{"title":"Pressure Treated Lumber","description":"\u003cp\u003eGround contact rated pressure treated lumber and posts for decks, foundations, and weather exposed framing. Sticks from 2x4 to 2x12 plus 4x4, 4x6, and 6x6 posts.\u003c\/p\u003e\u003cp\u003eTreatment class and use category are stated on every platform, with fastener guidance in the installation documents.\u003c\/p\u003e","products":[{"product_id":"lumber-god-2x10-pressure-treated-lumber-ground-contact","title":"Lumber God 2x10 Pressure Treated Lumber, Ground Contact","description":"\u003cp\u003eThis platform covers the treated 2x10 in 8 ft, 10 ft, 12 ft, 16 ft lengths. One treatment class covers the whole job: ground contact stock is rated for burial, standing moisture, and hard-to-drain details as well as everything above grade. A nominal 2x10 finishes at an actual 1.5 in. x 9.25 in. at time of manufacture; treated stock ships wet and should be allowed to season before finishing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact rated per AWPA Use Category UC4A\u003c\/li\u003e\n\u003cli\u003eTreated Hem-Fir with the preservative system and retention on the stamped end tag\u003c\/li\u003e\n\u003cli\u003eNominal 2x10, actual 1.5 in. x 9.25 in. at time of manufacture\u003c\/li\u003e\n\u003cli\u003eAvailable in 8 ft, 10 ft, 12 ft, 16 ft lengths as a single quoted platform\u003c\/li\u003e\n\u003cli\u003eSuited to floor systems, stair framing, and structural headers\u003c\/li\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber\u003c\/li\u003e\n\u003cli\u003eUnit and bundle quantities quoted by count, with jobsite delivery coordinated at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHem-Fir, pressure treated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround contact, AWPA Use Category UC4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreservative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper based waterborne preservative; system and retention per stamped end tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in. x 10 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 in. x 9.25 in. at time of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ft, 10 ft, 12 ft, 16 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTreated after surfacing; ships wet, season before finishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.05 lb per linear ft (8 ft piece about 32.4 lb, treated wet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-dip galvanized or stainless steel rated for treated lumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFloor systems, stair framing, and structural headers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact treated Hem-Fir in the quoted length and count\u003c\/li\u003e\n\u003cli\u003eStamped end tag with treatment class and retention on every piece\u003c\/li\u003e\n\u003cli\u003eBundle or unit packaging per the quoted quantity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHandling and Installation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber.\u003c\/li\u003e\n\u003cli\u003eNever burn treated offcuts; dispose of scrap per local requirements and wear a dust mask when cutting.\u003c\/li\u003e\n\u003cli\u003eField-treat cut ends with a copper naphthenate end-cut preservative to maintain the protection envelope.\u003c\/li\u003e\n\u003cli\u003eTreated stock ships wet; allow seasoning before applying paint or stain and expect minor shrinkage.\u003c\/li\u003e\n\u003cli\u003eConfirm post embedment, hardware schedule, and drainage details against the plans during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGraded and stamped under published grading rules; grade claims follow the stamped agency standard\u003c\/li\u003e\n\u003cli\u003eCount shortages and transit damage are reconciled through quote review support after delivery\u003c\/li\u003e\n\u003cli\u003eFinal counts, configuration, and delivery windows are confirmed during quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does ground contact rated mean?\u003c\/strong\u003e\u003cbr\u003eThe treatment retention meets AWPA Use Category UC4A, so the piece is approved for direct soil or standing water contact, on-grade framing, and other hard service locations, as well as everything above grade.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich fasteners should I use?\u003c\/strong\u003e\u003cbr\u003eHot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber. Standard bright fasteners corrode in contact with the preservative.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I paint or stain it right away?\u003c\/strong\u003e\u003cbr\u003eNo. Treated stock ships wet. Allow it to season until water no longer beads on the surface, typically several weeks exposed, before applying finish.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the actual size of a treated 2x10?\u003c\/strong\u003e\u003cbr\u003e1.5 in. x 9.25 in. at time of manufacture. Treated lumber can vary slightly with moisture content as it seasons.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X10-submittal_7a8389fb-38b7-4d38-b281-ec2139d5f7fc.pdf?v=1783138657\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X10-dimensional_69cad420-e793-4f20-9403-2cbf9dec97f2.pdf?v=1783138657\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X10-install-warranty_b185d1ae-59a1-4e39-835e-0097ff0f65be.pdf?v=1783138657\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumber God","offers":[{"title":"8 ft","offer_id":48929138213120,"sku":"LG-LBR-PT-2X10-8FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 ft","offer_id":48929138245888,"sku":"LG-LBR-PT-2X10-10FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":48929138278656,"sku":"LG-LBR-PT-2X10-12FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"16 ft","offer_id":48929138311424,"sku":"LG-LBR-PT-2X10-16FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_4691f78e-0f36-49e3-8a0d-8f1746a00965.png?v=1783138591"},{"product_id":"lumber-god-2x12-pressure-treated-lumber-ground-contact","title":"Lumber God 2x12 Pressure Treated Lumber, Ground Contact","description":"\u003cp\u003eThis platform covers the treated 2x12 in 8 ft, 10 ft, 12 ft, 16 ft lengths. Ground contact rating means the same stick is approved for the hardest service in the table: in ground, on concrete, poor drainage, or splash zones, so crews do not have to segregate above ground and burial stock. A nominal 2x12 finishes at an actual 1.5 in. x 11.25 in. at time of manufacture; treated stock ships wet and should be allowed to season before finishing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact rated per AWPA Use Category UC4A\u003c\/li\u003e\n\u003cli\u003eTreated Hem-Fir with the preservative system and retention on the stamped end tag\u003c\/li\u003e\n\u003cli\u003eNominal 2x12, actual 1.5 in. x 11.25 in. at time of manufacture\u003c\/li\u003e\n\u003cli\u003eAvailable in 8 ft, 10 ft, 12 ft, 16 ft lengths as a single quoted platform\u003c\/li\u003e\n\u003cli\u003eSuited to long span joists, stair stringers, and built-up beams\u003c\/li\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber\u003c\/li\u003e\n\u003cli\u003eUnit and bundle quantities quoted by count, with jobsite delivery coordinated at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHem-Fir, pressure treated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround contact, AWPA Use Category UC4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreservative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper based waterborne preservative; system and retention per stamped end tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in. x 12 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 in. x 11.25 in. at time of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ft, 10 ft, 12 ft, 16 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTreated after surfacing; ships wet, season before finishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.92 lb per linear ft (8 ft piece about 39.4 lb, treated wet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-dip galvanized or stainless steel rated for treated lumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLong span joists, stair stringers, and built-up beams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact treated Hem-Fir in the quoted length and count\u003c\/li\u003e\n\u003cli\u003eStamped end tag with treatment class and retention on every piece\u003c\/li\u003e\n\u003cli\u003eBundle or unit packaging per the quoted quantity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHandling and Installation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber.\u003c\/li\u003e\n\u003cli\u003eNever burn treated offcuts; dispose of scrap per local requirements and wear a dust mask when cutting.\u003c\/li\u003e\n\u003cli\u003eField-treat cut ends with a copper naphthenate end-cut preservative to maintain the protection envelope.\u003c\/li\u003e\n\u003cli\u003eTreated stock ships wet; allow seasoning before applying paint or stain and expect minor shrinkage.\u003c\/li\u003e\n\u003cli\u003eConfirm post embedment, hardware schedule, and drainage details against the plans during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGraded and stamped under published grading rules; grade claims follow the stamped agency standard\u003c\/li\u003e\n\u003cli\u003eCount shortages and transit damage are reconciled through quote review support after delivery\u003c\/li\u003e\n\u003cli\u003eFinal counts, configuration, and delivery windows are confirmed during quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does ground contact rated mean?\u003c\/strong\u003e\u003cbr\u003eThe treatment retention meets AWPA Use Category UC4A, so the piece is approved for direct soil or standing water contact, on-grade framing, and other hard service locations, as well as everything above grade.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich fasteners should I use?\u003c\/strong\u003e\u003cbr\u003eHot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber. Standard bright fasteners corrode in contact with the preservative.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I paint or stain it right away?\u003c\/strong\u003e\u003cbr\u003eNo. Treated stock ships wet. Allow it to season until water no longer beads on the surface, typically several weeks exposed, before applying finish.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the actual size of a treated 2x12?\u003c\/strong\u003e\u003cbr\u003e1.5 in. x 11.25 in. at time of manufacture. Treated lumber can vary slightly with moisture content as it seasons.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X12-submittal_52aeaef5-5b46-43a8-9d9f-35a810665462.pdf?v=1783138664\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X12-dimensional_a62a851c-4236-419e-a260-9b7b1035955a.pdf?v=1783138664\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X12-install-warranty_360c7e41-d0ec-4ada-b108-2873ac1dc852.pdf?v=1783138664\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumber God","offers":[{"title":"8 ft","offer_id":48929138540800,"sku":"LG-LBR-PT-2X12-8FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 ft","offer_id":48929138573568,"sku":"LG-LBR-PT-2X12-10FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":48929138606336,"sku":"LG-LBR-PT-2X12-12FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"16 ft","offer_id":48929138639104,"sku":"LG-LBR-PT-2X12-16FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_d7540b6c-2186-45d4-bcee-f5cae2eeb050.png?v=1783138597"},{"product_id":"lumber-god-2x4-pressure-treated-lumber-ground-contact","title":"Lumber God 2x4 Pressure Treated Lumber, Ground Contact","description":"\u003cp\u003eThis platform covers the treated 2x4 in 8 ft, 10 ft, 12 ft, 16 ft lengths. One treatment class covers the whole job: ground contact stock is rated for burial, standing moisture, and hard-to-drain details as well as everything above grade. A nominal 2x4 finishes at an actual 1.5 in. x 3.5 in. at time of manufacture; treated stock ships wet and should be allowed to season before finishing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact rated per AWPA Use Category UC4A\u003c\/li\u003e\n\u003cli\u003eTreated Hem-Fir with the preservative system and retention on the stamped end tag\u003c\/li\u003e\n\u003cli\u003eNominal 2x4, actual 1.5 in. x 3.5 in. at time of manufacture\u003c\/li\u003e\n\u003cli\u003eAvailable in 8 ft, 10 ft, 12 ft, 16 ft lengths as a single quoted platform\u003c\/li\u003e\n\u003cli\u003eSuited to wall framing, top and bottom plates, blocking, and general construction\u003c\/li\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber\u003c\/li\u003e\n\u003cli\u003eUnit and bundle quantities quoted by count, with jobsite delivery coordinated at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHem-Fir, pressure treated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround contact, AWPA Use Category UC4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreservative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper based waterborne preservative; system and retention per stamped end tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in. x 4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 in. x 3.5 in. at time of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ft, 10 ft, 12 ft, 16 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTreated after surfacing; ships wet, season before finishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.53 lb per linear ft (8 ft piece about 12.2 lb, treated wet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-dip galvanized or stainless steel rated for treated lumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall framing, top and bottom plates, blocking, and general construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact treated Hem-Fir in the quoted length and count\u003c\/li\u003e\n\u003cli\u003eStamped end tag with treatment class and retention on every piece\u003c\/li\u003e\n\u003cli\u003eBundle or unit packaging per the quoted quantity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHandling and Installation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber.\u003c\/li\u003e\n\u003cli\u003eNever burn treated offcuts; dispose of scrap per local requirements and wear a dust mask when cutting.\u003c\/li\u003e\n\u003cli\u003eField-treat cut ends with a copper naphthenate end-cut preservative to maintain the protection envelope.\u003c\/li\u003e\n\u003cli\u003eTreated stock ships wet; allow seasoning before applying paint or stain and expect minor shrinkage.\u003c\/li\u003e\n\u003cli\u003eConfirm post embedment, hardware schedule, and drainage details against the plans during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGraded and stamped under published grading rules; grade claims follow the stamped agency standard\u003c\/li\u003e\n\u003cli\u003eCount shortages and transit damage are reconciled through quote review support after delivery\u003c\/li\u003e\n\u003cli\u003eFinal counts, configuration, and delivery windows are confirmed during quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does ground contact rated mean?\u003c\/strong\u003e\u003cbr\u003eThe treatment retention meets AWPA Use Category UC4A, so the piece is approved for direct soil or standing water contact, on-grade framing, and other hard service locations, as well as everything above grade.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich fasteners should I use?\u003c\/strong\u003e\u003cbr\u003eHot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber. Standard bright fasteners corrode in contact with the preservative.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I paint or stain it right away?\u003c\/strong\u003e\u003cbr\u003eNo. Treated stock ships wet. Allow it to season until water no longer beads on the surface, typically several weeks exposed, before applying finish.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the actual size of a treated 2x4?\u003c\/strong\u003e\u003cbr\u003e1.5 in. x 3.5 in. at time of manufacture. Treated lumber can vary slightly with moisture content as it seasons.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X4-submittal_25380932-0e23-4da8-8bfa-d7e4cb1a7709.pdf?v=1783138670\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X4-dimensional_ab2333e4-7f83-4d9a-aad2-f0b580cb20ac.pdf?v=1783138670\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X4-install-warranty_acfbe71c-04bc-4b6e-af27-830c853d1f3c.pdf?v=1783138670\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumber God","offers":[{"title":"8 ft","offer_id":48929138901248,"sku":"LG-LBR-PT-2X4-8FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 ft","offer_id":48929138934016,"sku":"LG-LBR-PT-2X4-10FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":48929138966784,"sku":"LG-LBR-PT-2X4-12FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"16 ft","offer_id":48929138999552,"sku":"LG-LBR-PT-2X4-16FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_f3aabe0d-51e5-4948-8037-10d4b5d80766.png?v=1783138603"},{"product_id":"lumber-god-2x6-pressure-treated-lumber-ground-contact","title":"Lumber God 2x6 Pressure Treated Lumber, Ground Contact","description":"\u003cp\u003eThis platform covers the treated 2x6 in 8 ft, 10 ft, 12 ft, 16 ft lengths. Ground contact rating means the same stick is approved for the hardest service in the table: in ground, on concrete, poor drainage, or splash zones, so crews do not have to segregate above ground and burial stock. A nominal 2x6 finishes at an actual 1.5 in. x 5.5 in. at time of manufacture; treated stock ships wet and should be allowed to season before finishing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact rated per AWPA Use Category UC4A\u003c\/li\u003e\n\u003cli\u003eTreated Hem-Fir with the preservative system and retention on the stamped end tag\u003c\/li\u003e\n\u003cli\u003eNominal 2x6, actual 1.5 in. x 5.5 in. at time of manufacture\u003c\/li\u003e\n\u003cli\u003eAvailable in 8 ft, 10 ft, 12 ft, 16 ft lengths as a single quoted platform\u003c\/li\u003e\n\u003cli\u003eSuited to tall wall framing, deck framing, and roof assemblies that need extra section depth\u003c\/li\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber\u003c\/li\u003e\n\u003cli\u003eUnit and bundle quantities quoted by count, with jobsite delivery coordinated at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHem-Fir, pressure treated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround contact, AWPA Use Category UC4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreservative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper based waterborne preservative; system and retention per stamped end tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in. x 6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 in. x 5.5 in. at time of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ft, 10 ft, 12 ft, 16 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTreated after surfacing; ships wet, season before finishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.41 lb per linear ft (8 ft piece about 19.2 lb, treated wet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-dip galvanized or stainless steel rated for treated lumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTall wall framing, deck framing, and roof assemblies that need extra section depth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact treated Hem-Fir in the quoted length and count\u003c\/li\u003e\n\u003cli\u003eStamped end tag with treatment class and retention on every piece\u003c\/li\u003e\n\u003cli\u003eBundle or unit packaging per the quoted quantity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHandling and Installation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber.\u003c\/li\u003e\n\u003cli\u003eNever burn treated offcuts; dispose of scrap per local requirements and wear a dust mask when cutting.\u003c\/li\u003e\n\u003cli\u003eField-treat cut ends with a copper naphthenate end-cut preservative to maintain the protection envelope.\u003c\/li\u003e\n\u003cli\u003eTreated stock ships wet; allow seasoning before applying paint or stain and expect minor shrinkage.\u003c\/li\u003e\n\u003cli\u003eConfirm post embedment, hardware schedule, and drainage details against the plans during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGraded and stamped under published grading rules; grade claims follow the stamped agency standard\u003c\/li\u003e\n\u003cli\u003eCount shortages and transit damage are reconciled through quote review support after delivery\u003c\/li\u003e\n\u003cli\u003eFinal counts, configuration, and delivery windows are confirmed during quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does ground contact rated mean?\u003c\/strong\u003e\u003cbr\u003eThe treatment retention meets AWPA Use Category UC4A, so the piece is approved for direct soil or standing water contact, on-grade framing, and other hard service locations, as well as everything above grade.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich fasteners should I use?\u003c\/strong\u003e\u003cbr\u003eHot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber. Standard bright fasteners corrode in contact with the preservative.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I paint or stain it right away?\u003c\/strong\u003e\u003cbr\u003eNo. Treated stock ships wet. Allow it to season until water no longer beads on the surface, typically several weeks exposed, before applying finish.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the actual size of a treated 2x6?\u003c\/strong\u003e\u003cbr\u003e1.5 in. x 5.5 in. at time of manufacture. Treated lumber can vary slightly with moisture content as it seasons.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X6-submittal_67af8934-b642-46d1-9d1f-11b472b3b2e9.pdf?v=1783138677\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X6-dimensional_935efa98-bcfc-4a68-afdb-90d9fcfa4c5e.pdf?v=1783138677\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X6-install-warranty_eb6c513a-ceb0-4e34-a845-a0d292c31149.pdf?v=1783138677\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumber God","offers":[{"title":"8 ft","offer_id":48929139196160,"sku":"LG-LBR-PT-2X6-8FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 ft","offer_id":48929139228928,"sku":"LG-LBR-PT-2X6-10FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":48929139261696,"sku":"LG-LBR-PT-2X6-12FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"16 ft","offer_id":48929139294464,"sku":"LG-LBR-PT-2X6-16FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_7fdce0e3-f3bb-4063-9a1a-12749e578bbf.png?v=1783138611"},{"product_id":"lumber-god-2x8-pressure-treated-lumber-ground-contact","title":"Lumber God 2x8 Pressure Treated Lumber, Ground Contact","description":"\u003cp\u003eThis platform covers the treated 2x8 in 8 ft, 10 ft, 12 ft, 16 ft lengths. Because the platform is ground contact rated, it covers posts in soil, ledgers near grade, and framing over concrete without a second treatment class on the truck. A nominal 2x8 finishes at an actual 1.5 in. x 7.25 in. at time of manufacture; treated stock ships wet and should be allowed to season before finishing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact rated per AWPA Use Category UC4A\u003c\/li\u003e\n\u003cli\u003eTreated Hem-Fir with the preservative system and retention on the stamped end tag\u003c\/li\u003e\n\u003cli\u003eNominal 2x8, actual 1.5 in. x 7.25 in. at time of manufacture\u003c\/li\u003e\n\u003cli\u003eAvailable in 8 ft, 10 ft, 12 ft, 16 ft lengths as a single quoted platform\u003c\/li\u003e\n\u003cli\u003eSuited to floor joists, headers, and deck frames at moderate spans\u003c\/li\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber\u003c\/li\u003e\n\u003cli\u003eUnit and bundle quantities quoted by count, with jobsite delivery coordinated at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHem-Fir, pressure treated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround contact, AWPA Use Category UC4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreservative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper based waterborne preservative; system and retention per stamped end tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 in. x 8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 in. x 7.25 in. at time of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ft, 10 ft, 12 ft, 16 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTreated after surfacing; ships wet, season before finishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.17 lb per linear ft (8 ft piece about 25.4 lb, treated wet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-dip galvanized or stainless steel rated for treated lumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFloor joists, headers, and deck frames at moderate spans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact treated Hem-Fir in the quoted length and count\u003c\/li\u003e\n\u003cli\u003eStamped end tag with treatment class and retention on every piece\u003c\/li\u003e\n\u003cli\u003eBundle or unit packaging per the quoted quantity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHandling and Installation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber.\u003c\/li\u003e\n\u003cli\u003eNever burn treated offcuts; dispose of scrap per local requirements and wear a dust mask when cutting.\u003c\/li\u003e\n\u003cli\u003eField-treat cut ends with a copper naphthenate end-cut preservative to maintain the protection envelope.\u003c\/li\u003e\n\u003cli\u003eTreated stock ships wet; allow seasoning before applying paint or stain and expect minor shrinkage.\u003c\/li\u003e\n\u003cli\u003eConfirm post embedment, hardware schedule, and drainage details against the plans during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGraded and stamped under published grading rules; grade claims follow the stamped agency standard\u003c\/li\u003e\n\u003cli\u003eCount shortages and transit damage are reconciled through quote review support after delivery\u003c\/li\u003e\n\u003cli\u003eFinal counts, configuration, and delivery windows are confirmed during quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does ground contact rated mean?\u003c\/strong\u003e\u003cbr\u003eThe treatment retention meets AWPA Use Category UC4A, so the piece is approved for direct soil or standing water contact, on-grade framing, and other hard service locations, as well as everything above grade.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich fasteners should I use?\u003c\/strong\u003e\u003cbr\u003eHot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber. Standard bright fasteners corrode in contact with the preservative.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I paint or stain it right away?\u003c\/strong\u003e\u003cbr\u003eNo. Treated stock ships wet. Allow it to season until water no longer beads on the surface, typically several weeks exposed, before applying finish.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the actual size of a treated 2x8?\u003c\/strong\u003e\u003cbr\u003e1.5 in. x 7.25 in. at time of manufacture. Treated lumber can vary slightly with moisture content as it seasons.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X8-submittal_1c50dba8-27cf-46af-b060-dd3639a85c21.pdf?v=1783138683\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X8-dimensional_096e078d-ad60-4b4b-ba99-4a1265bf3e67.pdf?v=1783138683\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-2X8-install-warranty_ea533a3d-a259-4f73-9959-92ad8187e348.pdf?v=1783138684\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumber God","offers":[{"title":"8 ft","offer_id":48929139523840,"sku":"LG-LBR-PT-2X8-8FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 ft","offer_id":48929139556608,"sku":"LG-LBR-PT-2X8-10FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":48929139589376,"sku":"LG-LBR-PT-2X8-12FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"16 ft","offer_id":48929139622144,"sku":"LG-LBR-PT-2X8-16FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_fe572462-c6b7-4217-a5a9-dcc92d5cd7a1.png?v=1783138618"},{"product_id":"lumber-god-4x4-pressure-treated-post-ground-contact","title":"Lumber God 4x4 Pressure Treated Post, Ground Contact","description":"\u003cp\u003eThis platform covers the treated 4x4 in 8 ft, 10 ft, 12 ft lengths. Because the platform is ground contact rated, it covers posts in soil, ledgers near grade, and framing over concrete without a second treatment class on the truck. A nominal 4x4 finishes at an actual 3.5 in. x 3.5 in. at time of manufacture; treated stock ships wet and should be allowed to season before finishing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact rated per AWPA Use Category UC4A\u003c\/li\u003e\n\u003cli\u003eTreated Hem-Fir with the preservative system and retention on the stamped end tag\u003c\/li\u003e\n\u003cli\u003eNominal 4x4, actual 3.5 in. x 3.5 in. at time of manufacture\u003c\/li\u003e\n\u003cli\u003eAvailable in 8 ft, 10 ft, 12 ft lengths as a single quoted platform\u003c\/li\u003e\n\u003cli\u003eSuited to fence posts, deck posts, railing posts, and light structural columns\u003c\/li\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber\u003c\/li\u003e\n\u003cli\u003eUnit and bundle quantities quoted by count, with jobsite delivery coordinated at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHem-Fir, pressure treated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround contact, AWPA Use Category UC4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreservative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper based waterborne preservative; system and retention per stamped end tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 in. x 4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 in. x 3.5 in. at time of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ft, 10 ft, 12 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTreated after surfacing; ships wet, season before finishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.57 lb per linear ft (8 ft piece about 28.6 lb, treated wet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-dip galvanized or stainless steel rated for treated lumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFence posts, deck posts, railing posts, and light structural columns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact treated Hem-Fir in the quoted length and count\u003c\/li\u003e\n\u003cli\u003eStamped end tag with treatment class and retention on every piece\u003c\/li\u003e\n\u003cli\u003eBundle or unit packaging per the quoted quantity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHandling and Installation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber.\u003c\/li\u003e\n\u003cli\u003eNever burn treated offcuts; dispose of scrap per local requirements and wear a dust mask when cutting.\u003c\/li\u003e\n\u003cli\u003eField-treat cut ends with a copper naphthenate end-cut preservative to maintain the protection envelope.\u003c\/li\u003e\n\u003cli\u003eTreated stock ships wet; allow seasoning before applying paint or stain and expect minor shrinkage.\u003c\/li\u003e\n\u003cli\u003eConfirm post embedment, hardware schedule, and drainage details against the plans during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGraded and stamped under published grading rules; grade claims follow the stamped agency standard\u003c\/li\u003e\n\u003cli\u003eCount shortages and transit damage are reconciled through quote review support after delivery\u003c\/li\u003e\n\u003cli\u003eFinal counts, configuration, and delivery windows are confirmed during quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does ground contact rated mean?\u003c\/strong\u003e\u003cbr\u003eThe treatment retention meets AWPA Use Category UC4A, so the piece is approved for direct soil or standing water contact, on-grade framing, and other hard service locations, as well as everything above grade.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich fasteners should I use?\u003c\/strong\u003e\u003cbr\u003eHot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber. Standard bright fasteners corrode in contact with the preservative.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I paint or stain it right away?\u003c\/strong\u003e\u003cbr\u003eNo. Treated stock ships wet. Allow it to season until water no longer beads on the surface, typically several weeks exposed, before applying finish.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the actual size of a treated 4x4?\u003c\/strong\u003e\u003cbr\u003e3.5 in. x 3.5 in. at time of manufacture. Treated lumber can vary slightly with moisture content as it seasons.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-4X4-submittal_dc945a63-7981-45f6-8375-337ddc200c9a.pdf?v=1783138690\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-4X4-dimensional_f30ae5f5-658a-45c4-8038-d59b08435c2f.pdf?v=1783138690\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-4X4-install-warranty_36eb3676-d4d1-48af-a98d-c44d6fb0f4b6.pdf?v=1783138690\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumber God","offers":[{"title":"8 ft","offer_id":48929139851520,"sku":"LG-LBR-PT-4X4-8FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 ft","offer_id":48929139884288,"sku":"LG-LBR-PT-4X4-10FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":48929139917056,"sku":"LG-LBR-PT-4X4-12FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_a3dc069d-5ecc-4955-8827-d1de3ba607cf.png?v=1783138625"},{"product_id":"lumber-god-4x6-pressure-treated-post-ground-contact","title":"Lumber God 4x6 Pressure Treated Post, Ground Contact","description":"\u003cp\u003eThis platform covers the treated 4x6 in 8 ft, 10 ft, 12 ft lengths. One treatment class covers the whole job: ground contact stock is rated for burial, standing moisture, and hard-to-drain details as well as everything above grade. A nominal 4x6 finishes at an actual 3.5 in. x 5.5 in. at time of manufacture; treated stock ships wet and should be allowed to season before finishing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact rated per AWPA Use Category UC4A\u003c\/li\u003e\n\u003cli\u003eTreated Hem-Fir with the preservative system and retention on the stamped end tag\u003c\/li\u003e\n\u003cli\u003eNominal 4x6, actual 3.5 in. x 5.5 in. at time of manufacture\u003c\/li\u003e\n\u003cli\u003eAvailable in 8 ft, 10 ft, 12 ft lengths as a single quoted platform\u003c\/li\u003e\n\u003cli\u003eSuited to beams, carport and porch posts, and deck structure\u003c\/li\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber\u003c\/li\u003e\n\u003cli\u003eUnit and bundle quantities quoted by count, with jobsite delivery coordinated at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHem-Fir, pressure treated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround contact, AWPA Use Category UC4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreservative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper based waterborne preservative; system and retention per stamped end tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 in. x 6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 in. x 5.5 in. at time of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ft, 10 ft, 12 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTreated after surfacing; ships wet, season before finishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.61 lb per linear ft (8 ft piece about 44.9 lb, treated wet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-dip galvanized or stainless steel rated for treated lumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBeams, carport and porch posts, and deck structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact treated Hem-Fir in the quoted length and count\u003c\/li\u003e\n\u003cli\u003eStamped end tag with treatment class and retention on every piece\u003c\/li\u003e\n\u003cli\u003eBundle or unit packaging per the quoted quantity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHandling and Installation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber.\u003c\/li\u003e\n\u003cli\u003eNever burn treated offcuts; dispose of scrap per local requirements and wear a dust mask when cutting.\u003c\/li\u003e\n\u003cli\u003eField-treat cut ends with a copper naphthenate end-cut preservative to maintain the protection envelope.\u003c\/li\u003e\n\u003cli\u003eTreated stock ships wet; allow seasoning before applying paint or stain and expect minor shrinkage.\u003c\/li\u003e\n\u003cli\u003eConfirm post embedment, hardware schedule, and drainage details against the plans during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGraded and stamped under published grading rules; grade claims follow the stamped agency standard\u003c\/li\u003e\n\u003cli\u003eCount shortages and transit damage are reconciled through quote review support after delivery\u003c\/li\u003e\n\u003cli\u003eFinal counts, configuration, and delivery windows are confirmed during quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does ground contact rated mean?\u003c\/strong\u003e\u003cbr\u003eThe treatment retention meets AWPA Use Category UC4A, so the piece is approved for direct soil or standing water contact, on-grade framing, and other hard service locations, as well as everything above grade.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich fasteners should I use?\u003c\/strong\u003e\u003cbr\u003eHot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber. Standard bright fasteners corrode in contact with the preservative.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I paint or stain it right away?\u003c\/strong\u003e\u003cbr\u003eNo. Treated stock ships wet. Allow it to season until water no longer beads on the surface, typically several weeks exposed, before applying finish.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the actual size of a treated 4x6?\u003c\/strong\u003e\u003cbr\u003e3.5 in. x 5.5 in. at time of manufacture. Treated lumber can vary slightly with moisture content as it seasons.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-4X6-submittal_6d958d47-a067-48cf-9037-219ad9922f44.pdf?v=1783138697\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-4X6-dimensional_f1736968-5eff-4e47-9d33-084e8735c3e4.pdf?v=1783138697\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-4X6-install-warranty_bf792475-e1de-47d0-a8db-84d5504e45ff.pdf?v=1783138697\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumber God","offers":[{"title":"8 ft","offer_id":48929140179200,"sku":"LG-LBR-PT-4X6-8FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 ft","offer_id":48929140211968,"sku":"LG-LBR-PT-4X6-10FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":48929140244736,"sku":"LG-LBR-PT-4X6-12FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_4d1c37ae-7a35-4d58-b3ba-ced1708ca205.png?v=1783138631"},{"product_id":"lumber-god-6x6-pressure-treated-post-ground-contact","title":"Lumber God 6x6 Pressure Treated Post, Ground Contact","description":"\u003cp\u003eThis platform covers the treated 6x6 in 8 ft, 10 ft, 12 ft lengths. Ground contact rating means the same stick is approved for the hardest service in the table: in ground, on concrete, poor drainage, or splash zones, so crews do not have to segregate above ground and burial stock. A nominal 6x6 finishes at an actual 5.5 in. x 5.5 in. at time of manufacture; treated stock ships wet and should be allowed to season before finishing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact rated per AWPA Use Category UC4A\u003c\/li\u003e\n\u003cli\u003eTreated Hem-Fir with the preservative system and retention on the stamped end tag\u003c\/li\u003e\n\u003cli\u003eNominal 6x6, actual 5.5 in. x 5.5 in. at time of manufacture\u003c\/li\u003e\n\u003cli\u003eAvailable in 8 ft, 10 ft, 12 ft lengths as a single quoted platform\u003c\/li\u003e\n\u003cli\u003eSuited to structural posts, shade structure columns, and heavy outdoor structure\u003c\/li\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber\u003c\/li\u003e\n\u003cli\u003eUnit and bundle quantities quoted by count, with jobsite delivery coordinated at quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHem-Fir, pressure treated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround contact, AWPA Use Category UC4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreservative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper based waterborne preservative; system and retention per stamped end tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 in. x 6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.5 in. x 5.5 in. at time of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ft, 10 ft, 12 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTreated after surfacing; ships wet, season before finishing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.82 lb per linear ft (8 ft piece about 70.6 lb, treated wet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-dip galvanized or stainless steel rated for treated lumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical applications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStructural posts, shade structure columns, and heavy outdoor structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact treated Hem-Fir in the quoted length and count\u003c\/li\u003e\n\u003cli\u003eStamped end tag with treatment class and retention on every piece\u003c\/li\u003e\n\u003cli\u003eBundle or unit packaging per the quoted quantity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHandling and Installation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber.\u003c\/li\u003e\n\u003cli\u003eNever burn treated offcuts; dispose of scrap per local requirements and wear a dust mask when cutting.\u003c\/li\u003e\n\u003cli\u003eField-treat cut ends with a copper naphthenate end-cut preservative to maintain the protection envelope.\u003c\/li\u003e\n\u003cli\u003eTreated stock ships wet; allow seasoning before applying paint or stain and expect minor shrinkage.\u003c\/li\u003e\n\u003cli\u003eConfirm post embedment, hardware schedule, and drainage details against the plans during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGraded and stamped under published grading rules; grade claims follow the stamped agency standard\u003c\/li\u003e\n\u003cli\u003eCount shortages and transit damage are reconciled through quote review support after delivery\u003c\/li\u003e\n\u003cli\u003eFinal counts, configuration, and delivery windows are confirmed during quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does ground contact rated mean?\u003c\/strong\u003e\u003cbr\u003eThe treatment retention meets AWPA Use Category UC4A, so the piece is approved for direct soil or standing water contact, on-grade framing, and other hard service locations, as well as everything above grade.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich fasteners should I use?\u003c\/strong\u003e\u003cbr\u003eHot-dip galvanized or stainless steel fasteners and connectors rated for treated lumber. Standard bright fasteners corrode in contact with the preservative.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I paint or stain it right away?\u003c\/strong\u003e\u003cbr\u003eNo. Treated stock ships wet. Allow it to season until water no longer beads on the surface, typically several weeks exposed, before applying finish.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the actual size of a treated 6x6?\u003c\/strong\u003e\u003cbr\u003e5.5 in. x 5.5 in. at time of manufacture. Treated lumber can vary slightly with moisture content as it seasons.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-6X6-submittal_d52643bf-3204-4c20-91bf-6fad414db1b7.pdf?v=1783138705\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-6X6-dimensional_69f9961a-e36b-4b25-8468-0a4e804b2980.pdf?v=1783138704\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-6X6-install-warranty_f2f98f8f-2fdd-4681-b2c6-8a0bd5a3325e.pdf?v=1783138704\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumber God","offers":[{"title":"8 ft","offer_id":48929140474112,"sku":"LG-LBR-PT-6X6-8FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 ft","offer_id":48929140506880,"sku":"LG-LBR-PT-6X6-10FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":48929140539648,"sku":"LG-LBR-PT-6X6-12FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_e2052086-abc0-4dc7-b24e-53b3edafa37a.png?v=1783138638"},{"product_id":"lumber-god-5-4-x-6-pressure-treated-deck-board-ground-contact","title":"Lumber God 5\/4 x 6 Pressure Treated Deck Board, Ground Contact","description":"\u003cp\u003eA nominal 5\/4 x 6 deck board finishes at an actual 1 in. x 5.5 in. with rounded radius edges that shed water and stay comfortable underfoot. Ground contact treatment covers stair stringers near grade, dock service, and any surface where debris and moisture accumulate, so one board class serves the whole deck. Stocked in 8, 10, 12, and 16 ft lengths; treated stock ships wet and seasons in service.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRadius edge decking profile, nominal 5\/4 x 6, actual 1 in. x 5.5 in.\u003c\/li\u003e\n\u003cli\u003eGround contact rated per AWPA Use Category UC4A\u003c\/li\u003e\n\u003cli\u003eTreated Hem-Fir with the retention on the stamped end tag\u003c\/li\u003e\n\u003cli\u003eStocked in 8, 10, 12, and 16 ft lengths\u003c\/li\u003e\n\u003cli\u003eUse hot-dip galvanized or stainless steel deck fasteners\u003c\/li\u003e\n\u003cli\u003eQuoted by count for full deck surfaces with take-off support at review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure treated radius edge decking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecies group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHem-Fir, pressure treated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTreatment class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGround contact, AWPA Use Category UC4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePreservative\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper based waterborne; system and retention per stamped end tag\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/4 in. x 6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 in. x 5.5 in. at time of manufacture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfile\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRadius edge, four eased corners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 ft, 10 ft, 12 ft, 16 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMoisture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTreated after surfacing; ships wet, seasons in service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.60 lb per linear ft (8 ft board about 12.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFasteners\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-dip galvanized or stainless steel rated for treated lumber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eWhat Is Included\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGround contact treated deck boards in the quoted length and count\u003c\/li\u003e\n\u003cli\u003eStamped end tag with treatment class on every board\u003c\/li\u003e\n\u003cli\u003eBundle packaging per the quoted quantity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eHandling and Installation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGap boards per the installation document; wet-treated stock shrinks as it seasons.\u003c\/li\u003e\n\u003cli\u003eFasten with two hot-dip galvanized or stainless deck screws per joist crossing.\u003c\/li\u003e\n\u003cli\u003eBark side placement and pre-drilling at board ends reduce cupping and splitting.\u003c\/li\u003e\n\u003cli\u003eField-treat cut ends with a copper naphthenate end-cut preservative.\u003c\/li\u003e\n\u003cli\u003eNever burn treated offcuts; wear a dust mask when cutting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTreatment claims follow the stamped end tag and published documents\u003c\/li\u003e\n\u003cli\u003eCount shortages and transit damage reconciled through quote review support\u003c\/li\u003e\n\u003cli\u003eFinal board counts and delivery windows are confirmed during quote review\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the actual size of a 5\/4 x 6 deck board?\u003c\/strong\u003e\u003cbr\u003e1 in. thick by 5.5 in. wide at time of manufacture, with radius edges. Treated boards can vary slightly with moisture as they season.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy ground contact for a deck surface?\u003c\/strong\u003e\u003cbr\u003eDeck boards collect debris and stay wet at fastener lines and board gaps. Ground contact retention covers that service plus stairs and framing near grade, so one class serves the whole deck.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhen can I stain it?\u003c\/strong\u003e\u003cbr\u003eAfter the board seasons, when water no longer beads on the surface, typically several weeks exposed. Follow the finish maker's instructions for treated lumber.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is it sold?\u003c\/strong\u003e\u003cbr\u003eBy the board in the length you select, quoted by count against the deck take-off.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-DECK-546-submittal.pdf?v=1783191988\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-DECK-546-dimensional.pdf?v=1783191988\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LG-LBR-PT-DECK-546-install-warranty.pdf?v=1783191988\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Lumber God","offers":[{"title":"8 ft","offer_id":48931376070912,"sku":"LG-LBR-PT-DECK-546-8FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10 ft","offer_id":48931376103680,"sku":"LG-LBR-PT-DECK-546-10FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"12 ft","offer_id":48931376136448,"sku":"LG-LBR-PT-DECK-546-12FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"16 ft","offer_id":48931376169216,"sku":"LG-LBR-PT-DECK-546-16FT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_1ec5762e-9eaa-4cb0-ad79-4eddcfed1e8e.png?v=1783191948"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/collections\/pressure-treated-lumber.png?v=1783133866","url":"https:\/\/ironcinder.com\/collections\/pressure-treated-lumber.oembed","provider":"IronCinder","version":"1.0","type":"link"}