{"title":"RV Air Conditioners","description":"\u003cp\u003eDedicated RV climate collection\u003c\/p\u003e\u003cp\u003eFind roof-mounted RV air conditioners with fitment and power data once model specs are finalized.\u003c\/p\u003e","products":[{"product_id":"air-dominion-13500-btu-rv-rooftop-air-conditioner-cool-only","title":"Air Dominion 13,500 BTU RV Rooftop Air Conditioner, Cool-Only","description":"\u003cp\u003eAir Dominion 13,500 BTU RV Rooftop Air Conditioner, Cool-Only is a straightforward high-airflow cooling package for RVs, campers, trailers, and food-service vehicles that already have a furnace or do not need rooftop heating. The dual-compressor design moves 470 CFM through an adjustable four-way air distribution box, and a wired thermostat controller mounts at the wall for clean cab control. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e13,500 BTU\/h cooling with dual high-efficiency compressors\u003c\/li\u003e\n\u003cli\u003e470 CFM four-way adjustable air distribution box included\u003c\/li\u003e\n\u003cli\u003eWired wall thermostat controller included\u003c\/li\u003e\n\u003cli\u003e115V, 60Hz operation for common RV shore power and generator setups\u003c\/li\u003e\n\u003cli\u003eFits the standard 14.25 x 14.25 in. RV roof opening\u003c\/li\u003e\n\u003cli\u003e59 dB operation with dehumidification mode\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (cool-only configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.5 A (published)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-ducted rooftop with air distribution box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.61 W x 14.2 H x 29.5 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir distribution box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.1 x 22.8 x 2.7 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoof opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.25 x 14.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSet temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64.4 F to 86 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRooftop unit, white shroud\u003c\/li\u003e\n\u003cli\u003eAdjustable air distribution box (ADB) with washable filter\u003c\/li\u003e\n\u003cli\u003eWired thermostat controller kit\u003c\/li\u003e\n\u003cli\u003eMounting hardware and sealing gasket\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFits standard 14.25 x 14.25 in. roof openings; air distribution box suits roofs approximately 1.5-5 in. thick.\u003c\/li\u003e\n\u003cli\u003eCool-only configuration: plan cabin heating separately.\u003c\/li\u003e\n\u003cli\u003eConfirm the 14-1\/4 in. x 14-1\/4 in. roof opening, roof structural support, and sealing plan before release.\u003c\/li\u003e\n\u003cli\u003eConfirm the 115V branch circuit, breaker sizing, and generator or shore-power capacity against the published amperage before release.\u003c\/li\u003e\n\u003cli\u003eRoof-mounted installation and electrical connection should be completed by a qualified RV service technician.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this model heat?\u003c\/strong\u003e\u003cbr\u003eNo. This is the cool-only configuration. If you need rooftop heating, the 13,500 BTU heat pump configuration covers it and is quoted the same way.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the air distribution box?\u003c\/strong\u003e\u003cbr\u003eIt is the interior ceiling unit that spreads airflow four ways, holds the filter, and connects the wired thermostat controller. It is included.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan the thermostat mount on a wall?\u003c\/strong\u003e\u003cbr\u003eYes. The included wired controller mounts at the wall for fixed cab control instead of a ceiling-only panel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat power does it need?\u003c\/strong\u003e\u003cbr\u003e115V, 60Hz single-phase, with a published 15.5 A rated current. Circuit and generator sizing are confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-13K-115-COOL-ND-submittal_26f8956e-8cce-4917-b672-8ea9d8922d81.pdf?v=1783226658\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-13K-115-COOL-ND-dimensional_2c08793c-cc9c-4a4d-ac1a-739b59a28175.pdf?v=1783226659\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-13K-115-COOL-ND-install-warranty_8d2bdc4c-7201-44db-9e0b-cf3286b9d282.pdf?v=1783226658\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"Default Title","offer_id":48918086254848,"sku":"AD-HVAC-RV-13K-115-COOL-ND","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502213845248.png?v=1783226131"},{"product_id":"air-dominion-13500-btu-rv-rooftop-air-conditioner-with-heat-pump","title":"Air Dominion 13,500 BTU RV Rooftop Air Conditioner with Heat Pump","description":"\u003cp\u003eAir Dominion 13,500 BTU RV Rooftop Air Conditioner with Heat Pump is a low-profile, non-ducted rooftop comfort system for RVs, campers, trailers, and mobile workspaces that need year-round cooling and heating from a single roof-mounted unit. The inverter compressor varies output to hold temperature with less noise and lower power draw than fixed-speed rooftop units, which matters on generator and shore-power budgets. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e13,500 BTU\/h class inverter cooling with variable 7,500-13,500 BTU\/h output\u003c\/li\u003e\n\u003cli\u003eHeat pump heating rated for ambient temperatures from 19.4 F to 109.4 F\u003c\/li\u003e\n\u003cli\u003eSlim low-profile shell about 10 in. tall reduces drag and clearance height\u003c\/li\u003e\n\u003cli\u003e115V, 60Hz operation sized for common RV shore power and generator setups\u003c\/li\u003e\n\u003cli\u003eNon-ducted ceiling assembly with washable filtration and interior controls included\u003c\/li\u003e\n\u003cli\u003eHandheld remote and Wi-Fi app control with quiet 52 dB operation\u003c\/li\u003e\n\u003cli\u003eWhite or black shroud finish selected at order\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,500-13,500 BTU\/h (inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,200-13,500 BTU\/h heat pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRunning amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.8-16.9 A cooling \/ 8.9-14.5 A heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-ducted rooftop with ceiling assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.1 W x 10.0 H x 41.6 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoof opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.25 x 14.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCeiling thickness range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.02-3.93 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat pump operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.4 F to 109.4 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRooftop unit with selected shroud color\u003c\/li\u003e\n\u003cli\u003eNon-ducted interior ceiling assembly with washable filter\u003c\/li\u003e\n\u003cli\u003eHandheld remote control\u003c\/li\u003e\n\u003cli\u003eMounting gasket and installation hardware\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFits a standard 14.25 x 14.25 in. roof vent opening on roofs 1.02-3.93 in. thick; thinner roofs need a field-supplied spacer.\u003c\/li\u003e\n\u003cli\u003eRoof must support approximately 150 lb at the mounting location.\u003c\/li\u003e\n\u003cli\u003eAllow at least 18 in. of clearance behind the unit before other rooftop equipment.\u003c\/li\u003e\n\u003cli\u003eConfirm the 14-1\/4 in. x 14-1\/4 in. roof opening, roof structural support, and sealing plan before release.\u003c\/li\u003e\n\u003cli\u003eConfirm the 115V branch circuit, breaker sizing, and generator or shore-power capacity against the published amperage before release.\u003c\/li\u003e\n\u003cli\u003eRoof-mounted installation and electrical connection should be completed by a qualified RV service technician.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003cli\u003eWi-Fi app, remote, timer, sleep, and dry modes are part of the published control feature set.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this unit both cool and heat?\u003c\/strong\u003e\u003cbr\u003eYes. It is an inverter heat pump rated to heat in ambient temperatures from 19.4 F to 109.4 F, with cooling up to 109.4 F. Below the rated range, a separate heat source is recommended.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill it fit my existing roof vent opening?\u003c\/strong\u003e\u003cbr\u003eIt mounts in the standard 14.25 x 14.25 in. RV vent opening used by most rooftop units. Openings that vary from this size need gaskets or minor enlargement, confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it compatible with ducted RV systems?\u003c\/strong\u003e\u003cbr\u003eNo. This configuration is a non-ducted unit with an interior ceiling assembly. Ducted-system requirements are routed to a different configuration during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it run on a generator?\u003c\/strong\u003e\u003cbr\u003eThe published draw is 9.8-16.9 A at 115V in cooling with a 16 A minimum circuit ampacity. Generator sizing is confirmed against your electrical setup during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-13K-115-HP-ND-submittal_cb4a29cf-c995-4f1a-b1fc-b1b2a880396b.pdf?v=1783226664\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-13K-115-HP-ND-dimensional_1becc4d9-2fae-4e97-8694-b0af16e1a152.pdf?v=1783226664\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-13K-115-HP-ND-install-warranty_cd63cbd0-0af4-4e29-a516-d2e306314eff.pdf?v=1783226664\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"White","offer_id":48918089007360,"sku":"AD-HVAC-RV-13K-115-HP-ND-WHT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Black","offer_id":48918089040128,"sku":"AD-HVAC-RV-13K-115-HP-ND-BLK","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502214598912.png?v=1783226142"},{"product_id":"air-dominion-15000-btu-rv-rooftop-air-conditioner-cool-only","title":"Air Dominion 15,000 BTU RV Rooftop Air Conditioner, Cool-Only","description":"\u003cp\u003eAir Dominion 15,000 BTU RV Rooftop Air Conditioner, Cool-Only brings the larger cooling class to rigs that handle heating separately - bigger travel trailers, toy haulers, food trucks, and work vehicles in hot climates. Dual compressors and a 470 CFM four-way air distribution box pull cabin temperature down fast, with a wired wall thermostat for everyday control. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15,000 BTU\/h cooling with dual high-efficiency compressors\u003c\/li\u003e\n\u003cli\u003e470 CFM four-way adjustable air distribution box included\u003c\/li\u003e\n\u003cli\u003eWired wall thermostat controller included\u003c\/li\u003e\n\u003cli\u003e115V, 60Hz operation with 13.5 A rated current\u003c\/li\u003e\n\u003cli\u003eFits the standard 14.25 x 14.25 in. RV roof opening\u003c\/li\u003e\n\u003cli\u003e59 dB operation with dehumidification mode\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (cool-only configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,550 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-ducted rooftop with air distribution box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.61 W x 14.2 H x 29.5 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e71.4 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir distribution box\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.1 x 22.8 x 2.7 in., 11.5 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoof opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.25 x 14.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSet temperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 F to 88 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e59 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRooftop unit, white shroud\u003c\/li\u003e\n\u003cli\u003eAdjustable air distribution box (ADB) with washable filter\u003c\/li\u003e\n\u003cli\u003eWired thermostat controller kit\u003c\/li\u003e\n\u003cli\u003eMounting hardware and sealing gasket\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFits standard 14.25 x 14.25 in. roof openings; air distribution box suits roofs approximately 1.5-5 in. thick.\u003c\/li\u003e\n\u003cli\u003eCool-only configuration: plan cabin heating separately.\u003c\/li\u003e\n\u003cli\u003eConfirm the 14-1\/4 in. x 14-1\/4 in. roof opening, roof structural support, and sealing plan before release.\u003c\/li\u003e\n\u003cli\u003eConfirm the 115V branch circuit, breaker sizing, and generator or shore-power capacity against the published amperage before release.\u003c\/li\u003e\n\u003cli\u003eRoof-mounted installation and electrical connection should be completed by a qualified RV service technician.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eHow is this different from the 13,500 BTU cool-only unit?\u003c\/strong\u003e\u003cbr\u003eSame configuration and footprint with roughly 11 percent more cooling capacity for larger or hotter spaces, at a slightly higher weight.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it include a thermostat?\u003c\/strong\u003e\u003cbr\u003eYes, a wired thermostat controller kit is included along with the air distribution box.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill it work on a 30-amp RV service?\u003c\/strong\u003e\u003cbr\u003eThe published rated current is 13.5 A at 115V, which fits typical 30 A services alongside modest loads. Final electrical review happens during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be converted to heat later?\u003c\/strong\u003e\u003cbr\u003eNo. Heating is a separate build class; if rooftop heating is needed, quote the 15,000 BTU heat pump configuration instead.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-15K-115-COOL-ND-submittal_33b96547-9c36-40e5-91bb-b1df748a6371.pdf?v=1783226669\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-15K-115-COOL-ND-dimensional_3de3a8e9-77bd-4031-aece-1c947045dfb7.pdf?v=1783226670\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-15K-115-COOL-ND-install-warranty_c7beddbc-f710-4f39-b16b-52dac33efbf2.pdf?v=1783226669\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"Default Title","offer_id":48918089203968,"sku":"AD-HVAC-RV-15K-115-COOL-ND","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502214926592.png?v=1783226152"},{"product_id":"air-dominion-15000-btu-rv-rooftop-air-conditioner-with-heat-pump","title":"Air Dominion 15,000 BTU RV Rooftop Air Conditioner with Heat Pump","description":"\u003cp\u003eAir Dominion 15,000 BTU RV Rooftop Air Conditioner with Heat Pump is the higher-capacity rooftop package for large travel trailers, fifth wheels, motorhomes, and mobile workspaces that need faster pulldown and heat-pump heating from one roof-mounted unit. A smooth low-profile shell keeps height and drag down while the non-ducted ceiling assembly delivers air directly to the cabin. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15,000 BTU\/h cooling with 12,000 BTU\/h heat pump heating\u003c\/li\u003e\n\u003cli\u003ePublished 8.5 EER efficiency with 1,550 W rated input\u003c\/li\u003e\n\u003cli\u003e115V, 60Hz operation with 12.5 A rated current fits common RV electrical setups\u003c\/li\u003e\n\u003cli\u003eQuiet operation down to 43 dB on low fan speed\u003c\/li\u003e\n\u003cli\u003eNon-ducted ceiling assembly with washable filtration and interior controls included\u003c\/li\u003e\n\u003cli\u003eHandheld remote and Wi-Fi app control\u003c\/li\u003e\n\u003cli\u003eSized for coaches and trailers up to approximately 650 sq. ft.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12,000 BTU\/h heat pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.5 EER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit breaker\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15-20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,550 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-ducted rooftop with ceiling assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e42.40 W x 12.17 H x 28.35 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100.3 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCeiling assembly\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26.25 x 19.56 x 3.77 in., 12.1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoof opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.25 x 14.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e282 \/ 253 \/ 182 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 \/ 52 \/ 43 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRooftop unit, white shroud\u003c\/li\u003e\n\u003cli\u003eNon-ducted interior ceiling assembly with washable filter\u003c\/li\u003e\n\u003cli\u003eHandheld remote control\u003c\/li\u003e\n\u003cli\u003eMounting gasket and installation hardware\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFits the standard 14.25 x 14.25 in. RV vent opening; ceiling assembly bolts suit roof thicknesses of roughly 1.2-3.1 in.\u003c\/li\u003e\n\u003cli\u003eConfirm roof structure can carry the 100 lb class rooftop unit at the opening.\u003c\/li\u003e\n\u003cli\u003eConfirm the 14-1\/4 in. x 14-1\/4 in. roof opening, roof structural support, and sealing plan before release.\u003c\/li\u003e\n\u003cli\u003eConfirm the 115V branch circuit, breaker sizing, and generator or shore-power capacity against the published amperage before release.\u003c\/li\u003e\n\u003cli\u003eRoof-mounted installation and electrical connection should be completed by a qualified RV service technician.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003cli\u003eWi-Fi app control, remote, and multi-speed fan operation are part of the published control feature set.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eHow much heating does the heat pump provide?\u003c\/strong\u003e\u003cbr\u003eThe published heating capacity is 12,000 BTU\/h in heat pump mode. Heat pumps lose capacity in deep cold, so a separate furnace remains the primary heat source for winter camping.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat breaker size does it need?\u003c\/strong\u003e\u003cbr\u003eThe published rating is a 15-20 A breaker on a 115V circuit with 12.5 A rated current. Final electrical requirements are confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it replace a standard 14 x 14 vent unit?\u003c\/strong\u003e\u003cbr\u003eYes. It mounts in the standard 14.25 x 14.25 in. opening used by most RV rooftop units.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs a wall thermostat included?\u003c\/strong\u003e\u003cbr\u003eControl is through the included ceiling assembly panel, handheld remote, and Wi-Fi app. Wall-thermostat control schemes are reviewed as a project option during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-15K-115-HP-ND-submittal_52163557-78b7-49d9-ad6f-ce84cf1b2290.pdf?v=1783226676\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-15K-115-HP-ND-dimensional_e580b041-4f4b-4016-b6d8-739f9b37eb44.pdf?v=1783226676\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-15K-115-HP-ND-install-warranty_50f2b502-9092-4652-913f-ca50e49dfb99.pdf?v=1783226676\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"Default Title","offer_id":48918089367808,"sku":"AD-HVAC-RV-15K-115-HP-ND","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502215483648.png?v=1783226173"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/collections\/rv-air-conditioners.png?v=1783054780","url":"https:\/\/ironcinder.com\/collections\/rv-air-conditioners\/voltage_110v.oembed","provider":"IronCinder","version":"1.0","type":"link"}