{"title":"Breakers and Load Centers","description":"\u003cp\u003eSingle pole and 2 pole breakers with GFCI and AFCI protection options, plus main and sub panel load centers. Panel and breaker compatibility is confirmed at quote review so every slot fills correctly. Send your panel schedule for a project quote.\u003c\/p\u003e","products":[{"product_id":"light-archon-aegis-20a-single-pole-circuit-breaker","title":"Light Archon Aegis 20A Single-Pole Circuit Breaker","description":"\u003cp\u003eLight Archon Aegis breakers put the everyday 20 A single-pole slot on one platform in the industry-standard 1 in. plug-on format. Protection levels run from the standard thermal magnetic unit to a tandem two-circuit unit, an AFCI unit, and a dual function AF\/GF unit, so one line item covers the full branch circuit schedule. Every unit is quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eThe standard unit trips to the center position on overload or fault current, so a tripped handle reads at a glance. The tandem unit fits two 20 A circuits in one pole space where the panel label permits it. AFCI and dual function units add arc fault and combined arc plus ground fault protection for the dwelling circuits the NEC calls out. Interrupt rating is 10 kA across the line, and terminations accept #14-4 AWG Cu\/Al conductors at 60 C or 75 C.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e20 A single-pole platform in the 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003eStandard, tandem two-circuit, AFCI, and dual function AF\/GF levels\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip unit; trips to center for clear fault indication\u003c\/li\u003e\n\u003cli\u003ePlug-on bus connection with no mounting hardware\u003c\/li\u003e\n\u003cli\u003eTerminations accept #14-4 AWG Cu\/Al conductors\u003c\/li\u003e\n\u003cli\u003eUL Listed and ANSI certified platform\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, 1 in. format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V standard and tandem units; AFCI and dual function units rated 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, tandem two-circuit, AFCI, dual function AF\/GF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e#14-4 AWG Cu\/Al at 60 C or 75 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, ANSI certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne breaker per unit, protection level per selected variant\u003c\/li\u003e\n\u003cli\u003eAFCI and dual function units include their factory pigtail or plug-on neutral hardware\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eAFCI and GFCI protection locations follow the NEC edition adopted in your jurisdiction\u003c\/li\u003e\n\u003cli\u003eTandem units go only in slots the panel label permits\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich protection level do I need?\u003c\/strong\u003e\u003cbr\u003eStandard units cover most branch circuits. The NEC calls for AFCI protection in most dwelling living areas and combined AF\/GF units where the plan calls for both arc and ground fault protection on one circuit. Your electrician and the trade desk confirm the schedule at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I use the tandem unit anywhere in the panel?\u003c\/strong\u003e\u003cbr\u003eNo. Tandem units belong only in slots the panel label lists as tandem-permitted. The panel schedule is checked at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-AEGIS-submittal.pdf?v=1783306765\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-AEGIS-dimensional.pdf?v=1783306765\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-AEGIS-install-warranty.pdf?v=1783306765\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Standard","offer_id":48934490571008,"sku":"LA-LGT-BRK-A20-AEGIS-STD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Tandem Two Circuit","offer_id":48934490603776,"sku":"LA-LGT-BRK-A20-AEGIS-TDM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"AFCI","offer_id":48934490636544,"sku":"LA-LGT-BRK-A20-AEGIS-AFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Dual Function AF GF","offer_id":48934490669312,"sku":"LA-LGT-BRK-A20-AEGIS-DFC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_1d8eedc1-1110-4ea7-bcf6-408c130f8a30.png?v=1783306374"},{"product_id":"light-archon-talos-20a-single-pole-circuit-breaker","title":"Light Archon Talos 20A Single-Pole Circuit Breaker","description":"\u003cp\u003eLight Archon Talos breakers carry the 20 A single-pole branch slot in a 1 in. plug-on format with four protection levels: standard thermal magnetic, ground fault with built-in self-test, arc fault, and a dual function unit that combines both. The platform is quote-first, and the trade desk verifies panel fit on every line before release.\u003c\/p\u003e\u003cp\u003eTin-plated copper stabs make a corrosion-resistant bus connection, and the heat-resistant thermoset case holds calibration over the service life; the calibration screw is cemented to prevent shift. Handles trip to the center position so a fault reads at a glance. The ground fault unit runs an automatic self-test and trips if it loses the ability to protect the circuit, per the self-test requirement in current UL practice.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e20 A single-pole platform, 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003eStandard, GFCI self-test, AFCI, and dual function AF\/GF levels\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eTin-plated copper stabs for a corrosion-resistant connection\u003c\/li\u003e\n\u003cli\u003eHeat-resistant thermoset case with cemented calibration screw\u003c\/li\u003e\n\u003cli\u003eTrips to center position for clear fault indication\u003c\/li\u003e\n\u003cli\u003eUL Listed, ANSI certified, CSA listed\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, 1 in. format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, GFCI self-test, AFCI, dual function AF\/GF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStabs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTin-plated copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat-resistant thermoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, ANSI certified, CSA listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne breaker per unit, protection level per selected variant\u003c\/li\u003e\n\u003cli\u003eSelf-test electronics built into the GFCI and dual function units\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eBox type terminals; torque to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eGFCI and AFCI protection locations follow the NEC edition adopted in your jurisdiction\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the ground fault unit self-test?\u003c\/strong\u003e\u003cbr\u003eYes. The GFCI unit runs a built-in self-test and trips if it loses the ability to protect, so a failed device does not sit silent in the panel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich protection level do I need?\u003c\/strong\u003e\u003cbr\u003eStandard covers most branch circuits; the NEC calls for AFCI in most dwelling living areas and GFCI in wet and damp locations. The dual function unit satisfies both on one circuit. Your electrician confirms the schedule at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. The site shows a zero price; the trade desk prices your quote list and checks panel fit line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-TALOS-submittal_a046bff2-e579-4003-bd32-9e5aa6e08414.pdf?v=1783446587\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-TALOS-dimensional_780f549e-0a00-407c-950d-a66df7a8f371.pdf?v=1783446586\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-TALOS-install-warranty_6d9175c7-a9e5-464a-821c-51cc5bb81210.pdf?v=1783446587\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Standard","offer_id":48934490702080,"sku":"LA-LGT-BRK-A20-TALOS-STD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"GFCI Self Test","offer_id":48934490734848,"sku":"LA-LGT-BRK-A20-TALOS-GFT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"AFCI","offer_id":48934490767616,"sku":"LA-LGT-BRK-A20-TALOS-AFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Dual Function AF GF","offer_id":48934490800384,"sku":"LA-LGT-BRK-A20-TALOS-DFC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38521123307776.png?v=1783428303"},{"product_id":"light-archon-rampart-200a-plug-on-neutral-load-center","title":"Light Archon Rampart 200A Plug-On Neutral Load Center","description":"\u003cp\u003eLight Archon Rampart load centers anchor the service at 200 A with a plug-on neutral bus that cuts branch breaker install time. The platform spans 8-space to 30-space configurations, indoor and outdoor, with factory-installed main breakers on the main breaker units and a main lug option for subfeed work. Quote-first: the trade desk confirms the configuration and breaker schedule before release.\u003c\/p\u003e\u003cp\u003eThe rust-resistant galvanized steel tub carries a split neutral rated 100 percent on each side with full-length neutral bars, so wire lands fast on either flank. Top and bottom feed both work. Outdoor units carry a NEMA 3R enclosure; indoor units are NEMA 1. Value pack configurations ship with an assortment of single-pole and double-pole branch breakers, and the 8-space outdoor unit adds feed-through lugs for downstream panels. Series interrupt rating is 22 kA, confirmed per configuration at quote review.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e200 A plug-on neutral platform, 8 to 30 spaces\u003c\/li\u003e\n\u003cli\u003eFactory-installed main breaker on main breaker configurations\u003c\/li\u003e\n\u003cli\u003eSplit neutral rated 100 percent on each side, full-length neutral bars\u003c\/li\u003e\n\u003cli\u003eRust-resistant galvanized steel enclosure\u003c\/li\u003e\n\u003cli\u003eNEMA 3R outdoor and NEMA 1 indoor configurations\u003c\/li\u003e\n\u003cli\u003eTop or bottom feed with all neutral holes rated for 14-4 wire\u003c\/li\u003e\n\u003cli\u003eFeed-through lug option for downstream panels\u003c\/li\u003e\n\u003cli\u003e22 kA series interrupt rating\u003c\/li\u003e\n\u003cli\u003eUL Listed, meets ANSI safety requirements\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V, single phase, 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 to 30 spaces, 16 to 60 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on neutral; split neutral rated 100 percent per side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 kA series rating, per configuration at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanized steel, rust resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R outdoor and NEMA 1 indoor configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTop or bottom feed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts Light Archon Talos series 1 in. plug-on branch breakers - schedule verified at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain breaker factory installed on main breaker configurations; branch assortment on value packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, meets ANSI safety requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure with cover, NEMA rated per configuration\u003c\/li\u003e\n\u003cli\u003eFactory-installed main breaker on main breaker configurations\u003c\/li\u003e\n\u003cli\u003eBranch breaker assortment on value pack configurations, confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eClosure caps; hubs quoted separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician as service equipment or subpanel per plan\u003c\/li\u003e\n\u003cli\u003eSurface mount; keep working clearance per NEC at the enclosure face\u003c\/li\u003e\n\u003cli\u003eBond and ground per NEC; separate grounded and bond conductors in subpanel use\u003c\/li\u003e\n\u003cli\u003eHub and conduit entries sized and sealed by the installer for outdoor work\u003c\/li\u003e\n\u003cli\u003eBranch breaker schedule finalized at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat breakers does it accept?\u003c\/strong\u003e\u003cbr\u003eLight Archon Talos series 1 in. plug-on branch breakers. The exact breaker schedule for your job is confirmed at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it mount outdoors?\u003c\/strong\u003e\u003cbr\u003eYes. Outdoor configurations carry a NEMA 3R rust-resistant enclosure; indoor configurations are NEMA 1. Pick the variant that matches the location.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the main breaker included?\u003c\/strong\u003e\u003cbr\u003eMain breaker configurations ship with the main device factory installed. The 20-space indoor main lug unit has no main device and is fed from an upstream breaker.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat comes in a value pack?\u003c\/strong\u003e\u003cbr\u003eThe enclosure, cover, factory-installed main breaker, and an assortment of single-pole and double-pole branch breakers. The assortment is itemized at quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S20-RMPRT-submittal.pdf?v=1783306876\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S20-RMPRT-dimensional.pdf?v=1783306876\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S20-RMPRT-install-warranty.pdf?v=1783306877\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"20-Space 40-Circuit Main Breaker Outdoor","offer_id":48934493913344,"sku":"LA-LGT-LC-S20-RMPRT-20MBO","price":0.0,"currency_code":"USD","in_stock":true},{"title":"30-Space 60-Circuit Main Breaker Outdoor","offer_id":48934493946112,"sku":"LA-LGT-LC-S20-RMPRT-30MBO","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8-Space 16-Circuit Main Breaker Outdoor Feed-Through","offer_id":48934493978880,"sku":"LA-LGT-LC-S20-RMPRT-08MBF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"30-Space 60-Circuit Main Breaker Indoor","offer_id":48934494011648,"sku":"LA-LGT-LC-S20-RMPRT-30MBI","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20-Space 40-Circuit Main Lug Indoor","offer_id":48934494044416,"sku":"LA-LGT-LC-S20-RMPRT-20MLI","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_68b8ba4c-59d1-4a2c-823c-ec1af8926cb0.png?v=1783306453"},{"product_id":"light-archon-bulwark-125a-main-lug-load-center","title":"Light Archon Bulwark 125A Main Lug Load Center","description":"\u003cp\u003eLight Archon Bulwark main lug load centers handle subpanel and small-feed distribution at 125 A, from a compact 4-space outdoor box to a 20-space indoor panel with factory ground bar. All units are quote-first; the trade desk confirms the configuration and the feeder plan before release.\u003c\/p\u003e\u003cp\u003eThe aluminum bus is rated 125 A with a 10 kA interrupt rating on the verified indoor unit. Indoor units are NEMA 1; outdoor units carry a NEMA 3R cover. The 8-space indoor unit has a flush door with a drywall depth mark on the enclosure and a single keyhole mount at the top for fast leveling, plus a center knockout for conduit entry. A rigid one-piece plastic backpan seats the branch breakers solidly, and the 12-space contractor kit ships with two 20 A single-pole breakers to start the schedule.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e125 A main lug platform, 4 to 20 spaces\u003c\/li\u003e\n\u003cli\u003eAluminum bus; plug-on neutral on the 20-space and 12-space units\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating on the verified indoor unit\u003c\/li\u003e\n\u003cli\u003eNEMA 1 indoor and NEMA 3R outdoor configurations\u003c\/li\u003e\n\u003cli\u003eFlush door option with drywall depth mark for clean finish work\u003c\/li\u003e\n\u003cli\u003eSingle keyhole top mount for fast leveling\u003c\/li\u003e\n\u003cli\u003eCenter knockout for conduit entry\u003c\/li\u003e\n\u003cli\u003eContractor kit configuration includes two 20 A single-pole breakers\u003c\/li\u003e\n\u003cli\u003eUL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain lug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 spaces, 8 to 40 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAluminum; plug-on neutral on select configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA on the verified indoor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 1 indoor and NEMA 3R outdoor configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlush or surface per configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKnockouts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCenter knockout for conduit entry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e#14-1\/0 AWG Cu\/Al at 60 C or 75 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts Light Archon Aegis series 1 in. plug-on breakers - schedule verified at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure with cover or flush door per configuration\u003c\/li\u003e\n\u003cli\u003eFactory ground bar on the 20-space configuration\u003c\/li\u003e\n\u003cli\u003eTwo 20 A single-pole breakers with the 12-space contractor kit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; typically fed from an upstream breaker as a subpanel\u003c\/li\u003e\n\u003cli\u003eFlush units use the drywall depth mark on the enclosure for finish depth\u003c\/li\u003e\n\u003cli\u003eBond and ground per NEC; separate grounded and bond conductors in subpanel use\u003c\/li\u003e\n\u003cli\u003eFeeder conductors sized by the installer to the connected load\u003c\/li\u003e\n\u003cli\u003eBranch breaker schedule finalized at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat breakers does it accept?\u003c\/strong\u003e\u003cbr\u003eLight Archon Aegis series 1 in. plug-on breakers. The schedule for your job is confirmed at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this a main panel or a subpanel?\u003c\/strong\u003e\u003cbr\u003eIt is a main lug platform, so there is no main device in the box. It is typically fed from an upstream breaker and used as a subpanel; your electrician sizes the feeder.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFlush or surface mount?\u003c\/strong\u003e\u003cbr\u003ePer configuration. The 8-space indoor flush door unit is made for in-wall finish work and carries a drywall depth mark; outdoor units surface mount with a NEMA 3R cover.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it come with breakers?\u003c\/strong\u003e\u003cbr\u003eThe 12-space contractor kit includes two 20 A single-pole breakers. Other configurations ship as enclosure and cover only, with breakers quoted separately.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S8-BLWRK-submittal.pdf?v=1783306883\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S8-BLWRK-dimensional.pdf?v=1783306882\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S8-BLWRK-install-warranty.pdf?v=1783306883\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"8-Space 16-Circuit Indoor Flush Door","offer_id":48934494109952,"sku":"LA-LGT-LC-S8-BLWRK-08IF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20-Space 40-Circuit Indoor Ground Bar","offer_id":48934494142720,"sku":"LA-LGT-LC-S8-BLWRK-20IG","price":0.0,"currency_code":"USD","in_stock":true},{"title":"4-Space 8-Circuit Outdoor","offer_id":48934494175488,"sku":"LA-LGT-LC-S8-BLWRK-04OR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8-Space 16-Circuit Outdoor","offer_id":48934494208256,"sku":"LA-LGT-LC-S8-BLWRK-08OR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12-Space 24-Circuit Indoor Contractor Kit","offer_id":48934494241024,"sku":"LA-LGT-LC-S8-BLWRK-12IK","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_924256d2-e619-4cd3-a06e-f02ecca1b7ac.png?v=1783306462"},{"product_id":"light-archon-vanguard-100a-2-pole-circuit-breaker","title":"Light Archon Vanguard 100A 2-Pole Circuit Breaker","description":"\u003cp\u003eThe Light Archon Vanguard 100A 2-pole breaker anchors heavy feeder and main-class duty in the industry-standard 1 in. plug-on format. It backfeeds or protects 100 A of 120\/240V service in two pole spaces, serving subpanel feeders and main positions in load centers listed for it. Quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eThe thermal magnetic trip unit carries a common trip across both poles and a 10 kA interrupt rating. The plug-on connection lands the breaker on the bus without mounting hardware, and the two-space footprint keeps subpanel feeder layouts compact. Typical work: feeding a detached garage or shop subpanel, protecting a 100 A service section, or replacing a feeder position during a panel refresh, always with the load center listing and conductor sizing checked by your electrician.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e100 A 2-pole unit in the 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003e120\/240V rating for feeder and main-class positions\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip with common trip across both poles\u003c\/li\u003e\n\u003cli\u003ePlug-on bus connection with no mounting hardware\u003c\/li\u003e\n\u003cli\u003eTwo pole spaces in compatible load centers\u003c\/li\u003e\n\u003cli\u003eUL Listed and ANSI certified\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole, 1 in. format, two pole spaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic, common trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eService\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeeder or main position where the load center is listed for it\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, ANSI certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eOne 100 A 2-pole breaker per unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eMain or backfeed positions require the load center listing and any required hold-down kit\u003c\/li\u003e\n\u003cli\u003eTakes two adjacent pole spaces on the panel bus\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it serve as a main breaker?\u003c\/strong\u003e\u003cbr\u003eYes, where the load center is listed for a 100 A plug-on main or backfeed position and the required hold-down hardware is used. Your electrician and the trade desk confirm the listing at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat conductor does a 100 A feeder need?\u003c\/strong\u003e\u003cbr\u003eConductor sizing follows the NEC for the load and termination temperature rating; your electrician sizes it from the panel schedule. The trade desk can include the feeder run on the same quote.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A100-VNGRD-submittal_b057b34b-28f9-458c-b9f1-774d70f0bbc9.pdf?v=1783446605\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A100-VNGRD-dimensional_933110e1-13cc-4256-96dc-f6d667cfaa35.pdf?v=1783446605\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A100-VNGRD-install-warranty_ca7b3c03-67e9-4306-9bac-6d016b20ebbf.pdf?v=1783446606\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Default Title","offer_id":48943861203200,"sku":"LA-LGT-BRK-A100-VNGRD","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38533710381312.png?v=1783443816"},{"product_id":"light-archon-palisade-15a-single-pole-circuit-breaker","title":"Light Archon Palisade 15A Single-Pole Circuit Breaker","description":"\u003cp\u003eLight Archon Palisade breakers cover the 15 A single-pole slot in the industry-standard 1 in. plug-on format. Two protection levels share the platform: a standard thermal magnetic unit for general branch circuits and a dual function AF\/GF unit that puts arc fault and ground fault protection in one device with a single point of reset. Every unit is quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eThe standard unit is a straightforward thermal magnetic breaker rated 120\/240V. The dual function unit protects the entire circuit, including home runs, against both arc faults and ground faults, and its integral LED reads out trip codes that separate thermal overload from fault trips, cutting troubleshooting time. A short-body case and reduced pigtail clutter keep gutter space open for conductor work. Interrupt rating is 10 kA across the line, and both units land on the bus with a plug-on connection.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15 A single-pole platform in the 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003eStandard and dual function AF GF protection levels\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eDual function unit combines AFCI and GFCI protection with one reset point\u003c\/li\u003e\n\u003cli\u003eLED diagnostic trip codes on the dual function unit speed troubleshooting\u003c\/li\u003e\n\u003cli\u003eShort-body case maximizes gutter space for conductor installation\u003c\/li\u003e\n\u003cli\u003ePlug-on bus connection with no mounting hardware\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, 1 in. format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V standard unit; dual function AF\/GF unit rated 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic standard unit; electronic with LED trip codes on dual function unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, dual function AF\/GF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual function unit ships with a factory neutral pigtail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne breaker per unit, protection level per selected variant\u003c\/li\u003e\n\u003cli\u003eDual function unit includes its factory neutral pigtail\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eDual function AF\/GF protection locations follow the NEC edition adopted in your jurisdiction\u003c\/li\u003e\n\u003cli\u003eLand the dual function unit pigtail on the panel neutral bar\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does the dual function unit protect against?\u003c\/strong\u003e\u003cbr\u003eBoth arc faults and ground faults on the same circuit, including the home run, with a single device and one reset point. The integral LED flashes trip codes so your electrician can tell a thermal overload from a fault trip.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhen is dual function protection required?\u003c\/strong\u003e\u003cbr\u003eThe NEC calls for AFCI protection in most dwelling living areas and GFCI protection in wet and damp locations; a dual function unit covers circuits where the plan calls for both. Your electrician and the trade desk confirm the schedule at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A15-PLSD-submittal.pdf?v=1783373117\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A15-PLSD-dimensional.pdf?v=1783373117\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A15-PLSD-install-warranty.pdf?v=1783373117\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Standard","offer_id":48943861268736,"sku":"LA-LGT-BRK-A15-PLSD-STD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Dual Function AF GF","offer_id":48943861301504,"sku":"LA-LGT-BRK-A15-PLSD-DFC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_4f6f346f-fdbb-4bdf-a875-ef6c3d0c1856.png?v=1783372879"},{"product_id":"light-archon-citadel-20a-circuit-breaker-platform","title":"Light Archon Citadel 20A Circuit Breaker Platform","description":"\u003cp\u003eLight Archon Citadel breakers put the full 20 A branch schedule on one platform in the industry-standard 1 in. plug-on format. Configurations run single-pole, tandem two-circuit, and 2-pole; protection levels run from standard thermal magnetic units through AFCI, GFCI, and dual function AF\/GF electronics, with the AFCI and dual function levels offered in pigtail or plug-on neutral connection to match the panel. Every unit is quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eStandard, tandem, and 2-pole units use a thermal magnetic trip rated 120\/240V; the tandem fits two 20 A circuits in one pole space where the panel label permits, and the 2-pole unit serves 240V loads across two spaces. AFCI units add combination arc fault protection for dwelling living areas, GFCI units add Class A ground fault protection, and dual function units combine both behind a single reset. Plug-on neutral versions land the neutral through the mounting foot on panels with a plug-on neutral bus, eliminating the pigtail and keeping gutter space clear. Interrupt rating is 10 kA across the line.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e20 A platform in the 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003eSingle-pole, tandem two-circuit, and 2-pole configurations\u003c\/li\u003e\n\u003cli\u003eStandard, AFCI, GFCI, and dual function AF GF protection levels\u003c\/li\u003e\n\u003cli\u003ePigtail or plug-on neutral connection on AFCI and dual function levels\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip on standard units; electronic trip on protection units\u003c\/li\u003e\n\u003cli\u003ePlug-on bus connection with no mounting hardware\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, tandem two-circuit, 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V standard, tandem, and 2-pole units; AFCI, GFCI, and dual function units rated 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic (standard, tandem, 2-pole); electronic (AFCI, GFCI, dual function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, AFCI, GFCI, dual function AF\/GF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePigtail or plug-on neutral on AFCI and dual function levels, per variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne breaker per unit, configuration and protection level per selected variant\u003c\/li\u003e\n\u003cli\u003ePigtail versions include their factory neutral pigtail; plug-on neutral versions include the neutral foot hardware\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eAFCI, GFCI, and dual function locations follow the NEC edition adopted in your jurisdiction\u003c\/li\u003e\n\u003cli\u003eTandem units go only in slots the panel label permits\u003c\/li\u003e\n\u003cli\u003ePlug-on neutral versions require a load center with a plug-on neutral bus; pigtail versions land on the neutral bar\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePigtail or plug-on neutral, which do I pick?\u003c\/strong\u003e\u003cbr\u003eMatch the panel. Load centers with a plug-on neutral bus take the plug-on neutral versions and skip the pigtail entirely; any other compatible 1 in. plug-on panel takes the pigtail versions. The trade desk checks this against your panel at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I use the tandem unit anywhere in the panel?\u003c\/strong\u003e\u003cbr\u003eNo. Tandem units belong only in slots the panel label lists as tandem-permitted. The panel schedule is checked at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich protection level do I need?\u003c\/strong\u003e\u003cbr\u003eStandard units cover general branch circuits. The NEC calls for AFCI protection in most dwelling living areas, GFCI protection in wet and damp locations, and dual function units where one circuit needs both. Your electrician and the trade desk confirm the schedule at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-CTDL-submittal_d99ca12a-694f-49fd-a4a2-89caad66da20.pdf?v=1783446616\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-CTDL-dimensional_3bf3f319-0b7c-4a66-bbee-9e9976667ba2.pdf?v=1783446616\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-CTDL-install-warranty_028c9fc4-8565-405e-84f8-e836116d3230.pdf?v=1783446616\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Single-Pole \/ Standard","offer_id":48943861563648,"sku":"LA-LGT-BRK-A20-CTDL-STD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Tandem Two Circuit \/ Standard","offer_id":48943861596416,"sku":"LA-LGT-BRK-A20-CTDL-TDM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2-Pole \/ Standard","offer_id":48943861629184,"sku":"LA-LGT-BRK-A20-CTDL-2P","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ AFCI","offer_id":48943861661952,"sku":"LA-LGT-BRK-A20-CTDL-AFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ AFCI Plug-On Neutral","offer_id":48943861694720,"sku":"LA-LGT-BRK-A20-CTDL-PAF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ GFCI","offer_id":48943861727488,"sku":"LA-LGT-BRK-A20-CTDL-GFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ Dual Function AF GF","offer_id":48943861760256,"sku":"LA-LGT-BRK-A20-CTDL-DFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ Dual Function AF GF Plug-On Neutral","offer_id":48943861793024,"sku":"LA-LGT-BRK-A20-CTDL-PDF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38533711167744.png?v=1783443821"},{"product_id":"light-archon-garrison-20a-circuit-breaker-assortment-3-pack","title":"Light Archon Garrison 20A Circuit Breaker Assortment 3-Pack","description":"\u003cp\u003eThe Light Archon Garrison assortment packs the common 20 A starter set into one line item: one single-pole unit for a 120V branch circuit and two 2-pole units for 240V circuits, all in the industry-standard 1 in. plug-on format. It is a practical stock pack for panel work where the schedule calls for a mix. Quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eAll three units are standard thermal magnetic breakers protecting against overloads and short circuits at 20 A. The single-pole unit serves a 120V branch circuit in one pole space; each 2-pole unit serves a 240V circuit across two pole spaces with a common trip. They land on the bus with a plug-on connection and suit residential and single-phase light commercial panels. Pack counts scale at quote review when the project needs more than one assortment.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pack assortment: one single-pole and two 2-pole 20 A units\u003c\/li\u003e\n\u003cli\u003e1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003e120\/240V standard thermal magnetic protection\u003c\/li\u003e\n\u003cli\u003eCovers a 120V branch plus two 240V circuits in one line item\u003c\/li\u003e\n\u003cli\u003ePlug-on bus connection with no mounting hardware\u003c\/li\u003e\n\u003cli\u003eResidential and single-phase light commercial service\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A, all three units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Contents\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne single-pole unit, two 2-pole units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA series class value, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormat\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 in. plug-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload and short-circuit protection, residential and single-phase light commercial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne 20 A single-pole breaker\u003c\/li\u003e\n\u003cli\u003eTwo 20 A 2-pole breakers\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eEach 2-pole unit takes two adjacent pole spaces; the single-pole unit takes one\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat circuits does the assortment cover?\u003c\/strong\u003e\u003cbr\u003eOne 120V branch circuit off the single-pole unit and two 240V circuits off the 2-pole units, all at 20 A. Your electrician matches each unit to conductor size and load per the NEC.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I get different counts?\u003c\/strong\u003e\u003cbr\u003eYes. The 3-pack is the stock assortment; project counts and mixed-amp schedules are built at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-GRSN-submittal_bae37034-4452-4d5a-822f-b56ce7014c14.pdf?v=1783456105\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-GRSN-dimensional_2029f844-d030-436e-ad43-27102715b814.pdf?v=1783456105\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-GRSN-install-warranty_7faa9605-d5bd-4900-a5d1-f9ad3ef59bf6.pdf?v=1783456105\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Default Title","offer_id":48943861924096,"sku":"LA-LGT-BRK-A20-GRSN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38533711659264.png?v=1783455713"},{"product_id":"light-archon-keystone-30a-2-pole-circuit-breaker","title":"Light Archon Keystone 30A 2-Pole Circuit Breaker","description":"\u003cp\u003eThe Light Archon Keystone 30A 2-pole breaker serves 240V appliance circuits in the industry-standard 1 in. plug-on format, taking two pole spaces. It is the platform for water heaters, dryer circuits sized at 30 A, and similar double-pole loads. Quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eThe thermal magnetic trip unit trips to the center position, so a faulted handle reads at a glance during panel checks. Tin-plated copper stabs make a corrosion-resistant plug-on bus connection, box type terminals seat conductors squarely, and the calibration screw is cemented at the factory so the trip point cannot shift in service. The case is heat-resistant thermoset for structural stability, and interrupt rating is 10 kA at 240V.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e30 A 2-pole unit in the 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003e240V rating for appliance and equipment circuits\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip unit; trips to center for clear fault indication\u003c\/li\u003e\n\u003cli\u003eTin-plated copper stabs for a corrosion-resistant bus connection\u003c\/li\u003e\n\u003cli\u003eCemented calibration screw locks the factory trip point\u003c\/li\u003e\n\u003cli\u003eHeat-resistant thermoset case\u003c\/li\u003e\n\u003cli\u003eUL Listed, CSA Listed, and ANSI certified; meets NEMA standards\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole, 1 in. format, two pole spaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic, trips to center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection, tin-plated copper stabs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBox type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat-resistant thermoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Listed, ANSI certified; meets NEMA standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eOne 30 A 2-pole breaker per unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eTakes two adjacent pole spaces on the panel bus\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat circuits is a 30 A 2-pole breaker for?\u003c\/strong\u003e\u003cbr\u003e240V circuits sized at 30 A, such as water heaters and standard electric dryer circuits. Your electrician sizes the breaker to the conductor and the connected load per the NEC.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow many panel spaces does it take?\u003c\/strong\u003e\u003cbr\u003eTwo adjacent pole spaces in a 1 in. format load center; both poles trip together on a common trip bar.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A30-KYSTN-submittal_c9a01a52-4ddf-469f-a197-661607d6a6b1.pdf?v=1783456111\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A30-KYSTN-dimensional_df3b8b6f-1dcf-455c-a1b2-c3e8648f9dc7.pdf?v=1783456111\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A30-KYSTN-install-warranty_e44e985e-2b96-4804-ba33-ed63c2c301dc.pdf?v=1783456111\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Default Title","offer_id":48943861989632,"sku":"LA-LGT-BRK-A30-KYSTN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38533712118016.png?v=1783455718"},{"product_id":"light-archon-redoubt-40a-2-pole-circuit-breaker","title":"Light Archon Redoubt 40A 2-Pole Circuit Breaker","description":"\u003cp\u003eLight Archon Redoubt breakers put the 40 A double-pole slot on one platform in the industry-standard 1 in. plug-on format. Pick the standard thermal magnetic unit for 240V appliance circuits or the GFCI unit where the plan calls for Class A ground fault protection on the full circuit, such as spa and hot tub feeds. Quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eThe standard unit is a thermal magnetic 2-pole breaker with a common trip across both poles. The GFCI unit adds electronic ground fault sensing with a test button on the face and lands its factory pigtail on the panel neutral bar; it protects the entire downstream circuit, which is what the NEC asks of equipment like pools, spas, and hot tubs. Both units connect plug-on to the bus, occupy two pole spaces, and carry a 10 kA interrupt rating at 120\/240V.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e40 A 2-pole platform in the 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003eStandard and GFCI protection levels\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating at 120\/240V\u003c\/li\u003e\n\u003cli\u003eGFCI unit provides Class A ground fault protection for the full circuit\u003c\/li\u003e\n\u003cli\u003eCommon trip across both poles\u003c\/li\u003e\n\u003cli\u003ePlug-on bus connection with no mounting hardware\u003c\/li\u003e\n\u003cli\u003eTwo pole spaces in compatible load centers\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole, 1 in. format, two pole spaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic standard unit; electronic on GFCI unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, GFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGFCI unit ships with a factory neutral pigtail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne 40 A 2-pole breaker per unit, protection level per selected variant\u003c\/li\u003e\n\u003cli\u003eGFCI unit includes its factory neutral pigtail\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eGFCI protection locations follow the NEC edition adopted in your jurisdiction; spa and hot tub circuits commonly require it\u003c\/li\u003e\n\u003cli\u003eLand the GFCI unit pigtail on the panel neutral bar\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhen do I need the GFCI unit?\u003c\/strong\u003e\u003cbr\u003eWhere the NEC requires ground fault protection on a 240V circuit, most commonly spa, hot tub, and pool equipment feeds. The standard unit covers ordinary appliance circuits. Your electrician confirms the requirement for your jurisdiction at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the GFCI unit protect the whole circuit?\u003c\/strong\u003e\u003cbr\u003eYes. Breaker-level GFCI protection covers the entire downstream circuit including the wiring run, not just a single outlet location.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A40-RDBT-submittal_09059284-0988-4b10-8410-86981c1fd8b9.pdf?v=1783456119\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A40-RDBT-dimensional_0188e2cc-5e95-438f-9419-fc61ca1d93fa.pdf?v=1783456120\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A40-RDBT-install-warranty_97e368c6-2f45-4aa0-92f4-057d00c285ec.pdf?v=1783456119\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Standard","offer_id":48943862022400,"sku":"LA-LGT-BRK-A40-RDBT-STD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"GFCI","offer_id":48943862055168,"sku":"LA-LGT-BRK-A40-RDBT-GFC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38533712314624.png?v=1783455735"},{"product_id":"light-archon-outpost-70a-compact-main-lug-load-center","title":"Light Archon Outpost 70A 2-Space Main Lug Load Center","description":"\u003cp\u003eLight Archon Outpost is the small panel for small feeds: a 70A 2-space 4-circuit main lug load center for pool and spa equipment, minisplit condensers, well pumps, gate gear, and detached utility loads. Quote the rainproof outdoor unit or the indoor surface-mount version.\u003c\/p\u003e\u003cp\u003eMain feeders terminate from the top and branch feeders enter from any direction through knockouts on all sides, so the little tub lands cleanly next to the equipment it serves. The outdoor cover is rainproof with a stainless steel hasp that takes a padlock, and the thermoplastic interior is among the most rugged in the class per the published listing. Rated 120\/240V with a 10 kA interrupt rating; fed and protected from an upstream breaker sized per NEC.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e70A main lug platform, 2 spaces, 4 circuits with tandem-style formats\u003c\/li\u003e\n\u003cli\u003eOutdoor NEMA 3R and indoor NEMA 1 configurations\u003c\/li\u003e\n\u003cli\u003eRainproof outdoor cover with padlockable stainless steel hasp\u003c\/li\u003e\n\u003cli\u003eKnockouts on all sides ease feeder routing\u003c\/li\u003e\n\u003cli\u003eTop-terminating main feeders; branch entry from any direction\u003c\/li\u003e\n\u003cli\u003eAccommodates a plug-on secondary surge arrestor, quoted separately\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating; 120\/240V single phase\u003c\/li\u003e\n\u003cli\u003eUL Listed; quote-first trade supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain lug, fixed interior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 spaces, 4 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel; NEMA 3R outdoor or NEMA 1 indoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSurface mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMains terminate from the top; entries on all sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePadlockable stainless hasp on the outdoor cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts Light Archon Aegis and Talos series 1 in. plug-on breakers and industry-standard 1 in. formats - verified at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure with cover, NEMA rated per configuration\u003c\/li\u003e\n\u003cli\u003eMain lug interior; branch breakers quoted separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFed from an upstream breaker sized per NEC; the main lug interior has no main device.\u003c\/li\u003e\n\u003cli\u003eSurface mount beside the served equipment with NEC working clearance at the face.\u003c\/li\u003e\n\u003cli\u003eMains terminate from the top; the device cannot be rotated, so plan the feeder drop accordingly.\u003c\/li\u003e\n\u003cli\u003eBond and ground per NEC; separate grounded and bonding conductors in subpanel use.\u003c\/li\u003e\n\u003cli\u003eBranch breaker schedule and any surge arrestor are confirmed at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat loads suit a 2-space panel?\u003c\/strong\u003e\u003cbr\u003ePool and spa packs, minisplit condensers, well pumps, and detached utility feeds: anywhere one or two circuits need local distribution and disconnect-adjacent protection sized per NEC.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it have a main breaker?\u003c\/strong\u003e\u003cbr\u003eNo. It is a main lug panel protected by the upstream feeder breaker. Quote a main-breaker platform when the location needs its own main device.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it mount outdoors?\u003c\/strong\u003e\u003cbr\u003eYes. The outdoor configuration is NEMA 3R rainproof with a padlockable stainless steel hasp. The indoor version is a NEMA 1 surface-mount tub.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat breakers does it accept?\u003c\/strong\u003e\u003cbr\u003eLight Archon Aegis and Talos series 1 in. plug-on breakers and industry-standard 1 in. formats, verified at quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S2-OTPS-submittal_20f95404-d165-432c-a9cd-ebe8f16c2834.pdf?v=1783456125\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S2-OTPS-dimensional_173dee8c-a566-42d0-bf89-298b109ce607.pdf?v=1783456125\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S2-OTPS-install-warranty_8a17625b-83e7-4929-ac4c-4004f339ecc0.pdf?v=1783456125\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Outdoor NEMA 3R","offer_id":48943868805376,"sku":"LA-LGT-LC-S2-OTPS-2OR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Indoor Surface Mount","offer_id":48943868838144,"sku":"LA-LGT-LC-S2-OTPS-2IS","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38533721227520.png?v=1783455757"},{"product_id":"light-archon-cornerstone-100a-load-center","title":"Light Archon Cornerstone 100A Load Center","description":"\u003cp\u003eLight Archon Cornerstone load centers cover the 100A tier from whole-dwelling service in smaller homes to garage, shop, and addition subpanels. Main breaker configurations run 8 to 30 spaces with a plug-on neutral bus; compact 6-space main lug units handle small subfeeds indoors, outdoors, and flush-mounted. Quote-first: the desk confirms configuration and breaker schedule before release.\u003c\/p\u003e\u003cp\u003eMain breaker units carry a fully distributed neutral so combination arc fault breakers plug on at any space per the published listing, with straight-in mains and a rotating interior for overhead or underground feed. Value packs add a starter assortment of branch breakers, itemized at quote review. The 6-space main lug units are the compact panels for pools, sheds, and HVAC subfeeds: surface, flush, or NEMA 3R outdoor. The rep-verified interrupt rating is 22 kA, confirmed per configuration at quote review.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e100A platform from 6-space main lug to 30-space main breaker\u003c\/li\u003e\n\u003cli\u003ePlug-on neutral bus on main breaker configurations\u003c\/li\u003e\n\u003cli\u003eValue packs include a branch breaker assortment, itemized at quote review\u003c\/li\u003e\n\u003cli\u003eSpeed-terminal value pack cuts neutral landing time per the published listing\u003c\/li\u003e\n\u003cli\u003eCompact 6-space main lug units: indoor surface, indoor flush, or outdoor NEMA 3R\u003c\/li\u003e\n\u003cli\u003eOverhead or underground feed by rotating the interior\u003c\/li\u003e\n\u003cli\u003eRugged thermoplastic interior; removable for jobsite protection per the published listing\u003c\/li\u003e\n\u003cli\u003e22 kA rep-verified interrupt rating; UL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V, single phase, 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 to 30 spaces, 12 to 60 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMain Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain breaker; main lug on 6-space units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on neutral on main breaker units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 kA rep-verified, per configuration at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel; NEMA 1 indoor, NEMA 3R outdoor main lug unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlush or surface by configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverhead or underground, rotating interior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts Light Archon Aegis and Talos series 1 in. plug-on breakers and industry-standard 1 in. formats - verified at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain device per configuration; branch assortment on value packs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure with cover per configuration (flush 6-space unit ships without a door)\u003c\/li\u003e\n\u003cli\u003eFactory-installed 100A main breaker on main breaker configurations\u003c\/li\u003e\n\u003cli\u003eBranch breaker assortment on value pack configurations, itemized at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician as service equipment or subpanel per plan.\u003c\/li\u003e\n\u003cli\u003eMain lug units are fed from an upstream breaker sized per NEC; separate grounded and bonding conductors in subpanel use.\u003c\/li\u003e\n\u003cli\u003eKeep NEC working clearance at the enclosure face; flush units finish tight to drywall.\u003c\/li\u003e\n\u003cli\u003eRotate the interior for overhead or underground feed before conductor landing.\u003c\/li\u003e\n\u003cli\u003eBranch breaker schedules are finalized at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat breakers does it accept?\u003c\/strong\u003e\u003cbr\u003eLight Archon Aegis and Talos series 1 in. plug-on branch breakers and industry-standard 1 in. formats; the schedule is verified at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich configuration for a garage subpanel?\u003c\/strong\u003e\u003cbr\u003eThe 6-space main lug units cover small subfeeds; step to the 8-space or 20-space main breaker units when the circuit count or a local disconnect requirement calls for it. The desk sizes it from your load list.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the main breaker included?\u003c\/strong\u003e\u003cbr\u003eMain breaker configurations ship with the 100A main factory installed. Main lug units have no main device and are protected by the upstream feeder breaker.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan any unit mount outdoors?\u003c\/strong\u003e\u003cbr\u003eThe 6-space main lug outdoor unit carries a NEMA 3R enclosure. The remaining configurations are NEMA 1 indoor panels.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S20-CRNST-submittal_ecf3d4a5-7544-4d99-a72e-8841804822e9.pdf?v=1783456134\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S20-CRNST-dimensional_661f4452-619f-4ff3-85fb-4f7bc5291ca3.pdf?v=1783456134\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S20-CRNST-install-warranty_01b50fc6-f863-4767-a7ba-a95224d535cc.pdf?v=1783456134\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"20-Space 40-Circuit Main Breaker Value Pack","offer_id":48943869067520,"sku":"LA-LGT-LC-S20-CRNST-20MBVP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20-Space 40-Circuit Main Breaker Speed-Terminal Value Pack","offer_id":48943869100288,"sku":"LA-LGT-LC-S20-CRNST-20MBQVP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"20-Space 40-Circuit Main Breaker","offer_id":48943869133056,"sku":"LA-LGT-LC-S20-CRNST-20MB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"24-Space 48-Circuit Main Breaker Value Pack","offer_id":48943869165824,"sku":"LA-LGT-LC-S20-CRNST-24MBVP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"30-Space 60-Circuit Main Breaker","offer_id":48943869198592,"sku":"LA-LGT-LC-S20-CRNST-30MB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8-Space 16-Circuit Main Breaker","offer_id":48943869231360,"sku":"LA-LGT-LC-S20-CRNST-08MB","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6-Space 12-Circuit Main Lug Outdoor","offer_id":48943869264128,"sku":"LA-LGT-LC-S20-CRNST-06MLO","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6-Space 12-Circuit Main Lug Indoor Surface","offer_id":48943869296896,"sku":"LA-LGT-LC-S20-CRNST-06MLI","price":0.0,"currency_code":"USD","in_stock":true},{"title":"6-Space 12-Circuit Main Lug Indoor Flush, No Door","offer_id":48943869329664,"sku":"LA-LGT-LC-S20-CRNST-06MLF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38533721358592.png?v=1783455746"},{"product_id":"light-archon-mainstay-200a-plug-on-neutral-load-center","title":"Light Archon Mainstay 200A Plug-On Neutral Load Center","description":"\u003cp\u003eLight Archon Mainstay load centers anchor 200A services with a plug-on neutral bus and the space counts bigger houses actually need: 30-space and 40-space configurations indoor and outdoor, value packs with branch breaker assortments, surge-device versions, and a compact 8-space outdoor unit with feed-through lugs for downstream panels. Quote-first: the trade desk confirms the configuration and breaker schedule before release.\u003c\/p\u003e\u003cp\u003eThe fully distributed neutral bar means combination arc fault breakers plug on at any space, with no pigtail management per the published listing. Straight-in mains save cable, the cover self-adjusts for flush finishes on indoor units, and the interior rotates for overhead or underground feed. Ground and neutral bars accept up to three 10-14 equipment grounds per termination, and the distributed split branch neutral carries up to half again more terminals than the baseline standard requires per the published listing. The rep-verified interrupt rating is 22 kA, confirmed per configuration at quote review.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e200A plug-on neutral platform, 8 to 40 spaces, 16 to 80 circuits\u003c\/li\u003e\n\u003cli\u003eFactory-installed main breaker on every configuration\u003c\/li\u003e\n\u003cli\u003eFully distributed neutral: arc fault breakers land on any space\u003c\/li\u003e\n\u003cli\u003eValue packs include a branch breaker assortment, itemized at quote review\u003c\/li\u003e\n\u003cli\u003eSurge-device configurations add whole-panel surge protection\u003c\/li\u003e\n\u003cli\u003eSpeed-terminal configurations cut neutral landing time per the published listing\u003c\/li\u003e\n\u003cli\u003eFeed-through 8-space outdoor unit feeds downstream panels\u003c\/li\u003e\n\u003cli\u003eOverhead or underground feed by rotating the interior\u003c\/li\u003e\n\u003cli\u003e22 kA rep-verified interrupt rating; UL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V, single phase, 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 to 40 spaces, 16 to 80 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on neutral, fully distributed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 kA rep-verified, per configuration at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel; NEMA 1 indoor or NEMA 3R outdoor by configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlush or surface indoor; surface outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverhead or underground, rotating interior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaker Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccepts Light Archon Aegis and Talos series 1 in. plug-on breakers and industry-standard 1 in. formats - verified at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMain breaker factory installed; branch assortment on value packs; surge device on SPD versions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to three 10-14 equipment grounds per bar termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnclosure with cover, NEMA rated per configuration\u003c\/li\u003e\n\u003cli\u003eFactory-installed 200A main breaker\u003c\/li\u003e\n\u003cli\u003eBranch breaker assortment on value pack configurations, itemized at quote review\u003c\/li\u003e\n\u003cli\u003ePlug-on surge protection device on SPD configurations\u003c\/li\u003e\n\u003cli\u003eFeed-through lugs on the 8-space outdoor configuration\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician as service equipment or subpanel per plan.\u003c\/li\u003e\n\u003cli\u003eKeep NEC working clearance at the enclosure face; flush or surface mount per configuration.\u003c\/li\u003e\n\u003cli\u003eBond and ground per NEC; separate grounded and bonding conductors in subpanel use.\u003c\/li\u003e\n\u003cli\u003eRotate the interior for overhead or underground feed before conductor landing.\u003c\/li\u003e\n\u003cli\u003eBranch breaker schedule and surge device placement are finalized at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat breakers does it accept?\u003c\/strong\u003e\u003cbr\u003eLight Archon Aegis and Talos series 1 in. plug-on branch breakers and industry-standard 1 in. formats; the exact schedule for your job is verified at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat comes in a value pack?\u003c\/strong\u003e\u003cbr\u003eThe enclosure, cover, factory-installed 200A main breaker, and an assortment of single-pole and double-pole branch breakers. The assortment is itemized at quote review since it varies by configuration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich configurations mount outdoors?\u003c\/strong\u003e\u003cbr\u003eThe 30-space outdoor value packs and the 8-space feed-through unit carry NEMA 3R enclosures. Indoor units are NEMA 1 with flush or surface mounting.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does the surge device configuration add?\u003c\/strong\u003e\u003cbr\u003eA factory-fitted plug-on surge protection device covering the whole panel, on the 30-space outdoor and 40-space indoor versions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it feed a detached building?\u003c\/strong\u003e\u003cbr\u003eThe 8-space outdoor unit carries feed-through lugs sized for downstream panels, which is the clean way to chain a garage or shop panel. Conductor sizing is confirmed at quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S30-MNSTY-submittal_33f13468-8d79-4ca2-88fd-019ac71800f4.pdf?v=1783446642\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S30-MNSTY-dimensional_383c7402-55c7-4c86-8d49-e3fc62d0b29e.pdf?v=1783446642\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-LC-S30-MNSTY-install-warranty_fc54aa0e-ba81-414a-9bb7-8d58d2e576a8.pdf?v=1783446642\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"30-Space 60-Circuit Indoor Value Pack","offer_id":48943869427968,"sku":"LA-LGT-LC-S30-MNSTY-30IVP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"30-Space 60-Circuit Indoor Speed-Terminal Value Pack","offer_id":48943869460736,"sku":"LA-LGT-LC-S30-MNSTY-30IQVP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"30-Space 60-Circuit Outdoor Value Pack","offer_id":48943869493504,"sku":"LA-LGT-LC-S30-MNSTY-30OVP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"30-Space 60-Circuit Outdoor Value Pack with Surge Device","offer_id":48943869526272,"sku":"LA-LGT-LC-S30-MNSTY-30OSPD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"40-Space 80-Circuit Indoor Value Pack with Branch Breakers","offer_id":48943869559040,"sku":"LA-LGT-LC-S30-MNSTY-40IVP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"40-Space 80-Circuit Indoor Speed-Terminal Value Pack","offer_id":48943869591808,"sku":"LA-LGT-LC-S30-MNSTY-40IQVP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"40-Space 80-Circuit Indoor Value Pack with Surge Device","offer_id":48943869624576,"sku":"LA-LGT-LC-S30-MNSTY-40ISPD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"8-Space 16-Circuit Outdoor with Feed-Through Lugs","offer_id":48943869657344,"sku":"LA-LGT-LC-S30-MNSTY-08OFT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38533721522432.png?v=1783443850"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/collections\/breakers-and-load-centers.png?v=1783313475","url":"https:\/\/ironcinder.com\/collections\/breakers-and-load-centers\/install_plug-on.oembed","provider":"IronCinder","version":"1.0","type":"link"}