 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-tap 5-speed ECM direct-drive blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42-11\/16 H x 14-5\/16 W x 22-1\/16 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e525 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eStandard 24V thermostat control; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-18K-230-submittal_0832d1b6-5adf-4611-b4fd-ff60cd936d36.pdf?v=1783226597\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-18K-230-dimensional_2a7ae157-6725-4654-b88a-f9110a2d1045.pdf?v=1783226596\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-18K-230-install-warranty_9f1f1946-0cba-4aef-a309-71c8536db530.pdf?v=1783226596\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918055977216,"sku":"AD-HVAC-AH-15S-18K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918056009984,"sku":"AD-HVAC-AH-15S-18K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918056042752,"sku":"AD-HVAC-AH-15S-18K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918056075520,"sku":"AD-HVAC-AH-15S-18K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502204768512.png?v=1783226070"},{"product_id":"air-dominion-24000-btu-15-seer-multi-position-air-handler-system","title":"Air Dominion 24,000 BTU 15 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 24,000 BTU 15 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 15 SEER class single-stage scroll condenser with a multi-tap 5-speed ECM blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e24,000 BTU (2 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e15 SEER efficiency tier - 15.2 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU (2 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 SEER (15.2 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-tap 5-speed ECM direct-drive blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49-5\/8 H x 17-5\/8 W x 22-1\/16 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eStandard 24V thermostat control; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-24K-230-submittal_bfe32f65-f718-430d-bab9-a2490aa114fa.pdf?v=1783226602\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-24K-230-dimensional_f8e2e55d-80fa-4f16-9465-aaa9aae80d3e.pdf?v=1783226602\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-24K-230-install-warranty_a90f3bb7-1d0b-4778-9da7-be851a93895a.pdf?v=1783226602\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918067904768,"sku":"AD-HVAC-AH-15S-24K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918067937536,"sku":"AD-HVAC-AH-15S-24K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918067970304,"sku":"AD-HVAC-AH-15S-24K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918068003072,"sku":"AD-HVAC-AH-15S-24K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502204768512_d4c9048f-3119-4d76-93f4-fe217a7047ff.png?v=1783226075"},{"product_id":"air-dominion-30000-btu-15-seer-multi-position-air-handler-system","title":"Air Dominion 30,000 BTU 15 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 30,000 BTU 15 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 15 SEER class single-stage scroll condenser with a multi-tap 5-speed ECM blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e30,000 BTU (2.5 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e15 SEER efficiency tier - 15.2 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU (2.5 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 SEER (15.2 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-tap 5-speed ECM direct-drive blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eStandard 24V thermostat control; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-30K-230-submittal_890b71d8-c81c-4a81-987e-46da5c02b713.pdf?v=1783226607\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-30K-230-dimensional_4d799b2e-5593-4a88-85ff-8d3732d9af7b.pdf?v=1783226607\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-30K-230-install-warranty_b76e7b37-bd9f-473d-a727-598c780b8840.pdf?v=1783226607\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918068297984,"sku":"AD-HVAC-AH-15S-30K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918068330752,"sku":"AD-HVAC-AH-15S-30K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918068363520,"sku":"AD-HVAC-AH-15S-30K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918068396288,"sku":"AD-HVAC-AH-15S-30K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502204768512_4b91097a-78d2-4c78-afd2-5c4c81f9c2b5.png?v=1783226081"},{"product_id":"air-dominion-36000-btu-15-seer-multi-position-air-handler-system","title":"Air Dominion 36,000 BTU 15 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 36,000 BTU 15 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 15 SEER class single-stage scroll condenser with a multi-tap 5-speed ECM blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e36,000 BTU (3 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e15 SEER efficiency tier\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU (3 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 SEER (SEER2 confirmed during quote review)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-tap 5-speed ECM direct-drive blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eStandard 24V thermostat control; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-36K-230-submittal_a9c82bb2-085f-4b0e-8802-08e61c0e6e77.pdf?v=1783226612\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-36K-230-dimensional_47632498-3300-47d3-8b63-9dcbefad2c15.pdf?v=1783226612\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-36K-230-install-warranty_0cd4e479-5d36-4956-b781-f750575000b1.pdf?v=1783226613\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918071836928,"sku":"AD-HVAC-AH-15S-36K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918071869696,"sku":"AD-HVAC-AH-15S-36K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918071902464,"sku":"AD-HVAC-AH-15S-36K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918071935232,"sku":"AD-HVAC-AH-15S-36K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"15 kW","offer_id":48918071968000,"sku":"AD-HVAC-AH-15S-36K-230-15KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20 kW","offer_id":48918072000768,"sku":"AD-HVAC-AH-15S-36K-230-20KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502204768512_6cdd3e34-781a-455e-9681-d4c67f96ac24.png?v=1783226086"},{"product_id":"air-dominion-42000-btu-15-seer-multi-position-air-handler-system","title":"Air Dominion 42,000 BTU 15 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 42,000 BTU 15 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 15 SEER class single-stage scroll condenser with a multi-tap 5-speed ECM blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e42,000 BTU (3.5 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e15 SEER efficiency tier - 15.2 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42,000 BTU (3.5 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 SEER (15.2 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-tap 5-speed ECM direct-drive blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59-3\/16 H x 24-11\/16 W x 22-1\/16 D in. (upsized cabinet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1750 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eStandard 24V thermostat control; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-42K-230-submittal_b9512ab8-7da0-4085-bbce-46bbb42be602.pdf?v=1783226618\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-42K-230-dimensional_d68fa7df-4782-4226-b197-6c339a7a0cd8.pdf?v=1783226618\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-42K-230-install-warranty_3ded2720-9f2f-40ca-8611-d407fe79f4f4.pdf?v=1783226618\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918072164608,"sku":"AD-HVAC-AH-15S-42K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918072197376,"sku":"AD-HVAC-AH-15S-42K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918072230144,"sku":"AD-HVAC-AH-15S-42K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918072262912,"sku":"AD-HVAC-AH-15S-42K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"15 kW","offer_id":48918072295680,"sku":"AD-HVAC-AH-15S-42K-230-15KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20 kW","offer_id":48918072328448,"sku":"AD-HVAC-AH-15S-42K-230-20KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502204768512_d42cb866-b8f8-419c-bd55-ac4c3c182958.png?v=1783226092"},{"product_id":"air-dominion-48000-btu-15-seer-multi-position-air-handler-system","title":"Air Dominion 48,000 BTU 15 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 48,000 BTU 15 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 15 SEER class single-stage scroll condenser with a multi-tap 5-speed ECM blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e48,000 BTU (4 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e15 SEER efficiency tier - 15.0 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU (4 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 SEER (15.0 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-tap 5-speed ECM direct-drive blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53-7\/16 H x 21-1\/8 W x 22-1\/16 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e182 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1400 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eStandard 24V thermostat control; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-48K-230-submittal_9bd1a345-67f4-47d2-9ec6-6023c950f9ea.pdf?v=1783226623\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-48K-230-dimensional_0b35d1ce-e20f-4158-98f6-54ba6ea7c09f.pdf?v=1783226623\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-48K-230-install-warranty_fa873a23-45c6-45b6-8137-206d14b55603.pdf?v=1783226623\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918077767936,"sku":"AD-HVAC-AH-15S-48K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918077800704,"sku":"AD-HVAC-AH-15S-48K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918077833472,"sku":"AD-HVAC-AH-15S-48K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918077866240,"sku":"AD-HVAC-AH-15S-48K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"15 kW","offer_id":48918077899008,"sku":"AD-HVAC-AH-15S-48K-230-15KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20 kW","offer_id":48918077931776,"sku":"AD-HVAC-AH-15S-48K-230-20KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502204768512_3addbd57-2ed7-4a64-9a37-123d210fd512.png?v=1783226097"},{"product_id":"air-dominion-60000-btu-15-seer-multi-position-air-handler-system","title":"Air Dominion 60,000 BTU 15 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 60,000 BTU 15 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 15 SEER class single-stage scroll condenser with a multi-tap 5-speed ECM blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e60,000 BTU (5 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e15 SEER efficiency tier - 14.5 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU (5 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 SEER (14.5 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-tap 5-speed ECM direct-drive blower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59-3\/16 H x 24-11\/16 W x 22-1\/16 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum airflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1750 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eStandard 24V thermostat control; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-60K-230-submittal_e69055d8-fa7d-4f67-8582-cf5e71aea92b.pdf?v=1783226628\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-60K-230-dimensional_303a7058-0d83-452f-99b1-bed9f45973bb.pdf?v=1783226628\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-15S-60K-230-install-warranty_249944f2-cd51-4bbe-814d-0bde942dd19d.pdf?v=1783226628\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918078095616,"sku":"AD-HVAC-AH-15S-60K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918078128384,"sku":"AD-HVAC-AH-15S-60K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918078161152,"sku":"AD-HVAC-AH-15S-60K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918078193920,"sku":"AD-HVAC-AH-15S-60K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"15 kW","offer_id":48918078226688,"sku":"AD-HVAC-AH-15S-60K-230-15KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20 kW","offer_id":48918078259456,"sku":"AD-HVAC-AH-15S-60K-230-20KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502204768512_49afe464-866b-4db7-b40a-1a269ce3be5c.png?v=1783226103"},{"product_id":"air-dominion-24000-btu-18-seer-multi-position-air-handler-system","title":"Air Dominion 24,000 BTU 18 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 24,000 BTU 18 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 18 SEER class variable-speed inverter condenser with a variable-speed DC blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e24,000 BTU (2 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e18 SEER efficiency tier - 18.1 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24,000 BTU (2 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 SEER (18.1 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVariable-speed DC blower with 24V thermostat compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45.00 H x 21.02 W x 17.52 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondenser dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35.04 W x 13.46 D x 26.50 H in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eAny standard 24V thermostat with staged heat support; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-24K-230-submittal_18ee1de0-172a-4f42-89a6-57ed380f8f96.pdf?v=1783226634\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-24K-230-dimensional_128f3364-accf-44c4-b2b9-8c839a6c98b2.pdf?v=1783226634\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-24K-230-install-warranty_fc901e79-c273-4c36-9ed0-22e5e132c037.pdf?v=1783226634\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918082257152,"sku":"AD-HVAC-AH-18S-24K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918082289920,"sku":"AD-HVAC-AH-18S-24K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918082322688,"sku":"AD-HVAC-AH-18S-24K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918082355456,"sku":"AD-HVAC-AH-18S-24K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502210109696.png?v=1783226108"},{"product_id":"air-dominion-36000-btu-18-seer-multi-position-air-handler-system","title":"Air Dominion 36,000 BTU 18 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 36,000 BTU 18 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 18 SEER class variable-speed inverter condenser with a variable-speed DC blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e36,000 BTU (3 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e18 SEER efficiency tier - 16.1 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU (3 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 SEER (16.1 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVariable-speed DC blower with 24V thermostat compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49.02 H x 21.02 W x 21.02 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondenser dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.24 W x 16.14 D x 31.89 H in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eAny standard 24V thermostat with staged heat support; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-36K-230-submittal_26e8ad6d-be3f-4d65-8813-e17728bdc74a.pdf?v=1783226641\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-36K-230-dimensional_e866401f-a573-4e47-b6e0-d672d30a8266.pdf?v=1783226641\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-36K-230-install-warranty_d13bd91f-1efe-4747-9db9-1ccfa93aabb7.pdf?v=1783226641\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918085206272,"sku":"AD-HVAC-AH-18S-36K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918085239040,"sku":"AD-HVAC-AH-18S-36K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918085271808,"sku":"AD-HVAC-AH-18S-36K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918085304576,"sku":"AD-HVAC-AH-18S-36K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"15 kW","offer_id":48918085337344,"sku":"AD-HVAC-AH-18S-36K-230-15KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20 kW","offer_id":48918085370112,"sku":"AD-HVAC-AH-18S-36K-230-20KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502210502912.png?v=1783226114"},{"product_id":"air-dominion-48000-btu-18-seer-multi-position-air-handler-system","title":"Air Dominion 48,000 BTU 18 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 48,000 BTU 18 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 18 SEER class variable-speed inverter condenser with a variable-speed DC blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e48,000 BTU (4 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e18 SEER efficiency tier - 16.0 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU (4 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 SEER (16.0 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVariable-speed DC blower with 24V thermostat compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eAny standard 24V thermostat with staged heat support; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-48K-230-submittal_4de82890-36bc-4249-bb52-9f2c3ddb76e1.pdf?v=1783226647\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-48K-230-dimensional_3a0467c1-e0c4-41c0-881b-9f48f5dd0079.pdf?v=1783226647\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-48K-230-install-warranty_db8f3a8f-d29d-4f5b-97e2-22d84c601d59.pdf?v=1783226647\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918085533952,"sku":"AD-HVAC-AH-18S-48K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918085566720,"sku":"AD-HVAC-AH-18S-48K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918085599488,"sku":"AD-HVAC-AH-18S-48K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918085632256,"sku":"AD-HVAC-AH-18S-48K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"15 kW","offer_id":48918085665024,"sku":"AD-HVAC-AH-18S-48K-230-15KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20 kW","offer_id":48918085697792,"sku":"AD-HVAC-AH-18S-48K-230-20KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502210502912_13e5111f-9ad2-4965-88e2-5104cb8d429d.png?v=1783226120"},{"product_id":"air-dominion-60000-btu-18-seer-multi-position-air-handler-system","title":"Air Dominion 60,000 BTU 18 SEER Multi-Position Air Handler System","description":"\u003cp\u003eAir Dominion 60,000 BTU 18 SEER Multi-Position Air Handler System is a ducted central heating and cooling system pairing a 18 SEER class variable-speed inverter condenser with a variable-speed DC blower air handler. The air handler installs in vertical up, vertical down, or horizontal orientations, so it fits closets, attics, garages, and mechanical rooms without a special cabinet, and optional electric heat strips add staged backup heat. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e60,000 BTU (5 ton class) all-electric split system with matched condenser\u003c\/li\u003e\n\u003cli\u003e18 SEER efficiency tier - 15.2 SEER2 system rating at this size\u003c\/li\u003e\n\u003cli\u003e4-way multi-position cabinet: upflow, downflow, horizontal left or right\u003c\/li\u003e\n\u003cli\u003eOptional field-installed electric heat: 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW\u003c\/li\u003e\n\u003cli\u003eInsulated galvanized-steel cabinet controls heat loss and condensation\u003c\/li\u003e\n\u003cli\u003eA-shape coil with inner-groove copper tube and hydrophilic aluminum fins\u003c\/li\u003e\n\u003cli\u003eR454B current-production refrigerant platform\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU (5 ton class)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency tier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18 SEER (15.2 SEER2 system rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-position: upflow, downflow, horizontal left\/right\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion device\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVariable-speed DC blower with 24V thermostat compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW (field-installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208-230V, 60Hz, 1 phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabinet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e53 H x 24.5 W x 21 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMulti-position air handler cabinet\u003c\/li\u003e\n\u003cli\u003eMatched outdoor condenser\u003c\/li\u003e\n\u003cli\u003ePiston expansion device (factory-fitted)\u003c\/li\u003e\n\u003cli\u003eElectric heat strip kit only when selected as an option\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfirm orientation (upflow, downflow, horizontal), return\/supply duct transitions, and condensate routing before release.\u003c\/li\u003e\n\u003cli\u003eSelected electric heat kits are field-installed; breaker and wire sizing depend on the kit kW and are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eLine-set length, matched-condenser placement, and charge verification are confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes the system include the outdoor condenser?\u003c\/strong\u003e\u003cbr\u003eYes. This quoting record is a matched system: multi-position air handler plus outdoor condenser, with pairing finalized during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich electric heat sizes fit this unit?\u003c\/strong\u003e\u003cbr\u003eThis size accepts 5 kW, 7.5 kW, 10 kW, 15 kW, 20 kW kits. Factory electric-heat fit table: 5.0, 7.5, and 10.0 kW kits fit 18K-60K air handlers; 15.0 and 20.0 kW kits fit 36K-60K air handlers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be installed horizontally in an attic?\u003c\/strong\u003e\u003cbr\u003eYes. The cabinet is 4-way convertible for vertical up, vertical down, and horizontal left or right installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat thermostat does it use?\u003c\/strong\u003e\u003cbr\u003eAny standard 24V thermostat with staged heat support; controls scope is confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-60K-230-submittal_1ad2e4e0-d2ad-49f3-947c-46727e8fdcaa.pdf?v=1783226653\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-60K-230-dimensional_f6e261bd-cb10-482a-81ce-6685a4373904.pdf?v=1783226653\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-AH-18S-60K-230-install-warranty_f66f7837-a0ee-4176-a9d8-fd9209cb5c51.pdf?v=1783226653\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"None","offer_id":48918085828864,"sku":"AD-HVAC-AH-18S-60K-230-NOHEAT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5 kW","offer_id":48918085861632,"sku":"AD-HVAC-AH-18S-60K-230-5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918085894400,"sku":"AD-HVAC-AH-18S-60K-230-7P5KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 kW","offer_id":48918085927168,"sku":"AD-HVAC-AH-18S-60K-230-10KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"15 kW","offer_id":48918085959936,"sku":"AD-HVAC-AH-18S-60K-230-15KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20 kW","offer_id":48918085992704,"sku":"AD-HVAC-AH-18S-60K-230-20KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502210502912_37063b53-9b3c-4143-a03a-7350585e6a0b.png?v=1783226125"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/collections\/air-handlers.png?v=1783053919","url":"https:\/\/ironcinder.com\/collections\/air-handlers\/voltage_208v.oembed","provider":"IronCinder","version":"1.0","type":"link"}