{"title":"Outlets and Devices","description":"\u003cp\u003eDuplex, GFCI, and USB receptacles alongside toggle and rocker switches. Tamper resistant designs for residential code compliance, packed in contractor quantities. Device counts quoted straight from your fixture and device schedule.\u003c\/p\u003e","products":[{"product_id":"light-archon-crestline-15a-duplex-outlet-10-pack","title":"Light Archon Crestline 15A Duplex Outlet 10-Pack","description":"\u003cp\u003eLight Archon Crestline duplex outlets are the rough-in staple, sold in contractor 10-packs so full floors quote in one line. Pick the classic duplex face or the designer rectangular face, standard or tamper resistant, all 15 A, 125V, NEMA 5-15R in White.\u003c\/p\u003e\u003cp\u003eTamper resistant versions carry the TR shutter mechanism the NEC requires in most dwelling locations: the shutters stay closed unless both prongs of a plug insert at the same time, locking out keys and hairpins. The shallow body leaves room for conductors in the box, and heavy-duty ultrasonic construction holds up on the job. Devices back wire and side wire with screw terminals for fast production work.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15 A, 125V duplex receptacle, NEMA 5-15R\u003c\/li\u003e\n\u003cli\u003eContractor 10-pack; one line covers a full floor of rough-in\u003c\/li\u003e\n\u003cli\u003eClassic duplex or designer rectangular face\u003c\/li\u003e\n\u003cli\u003eStandard and tamper resistant versions\u003c\/li\u003e\n\u003cli\u003eTR shutter mechanism meets NEC receptacle requirements for dwellings\u003c\/li\u003e\n\u003cli\u003eShallow body for easier box fill\u003c\/li\u003e\n\u003cli\u003eBack wire and side wire with screw terminals\u003c\/li\u003e\n\u003cli\u003eUL Listed and CSA Listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClassic duplex and designer rectangular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard and tamper resistant (TR shutters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 devices per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBack and side wire, screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included; 1-gang plates quoted separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTen devices per pack in the selected face and version\u003c\/li\u003e\n\u003cli\u003eMounting screws\u003c\/li\u003e\n\u003cli\u003eWall plates not included; 1-gang plates quoted separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician in standard single-gang boxes; verify box fill\u003c\/li\u003e\n\u003cli\u003eTamper resistant receptacles are required by the NEC in most dwelling locations\u003c\/li\u003e\n\u003cli\u003eDo not install on circuits above the device rating\u003c\/li\u003e\n\u003cli\u003eClassic faces take standard duplex plates; designer faces take designer opening plates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat box does it need?\u003c\/strong\u003e\u003cbr\u003eA standard single-gang wall box per device. Have the installer verify box fill for the conductors present.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo the two faces need different plates?\u003c\/strong\u003e\u003cbr\u003eYes. The classic duplex face takes a standard duplex wall plate; the designer rectangular face takes a designer opening plate. Plates are quoted separately.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo I need the tamper resistant version?\u003c\/strong\u003e\u003cbr\u003eThe NEC requires TR receptacles in most dwelling locations. Pick the TR variant unless your inspector confirms the location is exempt.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow are the packs quoted?\u003c\/strong\u003e\u003cbr\u003eEach variant is a 10-pack line item. Add the counts you need to your quote list and the trade desk prices the job as one release.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-D15-CREST-submittal.pdf?v=1783306847\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-D15-CREST-dimensional.pdf?v=1783306847\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-D15-CREST-install-warranty.pdf?v=1783306847\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Classic Duplex \/ Tamper Resistant","offer_id":48934492832000,"sku":"LA-LGT-DV-D15-CREST-CTR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Designer Rectangular \/ Tamper Resistant","offer_id":48934492864768,"sku":"LA-LGT-DV-D15-CREST-DTR","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Designer Rectangular \/ Standard","offer_id":48934492897536,"sku":"LA-LGT-DV-D15-CREST-DST","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Classic Duplex \/ Standard","offer_id":48934492930304,"sku":"LA-LGT-DV-D15-CREST-CST","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_efd8ac1b-1d65-4ebf-b5eb-cc5b7fab36d7.png?v=1783306419"},{"product_id":"light-archon-sentinel-15a-self-test-gfci-duplex-outlet","title":"Light Archon Sentinel 15A Self-Test GFCI Duplex Outlet","description":"\u003cp\u003eLight Archon Sentinel GFCI outlets put self-test ground fault protection in a slim body that fits shallow and crowded boxes. The platform runs four colors with standard or tamper resistant versions, all 15 A, 125V, NEMA 5-15R, so one line covers kitchens, baths, laundry areas, and every other location the code calls out.\u003c\/p\u003e\u003cp\u003eThe device tests itself within seconds of power-up and keeps checking automatically, beyond the base UL requirement, while staying able to trip on a real ground fault even mid-test. A status indicator light shows power and protection state and flags line\/load reversal. A lockout action blocks reset when the device cannot respond to a ground fault. Electronics are tuned to resist nuisance trips from high-frequency noise, and the reduced-depth body leaves room for conductors in any standard single-gang box. Back and side wire terminations with external clamps show proper wire seating at a glance.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15 A, 125V self-test GFCI duplex, NEMA 5-15R\u003c\/li\u003e\n\u003cli\u003eAutomatic self-test runs from power-up and repeats continuously\u003c\/li\u003e\n\u003cli\u003eStatus indicator light with line\/load reversal indication\u003c\/li\u003e\n\u003cli\u003eLockout action blocks reset if protection is compromised\u003c\/li\u003e\n\u003cli\u003eSlim reduced-depth body for shallow boxes\u003c\/li\u003e\n\u003cli\u003eBack and side wire capable with external clamp seating indication\u003c\/li\u003e\n\u003cli\u003eFour colors with standard and tamper resistant versions\u003c\/li\u003e\n\u003cli\u003eFeed-through protection for downstream outlets\u003c\/li\u003e\n\u003cli\u003eUL Listed and CSA Listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A GFCI with automatic self-test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatus light for power, protection state, line\/load reversal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSlim reduced depth for shallow boxes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBack and side wire, screw terminals with external clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite, Ivory, Gray, Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard and tamper resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included; standard 1-gang plates quoted separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSentinel GFCI device in the selected color and version\u003c\/li\u003e\n\u003cli\u003eMounting screws\u003c\/li\u003e\n\u003cli\u003eWall plate not included; standard 1-gang plates quoted separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician in a standard single-gang box; verify box fill\u003c\/li\u003e\n\u003cli\u003eGFCI protection locations per the NEC: kitchens, baths, laundry areas, outdoor and other wet or damp locations per the adopted edition\u003c\/li\u003e\n\u003cli\u003eLand line and load correctly; the indicator flags reversal\u003c\/li\u003e\n\u003cli\u003eFeed-through protection covers downstream outlets when landed on the load terminals\u003c\/li\u003e\n\u003cli\u003ePress TEST monthly in addition to the automatic self-test\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat box does it need?\u003c\/strong\u003e\u003cbr\u003eA standard single-gang wall box. The slim body helps in shallow boxes, but your installer should still verify box fill for the conductors present.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo I need the tamper resistant version?\u003c\/strong\u003e\u003cbr\u003eThe NEC requires tamper resistant receptacles in most dwelling locations. Pick the TR variant unless your inspector confirms the location is exempt.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does the status light show?\u003c\/strong\u003e\u003cbr\u003ePower and protection state, plus indication of line\/load reversal at install. A device that loses the ability to protect locks out and will not reset.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it protect downstream outlets?\u003c\/strong\u003e\u003cbr\u003eYes. Feed-through terminals extend GFCI protection to downstream outlets when your electrician lands them on the load side.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-SNTL-submittal.pdf?v=1783306852\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-SNTL-dimensional.pdf?v=1783306852\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-SNTL-install-warranty.pdf?v=1783306852\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"White \/ Standard","offer_id":48934492963072,"sku":"LA-LGT-DV-G15-SNTL-WH","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Ivory \/ Standard","offer_id":48934492995840,"sku":"LA-LGT-DV-G15-SNTL-IV","price":0.0,"currency_code":"USD","in_stock":true},{"title":"White \/ Tamper Resistant","offer_id":48934493028608,"sku":"LA-LGT-DV-G15-SNTL-TRWH","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Gray \/ Tamper Resistant","offer_id":48934493061376,"sku":"LA-LGT-DV-G15-SNTL-TRGY","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Black \/ Tamper Resistant","offer_id":48934493094144,"sku":"LA-LGT-DV-G15-SNTL-TRBK","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_36a3e32c-c5e6-44d2-9689-6c1426a684bf.png?v=1783306427"},{"product_id":"light-archon-hearthline-15a-duplex-outlet","title":"Light Archon Hearthline 15A Duplex Outlet","description":"\u003cp\u003eLight Archon Hearthline outlets are the everyday 15 A, 125V duplex receptacles bought by the box for production work. One platform covers the classic duplex face and the designer rectangular face, in standard or tamper resistant versions, White or Ivory. Quote-first: add the count you need and the trade desk prices the list line by line.\u003c\/p\u003e\u003cp\u003eThe body is impact-resistant polycarbonate with a shallow depth that leaves wiring room in crowded boxes. Terminations take back or side wiring on screw terminals, mounting screws are captive, and the plaster ears break off cleanly for flush alignment on finished walls. Tamper resistant versions add the shuttered contacts the NEC requires in most dwelling locations. NEMA 5-15R contact pattern, UL Listed and CSA Listed.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15 A, 125V duplex receptacle, NEMA 5-15R\u003c\/li\u003e\n\u003cli\u003eClassic duplex and designer rectangular faces on one platform\u003c\/li\u003e\n\u003cli\u003eStandard and tamper resistant versions\u003c\/li\u003e\n\u003cli\u003eWhite and Ivory colorways\u003c\/li\u003e\n\u003cli\u003eImpact-resistant polycarbonate body\u003c\/li\u003e\n\u003cli\u003eShallow design leaves wiring room in the box\u003c\/li\u003e\n\u003cli\u003eBack and side wire capable screw terminals\u003c\/li\u003e\n\u003cli\u003eCaptive mounting screws with break-off plaster ears\u003c\/li\u003e\n\u003cli\u003eUL Listed and CSA Listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClassic duplex, designer rectangular\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard and tamper resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite, Ivory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eImpact-resistant polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShallow design for maximum wiring room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBack and side wire, screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCaptive screws, break-off plaster ears\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included; duplex or designer opening plates by face, quoted separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne Hearthline duplex device in the selected face, version, and color\u003c\/li\u003e\n\u003cli\u003eMounting screws\u003c\/li\u003e\n\u003cli\u003eWall plate not included; plates quoted separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician in a standard single-gang box; verify box fill\u003c\/li\u003e\n\u003cli\u003eTamper resistant versions satisfy the NEC dwelling receptacle requirement in most locations\u003c\/li\u003e\n\u003cli\u003eClassic duplex faces take duplex plates; designer rectangular faces take designer opening plates\u003c\/li\u003e\n\u003cli\u003eBreak off the plaster ears only when the wall surface needs the strap tight to the box\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat box does it need?\u003c\/strong\u003e\u003cbr\u003eA standard single-gang wall box. Your installer verifies box fill for the conductors present per NEC 314.16.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo I need the tamper resistant version?\u003c\/strong\u003e\u003cbr\u003eThe NEC requires tamper resistant receptacles in most dwelling locations. Pick the TR variant unless your inspector confirms the location is exempt.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich wall plate fits?\u003c\/strong\u003e\u003cbr\u003eClassic duplex faces take standard duplex plates; designer rectangular faces take designer opening plates. Both are quoted separately.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with counts and colors confirmed line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-D15-HRTH-submittal_e12b9ef6-14f2-4e0e-af80-852e3ed7bafb.pdf?v=1783446622\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-D15-HRTH-dimensional_8a4d8f01-f870-44ad-9dcf-565773211fd2.pdf?v=1783446622\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-D15-HRTH-install-warranty_14eb55ed-f959-4ec8-9970-78cd3893613d.pdf?v=1783446622\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Classic Duplex \/ Standard \/ White","offer_id":48943866937600,"sku":"LA-LGT-DV-D15-HRTH-CSW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Classic Duplex \/ Standard \/ Ivory","offer_id":48943866970368,"sku":"LA-LGT-DV-D15-HRTH-CSI","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Classic Duplex \/ Tamper Resistant \/ White","offer_id":48943867003136,"sku":"LA-LGT-DV-D15-HRTH-CTW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Designer Rectangular \/ Standard \/ White","offer_id":48943867035904,"sku":"LA-LGT-DV-D15-HRTH-DSW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Designer Rectangular \/ Tamper Resistant \/ White","offer_id":48943867068672,"sku":"LA-LGT-DV-D15-HRTH-DTW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38536656847104.png?v=1783434936"},{"product_id":"light-archon-parapet-15a-self-test-gfci-outlet-4-pack","title":"Light Archon Parapet 15A Self-Test GFCI Outlet 4-Pack","description":"\u003cp\u003eThe Light Archon Parapet 4-pack puts self-test GFCI protection on the truck in contractor count: four 15 A, 125V tamper resistant duplex devices per line item, covering the kitchen, both baths, and the laundry room of a typical dwelling in one quote line. Quote-first: add it to your quote list and the trade desk confirms counts before release.\u003c\/p\u003e\u003cp\u003eEach device tests itself within seconds of power-up and keeps checking automatically beyond the base UL requirement, while staying able to trip on a real ground fault even mid-test. The status indicator light reads out power and protection state and flags line\/load reversal at install. Electronics carry improved immunity to high-frequency noise and electrical surges, cutting nuisance trips from appliances and electronics. The reduced-depth polycarbonate body works in shallow boxes, and back or side wiring with external clamps shows proper conductor seating at a glance.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4-pack of 15 A, 125V self-test GFCI duplex devices, NEMA 5-15R\u003c\/li\u003e\n\u003cli\u003eTamper resistant shuttered contacts\u003c\/li\u003e\n\u003cli\u003eAutomatic self-test runs from power-up and repeats continuously\u003c\/li\u003e\n\u003cli\u003eStatus indicator light with line\/load reversal indication\u003c\/li\u003e\n\u003cli\u003eHigh-frequency noise and surge immunity reduces nuisance trips\u003c\/li\u003e\n\u003cli\u003eReduced-depth body for shallow boxes\u003c\/li\u003e\n\u003cli\u003eBack and side wire capable with external clamp seating indication\u003c\/li\u003e\n\u003cli\u003eFeed-through protection for downstream outlets\u003c\/li\u003e\n\u003cli\u003eUL Listed and CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A GFCI with automatic self-test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTamper resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatus light for power, protection state, line\/load reversal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReduced depth for shallow boxes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBack and side wire, screw terminals with external clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included; designer opening plates quoted separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 x Parapet self-test tamper resistant GFCI devices, White\u003c\/li\u003e\n\u003cli\u003eMounting screws\u003c\/li\u003e\n\u003cli\u003eWall plates not included; designer opening plates quoted separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician in standard single-gang boxes; verify box fill\u003c\/li\u003e\n\u003cli\u003eGFCI protection locations per the NEC: kitchens, baths, laundry areas, and other locations per the adopted edition\u003c\/li\u003e\n\u003cli\u003eLand line and load correctly; the indicator flags reversal\u003c\/li\u003e\n\u003cli\u003eFeed-through protection covers downstream outlets when landed on the load terminals\u003c\/li\u003e\n\u003cli\u003ePress TEST monthly in addition to the automatic self-test\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat box does it need?\u003c\/strong\u003e\u003cbr\u003eA standard single-gang wall box. Your installer verifies box fill for the conductors present per NEC 314.16.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy buy the 4-pack?\u003c\/strong\u003e\u003cbr\u003eCount. A typical dwelling GFCI schedule runs four to six devices; the 4-pack covers it in one line item, and the trade desk scales counts up at quote review for multi-unit work.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does the status light show?\u003c\/strong\u003e\u003cbr\u003ePower and protection state, plus indication of line\/load reversal at install. A device that loses the ability to protect locks out and will not reset.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich wall plate fits?\u003c\/strong\u003e\u003cbr\u003eThe designer rectangular opening. Plates are quoted separately.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-PRPT-submittal_6180a342-e6dd-4850-ac2a-412ae40b4b49.pdf?v=1783391479\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-PRPT-dimensional_f014b6e5-72fc-4ec4-b3c0-2517104e5726.pdf?v=1783391479\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-PRPT-install-warranty_123b3695-f3cf-4b50-8acc-97b09ce01655.pdf?v=1783391480\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Default Title","offer_id":48943867298048,"sku":"LA-LGT-DV-G15-PRPT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_fe375b49-def2-4d0b-91cb-d135be45ad7c.png?v=1783391472"},{"product_id":"light-archon-quicklatch-15a-self-test-gfci-outlet-with-lever-terminals-3-pack","title":"Light Archon Quicklatch 15A Self-Test GFCI Outlet with Lever Terminals 3-Pack","description":"\u003cp\u003eLight Archon Quicklatch GFCIs replace screw-terminal wiring with tool-free lever terminals: strip, insert, and snap the lever shut. Sold as a 3-pack of 15 A, 125V self-test tamper resistant duplex devices, it is built for production GFCI work in kitchens, baths, and laundry rooms. Quote-first: add it to your quote list and the trade desk confirms counts before release.\u003c\/p\u003e\u003cp\u003eEach lever terminal closes with an audible click, holds 12 or 14 AWG solid or stranded copper, and leaves no exposed metal parts, so there is nothing to tape. The blue load lever separates line from load at a glance and cuts miswiring risk. Protection is the full self-test package: continuous auto-monitoring beyond the base UL requirement, a status indicator light with line\/load reversal indication, and a lockout action that blocks reset if the device can no longer protect. The extended strap uses tongue and groove alignment for faster multi-gang trim-out, fits midway plates as shipped, and takes standard plates once the breakaway tab is removed.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3-pack of 15 A, 125V self-test GFCI duplex devices, NEMA 5-15R\u003c\/li\u003e\n\u003cli\u003eTool-free lever-action terminals with audible click confirmation\u003c\/li\u003e\n\u003cli\u003eBlue load lever separates line from load at a glance\u003c\/li\u003e\n\u003cli\u003eNo exposed metal parts; no taping\u003c\/li\u003e\n\u003cli\u003eTamper resistant shuttered contacts\u003c\/li\u003e\n\u003cli\u003eAutomatic self-test with status indicator and lockout action\u003c\/li\u003e\n\u003cli\u003eExtended strap with tongue and groove alignment for multi-gang trim-out\u003c\/li\u003e\n\u003cli\u003eTakes 12-14 AWG solid and stranded copper\u003c\/li\u003e\n\u003cli\u003eUL Listed and CSA Certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A GFCI with automatic self-test and lockout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTamper resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTool-free lever action, color coded, blue load lever\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-14 AWG solid and stranded copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatus light for power, protection state, line\/load reversal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrap\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExtended, tongue and groove alignment; midway plates as shipped, standard plates via breakaway tab\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePack\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e3 x Quicklatch self-test tamper resistant GFCI devices, White\u003c\/li\u003e\n\u003cli\u003eMounting screws\u003c\/li\u003e\n\u003cli\u003eWall plates not included; designer opening plates quoted separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician in a standard single-gang box; verify box fill\u003c\/li\u003e\n\u003cli\u003eStrip to the gauge mark, insert the conductor, and snap the lever closed; listen for the click\u003c\/li\u003e\n\u003cli\u003eLand line and load correctly; the blue lever marks the load side and the indicator flags reversal\u003c\/li\u003e\n\u003cli\u003eGFCI protection locations per the NEC: kitchens, baths, laundry areas, and other locations per the adopted edition\u003c\/li\u003e\n\u003cli\u003eRemove the strap breakaway tab when trimming with standard size plates\u003c\/li\u003e\n\u003cli\u003ePress TEST monthly in addition to the automatic self-test\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat box does it need?\u003c\/strong\u003e\u003cbr\u003eA standard single-gang wall box. Your installer verifies box fill for the conductors present per NEC 314.16.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do the lever terminals work?\u003c\/strong\u003e\u003cbr\u003eOpen the lever, insert stripped 12 or 14 AWG copper into the wire opening, and snap the lever shut. The click confirms the connection, and the closed housing leaves no exposed metal to tape.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo they work with stranded wire?\u003c\/strong\u003e\u003cbr\u003eYes. The lever terminals take both solid and stranded copper in 12 and 14 AWG.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich wall plate fits?\u003c\/strong\u003e\u003cbr\u003eThe designer rectangular opening. The extended strap fits midway plates as shipped and standard plates after the breakaway tab is removed. Plates are quoted separately.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-QLTCH-submittal_812a7c3f-a200-46ff-9eb9-be5546ab4924.pdf?v=1783446628\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-QLTCH-dimensional_8556b05a-a66f-4387-97cc-b3a792103998.pdf?v=1783446628\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-QLTCH-install-warranty_05e8c7f6-f6fc-46a0-aca3-5cbba013eebb.pdf?v=1783446628\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Default Title","offer_id":48943867592960,"sku":"LA-LGT-DV-G15-QLTCH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38536714682624.png?v=1783434895"},{"product_id":"light-archon-tempest-15a-self-test-weather-resistant-gfci-outlet","title":"Light Archon Tempest 15A Self-Test Weather Resistant GFCI Outlet","description":"\u003cp\u003eThe Light Archon Tempest GFCI is the outdoor-duty version of the self-test ground fault receptacle: tamper resistant and weather resistant in one 15 A, 125V duplex, built for porches, patios, garages, and every damp or wet location the code sends you to. Quote-first: add it to your quote list and the trade desk confirms counts and covers before release.\u003c\/p\u003e\u003cp\u003eThe device tests itself within seconds of power-up and keeps checking automatically beyond the base UL requirement, while staying able to trip on a real ground fault even mid-test. A status indicator light reads out power and protection state and flags line\/load reversal at install. The weather resistant construction resists corrosion and UV in outdoor boxes behind a listed in-use cover, and the tamper resistant shutters satisfy the dwelling receptacle rule. Electronics are tuned against high-frequency nuisance trips, and the reduced-depth body with back and side wiring keeps shallow outdoor boxes workable.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15 A, 125V self-test GFCI duplex, NEMA 5-15R\u003c\/li\u003e\n\u003cli\u003eTamper resistant and weather resistant in one device\u003c\/li\u003e\n\u003cli\u003eAutomatic self-test runs from power-up and repeats continuously\u003c\/li\u003e\n\u003cli\u003eStatus indicator light with line\/load reversal indication\u003c\/li\u003e\n\u003cli\u003eHigh-frequency noise immunity reduces nuisance trips\u003c\/li\u003e\n\u003cli\u003eReduced-depth body for shallow boxes\u003c\/li\u003e\n\u003cli\u003eBack and side wire capable with external clamp seating indication\u003c\/li\u003e\n\u003cli\u003eFeed-through protection for downstream outlets\u003c\/li\u003e\n\u003cli\u003eUL Listed and CSA Listed\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 5-15R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A GFCI with automatic self-test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTamper resistant and weather resistant, one device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDamp and wet locations behind a listed in-use cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatus light for power, protection state, line\/load reversal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReduced depth for shallow boxes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBack and side wire, screw terminals with external clamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Plate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot included; outdoor locations need a listed weatherproof in-use cover, quoted separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, CSA Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTempest tamper resistant weather resistant GFCI device, White\u003c\/li\u003e\n\u003cli\u003eMounting screws\u003c\/li\u003e\n\u003cli\u003eWall plate and weatherproof cover not included; quoted separately\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician in a standard single-gang box; verify box fill\u003c\/li\u003e\n\u003cli\u003eOutdoor locations require a listed weatherproof in-use cover per the NEC\u003c\/li\u003e\n\u003cli\u003eGFCI protection locations per the NEC: outdoor, bath, garage, and other damp or wet locations per the adopted edition\u003c\/li\u003e\n\u003cli\u003eLand line and load correctly; the indicator flags reversal\u003c\/li\u003e\n\u003cli\u003eFeed-through protection covers downstream outlets when landed on the load terminals\u003c\/li\u003e\n\u003cli\u003ePress TEST monthly in addition to the automatic self-test\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat box does it need?\u003c\/strong\u003e\u003cbr\u003eA standard single-gang wall box. Your installer verifies box fill for the conductors present per NEC 314.16.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it go outdoors?\u003c\/strong\u003e\u003cbr\u003eYes. The weather resistant construction is made for damp and wet locations, installed behind a listed weatherproof in-use cover per the NEC. The cover is quoted separately.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does the status light show?\u003c\/strong\u003e\u003cbr\u003ePower and protection state, plus indication of line\/load reversal at install. A device that loses the ability to protect locks out and will not reset.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it protect downstream outlets?\u003c\/strong\u003e\u003cbr\u003eYes. Feed-through terminals extend GFCI protection to downstream outlets when your electrician lands them on the load side.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-TMPST-submittal_bef8ee8f-04ca-4052-a4e1-96803a91414a.pdf?v=1783446635\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-TMPST-dimensional_0b07349e-ca0e-4789-8d9d-b1b6c7a7ce0f.pdf?v=1783446635\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-DV-G15-TMPST-install-warranty_a5ab27ff-052b-4008-8685-15b44417e585.pdf?v=1783446635\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Default Title","offer_id":48943867658496,"sku":"LA-LGT-DV-G15-TMPST","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38533719523584.png?v=1783443810"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/collections\/outlets-and-devices.png?v=1783313584","url":"https:\/\/ironcinder.com\/collections\/outlets-and-devices\/application_outdoor.oembed","provider":"IronCinder","version":"1.0","type":"link"}