{"title":"Conduit and Fittings","description":"\u003cp\u003eEMT and PVC conduit with the sweeps, connectors, and couplings to complete every run. Common trade sizes for branch, feeder, and service work. Bundle quantities quoted from your conduit schedule.\u003c\/p\u003e","products":[{"product_id":"light-archon-duraduct-pvc-schedule-40-conduit","title":"Light Archon DuraDuct PVC Schedule 40 Conduit","description":"\u003cp\u003eLight Archon DuraDuct schedule 40 PVC conduit runs interior, exterior, and underground raceway where corrosion and moisture rule out steel. Seven trade sizes quote in 10 ft sticks.\u003c\/p\u003e\u003cp\u003eSunlight resistant rigid nonmetallic conduit conforms to UL 651 and NEMA TC-2 per the published listing and is rated for conductors to 90 C. Solvent-weld joints assemble fast with schedule 40 fittings, and the FlowLine fitting set covers elbows, access bodies, and liquidtight transitions.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSchedule 40 rigid nonmetallic conduit, UL 651 and NEMA TC-2 class\u003c\/li\u003e\n\u003cli\u003eTrade sizes 1\/2 through 2-1\/2 in. in 10 ft sticks\u003c\/li\u003e\n\u003cli\u003eSunlight resistant for exposed exterior runs\u003c\/li\u003e\n\u003cli\u003eRated for conductors to 90 C per the published listing\u003c\/li\u003e\n\u003cli\u003eSolvent-weld assembly with schedule 40 fittings\u003c\/li\u003e\n\u003cli\u003eNonconductive and corrosion-proof for wet and buried routes\u003c\/li\u003e\n\u003cli\u003ePairs with the FlowLine PVC fitting set for elbows and access bodies\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRigid nonmetallic conduit, schedule 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, sunlight resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrade sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4, 1, 1-1\/4, 1-1\/2, 2, 2-1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStick length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductors to 90 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 651, NEMA TC-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolvent-weld sockets and fittings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterior, exterior, and underground where code permits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 in. stick listed at 2.25 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first; bundle counts welcome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eConduit sticks only; fittings, cement, and primer quoted separately\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCut square, de-burr, and dry-fit before cement goes on.\u003c\/li\u003e\n\u003cli\u003eUse listed PVC primer and cement rated for electrical conduit.\u003c\/li\u003e\n\u003cli\u003eUnderground depth and cover follow NEC and local code; confirm the route at quote review.\u003c\/li\u003e\n\u003cli\u003eAllow for thermal expansion on continuous exposed runs with expansion fittings where the run length demands it.\u003c\/li\u003e\n\u003cli\u003eSchedule 80 heavy-wall sticks quote on request for exposure-prone locations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat fittings does it take?\u003c\/strong\u003e\u003cbr\u003eSolvent-weld schedule 40 PVC fittings: couplings, belled-end elbows, and access bodies. The FlowLine set covers the common formats and quotes with the conduit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be buried?\u003c\/strong\u003e\u003cbr\u003eSchedule 40 PVC conduit is used underground where code permits. Depth and cover per NEC and local rules are confirmed at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it sunlight resistant?\u003c\/strong\u003e\u003cbr\u003eYes. The compound is sunlight resistant for exposed exterior runs per the published listing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo you carry schedule 80?\u003c\/strong\u003e\u003cbr\u003eHeavy-wall schedule 80 sticks quote on request where added impact protection is called for.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-C34-DDCT-submittal.pdf?v=1783306822\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-C34-DDCT-dimensional.pdf?v=1783306822\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-C34-DDCT-install-warranty.pdf?v=1783306822\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"1\/2 in.","offer_id":48934491750656,"sku":"LA-LGT-CN-C34-DDCT-12","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/4 in.","offer_id":48934491783424,"sku":"LA-LGT-CN-C34-DDCT-34","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1 in.","offer_id":48934491816192,"sku":"LA-LGT-CN-C34-DDCT-1","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1-1\/4 in.","offer_id":48934491848960,"sku":"LA-LGT-CN-C34-DDCT-114","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 in.","offer_id":48934491881728,"sku":"LA-LGT-CN-C34-DDCT-112","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2 in.","offer_id":48934491914496,"sku":"LA-LGT-CN-C34-DDCT-2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2-1\/2 in.","offer_id":48934491947264,"sku":"LA-LGT-CN-C34-DDCT-212","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_1690983b-c129-4735-9eea-1d343e40f8ec.png?v=1783306404"},{"product_id":"light-archon-steelpath-emt-conduit-galvanized-steel","title":"Light Archon SteelPath EMT Conduit, Galvanized Steel","description":"\u003cp\u003eLight Archon SteelPath EMT is the thin-wall galvanized steel raceway for exposed and concealed runs in commercial and residential work. Sticks quote in five trade sizes, with 5 ft cuts in the two smallest sizes.\u003c\/p\u003e\u003cp\u003eUnthreaded galvanized steel takes set-screw and compression fittings, bends cleanly with a standard bender in the smaller sizes, and serves as the equipment ground path when assembled with listed fittings per NEC. A smooth interior coating protects conductors on the pull. UL 797 class per the published listing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGalvanized steel thin-wall raceway, UL 797 class\u003c\/li\u003e\n\u003cli\u003eTrade sizes 1\/2 through 2 in.; 10 ft sticks with 5 ft cuts in 1\/2 and 3\/4 in.\u003c\/li\u003e\n\u003cli\u003eServes as the equipment ground path with listed fittings per NEC\u003c\/li\u003e\n\u003cli\u003eSmooth interior coating eases conductor pulls\u003c\/li\u003e\n\u003cli\u003eBends with standard hand and power benders in the smaller sizes\u003c\/li\u003e\n\u003cli\u003eExposed or concealed, interior or exterior with raintight fittings\u003c\/li\u003e\n\u003cli\u003eQuote-first supply with bundle counts for production jobs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEMT thin-wall raceway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanized steel, unthreaded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrade sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4, 1-1\/4, 1-1\/2, 2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStick lengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ft standard; 5 ft in 1\/2 and 3\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSmooth coated raceway for easy pulls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFittings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSet-screw and compression; raintight compression outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEquipment ground with listed fittings per NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 797 class; CSA listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExposed or concealed, interior or exterior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 in. by 10 ft stick listed at 4.6 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first; bundle counts welcome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eConduit sticks only; fittings and straps quoted separately\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eReam cut ends before conductors go in.\u003c\/li\u003e\n\u003cli\u003eUse raintight compression fittings on exterior runs.\u003c\/li\u003e\n\u003cli\u003eStrap and support per NEC spacing for the trade size.\u003c\/li\u003e\n\u003cli\u003eField bends need the correct bender shoe per size; factory sweeps quote on request.\u003c\/li\u003e\n\u003cli\u003eFitting types and counts are confirmed at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat fittings does it take?\u003c\/strong\u003e\u003cbr\u003eSet-screw and compression EMT fittings in matching trade sizes. Use raintight compression fittings outdoors. Fitting counts are quoted with the conduit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan EMT serve as the ground path?\u003c\/strong\u003e\u003cbr\u003eYes. Assembled with listed fittings and installed per NEC, it serves as an equipment ground path.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo you stock 1 in. EMT?\u003c\/strong\u003e\u003cbr\u003eThe quoted size run covers 1\/2 through 2 in. as listed; 1 in. sticks are quoted on request through the desk.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAre 5 ft sticks available?\u003c\/strong\u003e\u003cbr\u003eYes, in 1\/2 and 3\/4 in. for tight van stock and small punch lists.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-C34-STLP-submittal.pdf?v=1783306827\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-C34-STLP-dimensional.pdf?v=1783306827\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-C34-STLP-install-warranty.pdf?v=1783306827\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"1\/2 in. \/ 5 ft","offer_id":48934492012800,"sku":"LA-LGT-CN-C34-STLP-12X5","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/2 in. \/ 10 ft","offer_id":48934492045568,"sku":"LA-LGT-CN-C34-STLP-12X10","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/4 in. \/ 5 ft","offer_id":48934492078336,"sku":"LA-LGT-CN-C34-STLP-34X5","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/4 in. \/ 10 ft","offer_id":48934492111104,"sku":"LA-LGT-CN-C34-STLP-34X10","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1-1\/4 in. \/ 10 ft","offer_id":48934492143872,"sku":"LA-LGT-CN-C34-STLP-114X10","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 in. \/ 10 ft","offer_id":48934492176640,"sku":"LA-LGT-CN-C34-STLP-112X10","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2 in. \/ 10 ft","offer_id":48934492209408,"sku":"LA-LGT-CN-C34-STLP-2X10","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_df91e628-ea7b-471e-bd1c-a28c14b3930b.png?v=1783306406"},{"product_id":"light-archon-tightseal-liquidtight-nonmetallic-conduit-connector-1-2-in","title":"Light Archon TightSeal Liquidtight Nonmetallic Conduit Connector, 1\/2 in.","description":"\u003cp\u003eLight Archon TightSeal is a 1\/2 in. straight connector that lands flexible nonmetallic liquidtight conduit on boxes and enclosures. Quote singles for punch work or 5-packs for production runs.\u003c\/p\u003e\u003cp\u003eThe PVC body sheds rain, liquids, and oils, and every connector includes a steel locknut and seal gasket. Assembly is hand-tight simple with no special tools. UL listed and CSA certified per the published listing for interior and exterior work.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStraight 1\/2 in. connector for flexible nonmetallic liquidtight conduit\u003c\/li\u003e\n\u003cli\u003eSteel locknut and seal gasket included with every connector\u003c\/li\u003e\n\u003cli\u003eSheds rain, liquids, and oils on exterior runs\u003c\/li\u003e\n\u003cli\u003eTool-free hand-tight assembly\u003c\/li\u003e\n\u003cli\u003eUL listed and CSA certified per the published listing\u003c\/li\u003e\n\u003cli\u003eSingle and 5-pack counts on one quote\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight liquidtight connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrade size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC body, steel locknut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGasket included per connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.7 in. per the published listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCounts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle or 5-pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL listed, CSA certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterior and exterior runs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJoins\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible nonmetallic liquidtight conduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first; bulk counts welcome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eConnector body, steel locknut, and seal gasket per unit\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSeat the gasket square before the locknut goes on.\u003c\/li\u003e\n\u003cli\u003eUse with flexible nonmetallic liquidtight conduit in the matching trade size.\u003c\/li\u003e\n\u003cli\u003eKeep exterior penetrations sealed per the enclosure listing.\u003c\/li\u003e\n\u003cli\u003eA 1-1\/2 in. size quotes on request for feeder-class flex runs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat conduit does it join?\u003c\/strong\u003e\u003cbr\u003eFlexible nonmetallic liquidtight conduit, 1\/2 in. trade size. It lands the flex on boxes and enclosures with the included locknut.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the hardware included?\u003c\/strong\u003e\u003cbr\u003eYes. Each connector ships with a steel locknut and seal gasket.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I use it outdoors?\u003c\/strong\u003e\u003cbr\u003eYes. The body sheds rain, liquids, and oils and is listed for exterior use per the published listing.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F12-TSEL-submittal.pdf?v=1783306835\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F12-TSEL-dimensional.pdf?v=1783306835\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F12-TSEL-install-warranty.pdf?v=1783306835\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Single","offer_id":48934492373248,"sku":"LA-LGT-CN-F12-TSEL-1PK","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5-Pack","offer_id":48934492406016,"sku":"LA-LGT-CN-F12-TSEL-5PK","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_4040c8ca-3b66-4c6d-8660-c616e49271b4.png?v=1783306410"},{"product_id":"light-archon-flowline-pvc-conduit-fittings-schedule-40","title":"Light Archon FlowLine PVC Conduit Fittings, Schedule 40","description":"\u003cp\u003eLight Archon FlowLine PVC fittings finish schedule 40 raceway runs with standard radius elbows, conduit bodies, and a liquidtight transition. Six formats quote alongside DuraDuct conduit.\u003c\/p\u003e\u003cp\u003eBelled-end 90-deg elbows cement directly to schedule 40 and 80 pipe without separate couplings and keep conductor pulls smooth through the sweep. Type LB and LR conduit bodies turn runs into walls and around corners while adding a covered pull point. The 1\/2 in. liquidtight connector transitions rigid runs to flexible nonmetallic conduit. Third-party listed and NEC rated per the published listing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStandard radius 90-deg belled-end elbows in 3\/4 and 1 in.\u003c\/li\u003e\n\u003cli\u003eBelled ends cement to schedule 40 and 80 pipe without couplings\u003c\/li\u003e\n\u003cli\u003eType LB and LR conduit bodies add covered pull points at turns\u003c\/li\u003e\n\u003cli\u003e1\/2 in. two-piece liquidtight connector for flexible transitions\u003c\/li\u003e\n\u003cli\u003eCorrosion resistant PVC throughout\u003c\/li\u003e\n\u003cli\u003eThird-party listed and NEC rated per the published listing\u003c\/li\u003e\n\u003cli\u003eQuotes bundle with DuraDuct conduit for one submittal\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormats\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90-deg elbows; LB and LR conduit bodies; liquidtight connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElbow sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 in. and 1 in., standard radius, belled end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConduit bodies\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2 and 3\/4 in. LB; 3\/4 in. LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2 in. two-piece straight liquidtight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, schedule 40 class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJoint method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSolvent weld; belled ends seat pipe directly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSchedule 40 and 80 PVC raceway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThird-party listed, NEC rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterior, exterior, and buried runs per code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first with conduit bundles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFitting bodies as quoted; covers and gaskets on conduit bodies per format\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrime and cement joints with listed electrical PVC cement.\u003c\/li\u003e\n\u003cli\u003eConduit body covers stay reachable per NEC; do not bury access points.\u003c\/li\u003e\n\u003cli\u003eKeep conductor fill within the raceway rating through elbows and bodies.\u003c\/li\u003e\n\u003cli\u003eMatch fitting size to conduit trade size; transitions are confirmed at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat conduit do these join?\u003c\/strong\u003e\u003cbr\u003eSchedule 40 and 80 PVC raceway. Belled ends and sockets solvent-weld directly to the pipe, and sizes match trade size for trade size.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat are LB and LR bodies for?\u003c\/strong\u003e\u003cbr\u003eThey turn a run into a wall or around a corner and add a covered pull point where straight pulls would strain conductors.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the liquidtight connector fit metal conduit?\u003c\/strong\u003e\u003cbr\u003eNo. It joins flexible nonmetallic liquidtight conduit to boxes or enclosures in the same trade size.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F34-FLOW-submittal.pdf?v=1783306841\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F34-FLOW-dimensional.pdf?v=1783306841\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F34-FLOW-install-warranty.pdf?v=1783306841\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"3\/4 in. 90-Deg Elbow, Belled End","offer_id":48934492438784,"sku":"LA-LGT-CN-F34-FLOW-E34","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1 in. 90-Deg Elbow, Belled End","offer_id":48934492471552,"sku":"LA-LGT-CN-F34-FLOW-E1","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/2 in. Liquidtight Connector","offer_id":48934492504320,"sku":"LA-LGT-CN-F34-FLOW-LT12","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/2 in. Type LB Conduit Body","offer_id":48934492537088,"sku":"LA-LGT-CN-F34-FLOW-LB12","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/4 in. Type LB Conduit Body","offer_id":48934492569856,"sku":"LA-LGT-CN-F34-FLOW-LB34","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/4 in. Type LR Conduit Body","offer_id":48934492602624,"sku":"LA-LGT-CN-F34-FLOW-LR34","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_899b3565-1039-4d04-8507-689c92608085.png?v=1783306414"},{"product_id":"light-archon-sealpath-liquidtight-conduit-connector-3-4-in","title":"Light Archon SealPath Liquidtight Nonmetallic Conduit Connector, 3\/4 in.","description":"\u003cp\u003eLight Archon SealPath connectors terminate 3\/4 in. liquidtight flexible nonmetallic conduit into boxes, enclosures, and equipment while keeping the wet-location seal intact. Each connector arrives with its steel locknut and seal gasket.\u003c\/p\u003e\u003cp\u003eThe PVC body threads onto the conduit convolutions and compresses the gasket at the enclosure wall, shedding rain, liquids, and oils per the published listing. Assembly is simple and tool-light: seat, tighten, land the locknut. UL listed and CSA certified per the published listing, for interior and exterior runs. Pair it with the FlexShield conduit program quoted alongside.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eStraight liquidtight termination for 3\/4 in. flexible nonmetallic conduit\u003c\/li\u003e\n\u003cli\u003eSteel locknut and seal gasket included\u003c\/li\u003e\n\u003cli\u003eSheds rain, liquids, and oils per the published listing\u003c\/li\u003e\n\u003cli\u003eQuick, tool-light assembly at the enclosure wall\u003c\/li\u003e\n\u003cli\u003eUL listed and CSA certified per the published listing\u003c\/li\u003e\n\u003cli\u003eInterior and exterior use\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply; connector counts ride the conduit quote\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStraight liquidtight connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrade size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel locknut, seal gasket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.65 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRain, liquid, and oil shedding per the published listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL listed, CSA certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInterior and exterior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePairs with\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquidtight flexible nonmetallic conduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first; counts confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eConnector body with steel locknut and seal gasket\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThread the body onto the conduit convolutions until seated, then land and tighten the locknut inside the enclosure.\u003c\/li\u003e\n\u003cli\u003eSeat the gasket flat against the enclosure wall to keep the wet-location seal.\u003c\/li\u003e\n\u003cli\u003eUse one connector per termination; count both ends of every whip and run.\u003c\/li\u003e\n\u003cli\u003eFor metallic liquidtight conduit, quote the matching metallic fitting class instead.\u003c\/li\u003e\n\u003cli\u003eConnector counts are confirmed with the conduit takeoff at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat conduit does this fit?\u003c\/strong\u003e\u003cbr\u003e3\/4 in. liquidtight flexible nonmetallic conduit, including the FlexShield program quoted alongside. It is not for metallic liquidtight or EMT.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the locknut included?\u003c\/strong\u003e\u003cbr\u003eYes. Each connector ships with its steel locknut and seal gasket.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be used outdoors?\u003c\/strong\u003e\u003cbr\u003eYes. It sheds rain, liquids, and oils per the published listing and serves interior and exterior terminations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo you carry other sizes and angles?\u003c\/strong\u003e\u003cbr\u003eThe 1\/2 in. straight connector quotes as the TightSeal series, and 90-degree bodies and other sizes are quoted on request through the desk.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F34-SLPT-submittal.pdf?v=1783373217\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F34-SLPT-dimensional.pdf?v=1783373217\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F34-SLPT-install-warranty.pdf?v=1783373217\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Default Title","offer_id":48943866052864,"sku":"LA-LGT-CN-F34-SLPT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_a75ba238-c576-41ec-884f-9a93a1eb130d.png?v=1783372942"},{"product_id":"light-archon-latchpoint-snap-in-cable-connectors-3-8-in","title":"Light Archon LatchPoint 3\/8 in. Snap-In Cable Connectors, 5-Pack","description":"\u003cp\u003eLight Archon LatchPoint connectors land metal-clad cable in one motion: snap the fitting into the knockout, snap the cable home, done. The 5-pack covers a service loop of 3\/8 in. terminations without a loose-parts bag.\u003c\/p\u003e\u003cp\u003eDie-cast zinc bodies take the abuse of panel work, and the snap-in design removes locknut spinning from every termination, which is where MC-heavy jobs bleed minutes. Connectors suit MC and HCF steel and aluminum cables and are tested and listed to ground-fault requirements per the published listing, keeping the bond path honest through the fitting. UL and CSA listed per the published listing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSnap-in installation: no locknut, one motion per termination\u003c\/li\u003e\n\u003cli\u003eDie-cast zinc bodies stand up to panel and box work\u003c\/li\u003e\n\u003cli\u003eFits MC and HCF steel and aluminum cables per the published listing\u003c\/li\u003e\n\u003cli\u003eTested and listed to ground-fault requirements per the published listing\u003c\/li\u003e\n\u003cli\u003e3\/8 in. trade size, sold in 5-packs\u003c\/li\u003e\n\u003cli\u003eUL and CSA listed per the published listing\u003c\/li\u003e\n\u003cli\u003e50-count contractor packs quoted on request\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSnap-in cable connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrade size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDie-cast zinc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMC and HCF, steel and aluminum armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eListed to ground-fault requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL listed, CSA listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry interior locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContractor packs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50-count quoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first; counts confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFive snap-in connectors per pack\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSnap the connector into a standard knockout, then insert the prepared cable until it latches.\u003c\/li\u003e\n\u003cli\u003eStrip and bush the armor per the cable listing before insertion.\u003c\/li\u003e\n\u003cli\u003eUse one connector per cable entry; count every box and panel landing in the takeoff.\u003c\/li\u003e\n\u003cli\u003eFor wet locations quote liquidtight fittings instead; these are dry-location connectors.\u003c\/li\u003e\n\u003cli\u003ePack counts and 50-count contractor packs are confirmed at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat cables do these fit?\u003c\/strong\u003e\u003cbr\u003eMC and HCF cables with steel or aluminum armor in the 3\/8 in. connector size, per the published listing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is the snap-in faster than a standard connector?\u003c\/strong\u003e\u003cbr\u003eThere is no locknut. The connector snaps into the knockout from outside the box and the cable snaps into the connector, so each termination is two motions with no wrench time inside the enclosure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo they maintain the equipment ground?\u003c\/strong\u003e\u003cbr\u003eYes. The connectors are tested and listed to ground-fault requirements per the published listing, keeping the armor bond path through the fitting.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I get bulk counts?\u003c\/strong\u003e\u003cbr\u003eYes. 50-count contractor packs are quoted on request through the desk.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F38-LTCH-submittal.pdf?v=1783373222\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F38-LTCH-dimensional.pdf?v=1783373222\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-F38-LTCH-install-warranty.pdf?v=1783373222\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Default Title","offer_id":48943866282240,"sku":"LA-LGT-CN-F38-LTCH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_11c659cd-84e0-4762-b2f7-239d0a2675f8.png?v=1783372945"},{"product_id":"light-archon-flexshield-liquidtight-flexible-nonmetallic-conduit","title":"Light Archon FlexShield Liquidtight Flexible Nonmetallic Conduit","description":"\u003cp\u003eLight Archon FlexShield is the liquidtight flexible nonmetallic conduit for condenser whips, pump and motor feeds, rooftop equipment, and any route with vibration, crossover connections, or bends too tight for rigid raceway. Coils quote in three trade sizes.\u003c\/p\u003e\u003cp\u003eFlexible PVC with rigid convolutions gives crush resistance without giving up bend radius, and the liquid-tight wall keeps vapors, solids, and weather off the conductors per the published listing. It suits circuits of 600V nominal or less, including motor feeder, branch, and control work. Terminate with listed liquidtight nonmetallic fittings, quoted alongside, to carry the seal into every enclosure.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLiquidtight flexible nonmetallic construction for wet and weather-exposed routes\u003c\/li\u003e\n\u003cli\u003eCrush-resistant rigid PVC convolutions with full flexibility per the published listing\u003c\/li\u003e\n\u003cli\u003eTrade sizes 1\/2, 3\/4, and 1 in. in job-length coils\u003c\/li\u003e\n\u003cli\u003eSuitable for 600V nominal or less circuits per the published listing\u003c\/li\u003e\n\u003cli\u003eBuilt for movement, vibration, crossover connections, and tight bends\u003c\/li\u003e\n\u003cli\u003eMotor feeder, branch, and control circuit duty\u003c\/li\u003e\n\u003cli\u003eCSA listed per the published listing\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply; fittings quoted with the coil\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquidtight flexible nonmetallic conduit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, flexible with rigid convolutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrade sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2, 3\/4, 1 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil lengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 to 500 ft by size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V nominal or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVapors, solids, and weather per the published listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFittings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eListed liquidtight nonmetallic connectors, quoted separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotor feeders, branch and control circuits, equipment whips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4 in. x 100 ft coil listed at 18.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first; coil counts confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eFactory coil in the selected trade size and length; fittings quoted separately\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTerminate with listed liquidtight nonmetallic fittings sized to the conduit; count both ends of every run.\u003c\/li\u003e\n\u003cli\u003eSupport and secure per NEC spacing for the conduit type and size.\u003c\/li\u003e\n\u003cli\u003eRespect minimum bend radius; the convolutions flex without kinking when the radius stays honest.\u003c\/li\u003e\n\u003cli\u003eConfirm conductor fill per NEC for multi-conductor pulls.\u003c\/li\u003e\n\u003cli\u003eCoil counts, cut plans, and fitting pairings are confirmed at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat fittings does it take?\u003c\/strong\u003e\u003cbr\u003eListed liquidtight nonmetallic connectors in the matching trade size: the SealPath 3\/4 in. and TightSeal 1\/2 in. series quote alongside the coils.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it rated for outdoor condenser whips?\u003c\/strong\u003e\u003cbr\u003eYes. The liquid-tight wall protects against weather per the published listing, and flexible routing absorbs equipment vibration. Assemble with listed fittings to keep the seal.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat circuits can run inside?\u003c\/strong\u003e\u003cbr\u003eCircuits of 600V nominal or less per the published listing, including motor feeders, branch circuits, and control wiring.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo you carry metallic liquidtight or preassembled whips?\u003c\/strong\u003e\u003cbr\u003eYes, as quote-on-request items: metallic liquidtight conduit, aluminum flexible conduit, and preassembled 6 ft whips all price through the desk.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-L34-FLXS-submittal.pdf?v=1783373226\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-L34-FLXS-dimensional.pdf?v=1783373226\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-L34-FLXS-install-warranty.pdf?v=1783373227\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"1\/2 in. \/ 25 ft","offer_id":48943866315008,"sku":"LA-LGT-CN-L34-FLXS-12X25","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/2 in. \/ 100 ft","offer_id":48943866347776,"sku":"LA-LGT-CN-L34-FLXS-12X100","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/2 in. \/ 500 ft","offer_id":48943866380544,"sku":"LA-LGT-CN-L34-FLXS-12X500","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/4 in. \/ 25 ft","offer_id":48943866413312,"sku":"LA-LGT-CN-L34-FLXS-34X25","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/4 in. \/ 100 ft","offer_id":48943866446080,"sku":"LA-LGT-CN-L34-FLXS-34X100","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/4 in. \/ 250 ft","offer_id":48943866478848,"sku":"LA-LGT-CN-L34-FLXS-34X250","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1 in. \/ 50 ft","offer_id":48943866511616,"sku":"LA-LGT-CN-L34-FLXS-1X50","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1 in. \/ 100 ft","offer_id":48943866544384,"sku":"LA-LGT-CN-L34-FLXS-1X100","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1 in. \/ 150 ft","offer_id":48943866577152,"sku":"LA-LGT-CN-L34-FLXS-1X150","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_57a8c723-396c-4aed-ba27-702901e88cb7.png?v=1783372947"},{"product_id":"light-archon-ironpath-rigid-metal-conduit-2-in","title":"Light Archon IronPath Rigid Metal Conduit, 2 in. x 10 ft.","description":"\u003cp\u003eLight Archon IronPath is heavy-wall rigid metal conduit for the runs that take abuse: service masts, exposed yard and dock runs, mechanical rooms, and anywhere the raceway itself is the armor. Sticks quote in the 2 in. trade size at 10 ft.\u003c\/p\u003e\u003cp\u003eThe galvanized heavy-wall steel puts the maximum standard raceway protection around feeders and branch conductors, and it serves as an equipment grounding conductor when assembled with listed fittings per NEC. Threaded joints are the standard method for the type. Where the takeoff needs elbows, couplings, nipples, or other trade sizes, the desk quotes them with the sticks at review.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHeavy-wall galvanized steel raceway for maximum physical protection\u003c\/li\u003e\n\u003cli\u003e2 in. trade size in 10 ft sticks\u003c\/li\u003e\n\u003cli\u003eServes as an equipment grounding conductor with listed fittings per NEC\u003c\/li\u003e\n\u003cli\u003eSuits service masts, exposed runs, and damage-prone routes\u003c\/li\u003e\n\u003cli\u003eInterior and exterior use installed per NEC\u003c\/li\u003e\n\u003cli\u003eElbows, couplings, and other trade sizes quoted on request\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with submittal support\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRigid metal conduit, heavy wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrade size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStick length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJoints\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThreaded, standard for the type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGround path\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEquipment grounding conductor with listed fittings per NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExposed, concealed, interior, exterior per NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeaviest standard raceway wall class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first; bundle counts and fittings quoted together\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eConduit sticks only; elbows, couplings, straps, and fittings quoted separately\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCut, thread, and ream field joints per standard rigid conduit practice; use listed fittings.\u003c\/li\u003e\n\u003cli\u003eSupport and secure per NEC spacing for the trade size.\u003c\/li\u003e\n\u003cli\u003eRaintight or wet-location fittings on exterior runs per NEC.\u003c\/li\u003e\n\u003cli\u003eBond the raceway into the equipment grounding path per NEC.\u003c\/li\u003e\n\u003cli\u003eFitting types, bend counts, and bundle quantities are confirmed at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhen does rigid beat EMT?\u003c\/strong\u003e\u003cbr\u003eWhere the raceway needs to survive impact and weather on its own: service masts, exposed low runs, loading areas, and installs the inspector calls out for physical damage protection. EMT covers lighter-duty runs at lower cost; both quote through the desk.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo you stock other rigid trade sizes?\u003c\/strong\u003e\u003cbr\u003eThe quoted stick is 2 in. x 10 ft. Other trade sizes, elbows, nipples, and couplings are quoted on request through the desk.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it serve as the ground path?\u003c\/strong\u003e\u003cbr\u003eYes. Assembled with listed fittings and installed per NEC, rigid metal conduit serves as an equipment grounding conductor.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do sticks join?\u003c\/strong\u003e\u003cbr\u003eThreaded couplings and fittings, the standard method for the type. Field threads are cut, reamed, and sealed per standard practice.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-R2-IRNP-submittal.pdf?v=1783373231\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-R2-IRNP-dimensional.pdf?v=1783373231\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-CN-R2-IRNP-install-warranty.pdf?v=1783373231\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Default Title","offer_id":48943866675456,"sku":"LA-LGT-CN-R2-IRNP","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_fe4c49de-7e4e-4d70-8be5-d670bfe24ae7.png?v=1783372949"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/collections\/conduit-and-fittings.png?v=1783313484","url":"https:\/\/ironcinder.com\/collections\/conduit-and-fittings\/accessory_connector.oembed","provider":"IronCinder","version":"1.0","type":"link"}