{"title":"VTAC","description":"\u003cp\u003eVertical terminal AC family\u003c\/p\u003e\u003cp\u003eBrowse VTAC systems for vertical terminal heating and cooling applications.\u003c\/p\u003e","products":[{"product_id":"air-dominion-12000-btu-vtac-vertical-terminal-heat-pump-208-230v","title":"Air Dominion 12,000 BTU VTAC Vertical Terminal Heat Pump, 208\/230V","description":"\u003cp\u003eAir Dominion 12,000 BTU VTAC Vertical Terminal Heat Pump is built for extended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed closet-mounted comfort equipment. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release. This vertical terminal air conditioner (VTAC) installs in a mechanical closet on an outside wall and ducts conditioned air into the living space, delivering 11,200 BTU @ 95 F cooling and heat-pump heating with selectable electric backup heat (2.5 kW \/ 3.4 kW \/ 5.0 kW). The 23 x 23 in. footprint keeps equipment out of sight for a quieter, more homelike room.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e11,200 BTU @ 95 F vertical terminal cooling\u003c\/li\u003e\n\u003cli\u003e10,400 BTU @ 47 F \/ 6,000 BTU @ 17 F (heat pump)\u003c\/li\u003e\n\u003cli\u003eSelectable electric backup heat: 2.5 kW \/ 3.4 kW \/ 5.0 kW\u003c\/li\u003e\n\u003cli\u003e12.3 SEER2 \/ 10.6 EER2 published efficiency\u003c\/li\u003e\n\u003cli\u003eConcealed closet installation with top-discharge ducting\u003c\/li\u003e\n\u003cli\u003eFree-floating chassis and gasketed wall plenum for quiet operation\u003c\/li\u003e\n\u003cli\u003e24V wall-thermostat control (thermostat quoted separately)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11,200 BTU @ 95 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating (heat pump)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,400 BTU @ 47 F \/ 6,000 BTU @ 17 F (heat pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric backup heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kW \/ 3.4 kW \/ 5.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.6 EER2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 Phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.4 kW: 19.3 A MCA, 20 A branch; 2.5 kW: 15 A circuit; 5.0 kW: 30 A circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField electrical connection per selected heater size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W x 23 D x 32 H in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation air\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 60 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-ambient heat pump operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edown to 10 F, then electric backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirmed during quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVertical terminal unit (VTAC), pre-charged and pre-wired\u003c\/li\u003e\n\u003cli\u003eSelected electric backup heater (per configuration)\u003c\/li\u003e\n\u003cli\u003eInstallation and service documentation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalls in a closet-style enclosure on an outside wall; unit slides into the wall plenum and seals with a gasket.\u003c\/li\u003e\n\u003cli\u003eArchitectural exterior louver, return-air grille, supply duct transition, and support platform are project-side items confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eProvide a dedicated circuit sized to the selected electric heater; wall thermostat (24V single-stage) is required and quoted separately.\u003c\/li\u003e\n\u003cli\u003eConfirm condensate routing (including secondary drain on larger cabinets) before release.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFinal warranty packet and accessory scope are confirmed during quote review before release.\u003c\/li\u003e\n\u003cli\u003eUse the Air Dominion installation and warranty reference to align sleeve, grille, electrical, and thermostat scope before ordering.\u003c\/li\u003e\n\u003cli\u003eRegistered-coverage options are reviewed with the final quote.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this fit a standard 42 x 16 in. PTAC wall sleeve?\u003c\/strong\u003e\u003cbr\u003eNo. VTAC equipment installs vertically in a closet enclosure on an outside wall with a gasketed wall plenum and ducted discharge - it does not use the horizontal 42 x 16 in. PTAC sleeve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat kind of projects is this built for?\u003c\/strong\u003e\u003cbr\u003eExtended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed, room-by-room packaged comfort with a homelike interior appearance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need a wall thermostat?\u003c\/strong\u003e\u003cbr\u003eYes. A single-stage 24V wall thermostat is required and is not included; it is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat should be confirmed before ordering?\u003c\/strong\u003e\u003cbr\u003eCloset dimensions and platform, exterior louver and return-air grille selection, electric heater size and circuit, condensate routing, and voltage - all confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-12K-230-submittal_f600b659-f47f-4d1e-a9aa-484949c1f86f.pdf?v=1783049488\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-12K-230-dimensional_b69ed5e7-fa4b-4393-a45d-ae912719ef09.pdf?v=1783049488\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-12K-230-install-warranty_b762bd4e-2a70-4704-9946-23ee85be5513.pdf?v=1783049489\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"2.5 kW","offer_id":48918046605568,"sku":"AD-HVAC-VTAC-12K-23025KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3.4 kW","offer_id":48918046638336,"sku":"AD-HVAC-VTAC-12K-23034KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5.0 kW","offer_id":48918046671104,"sku":"AD-HVAC-VTAC-12K-23050KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_0f33b194-1327-4442-8bed-ed4932ddc730.png?v=1783047796"},{"product_id":"air-dominion-18000-btu-vtac-vertical-terminal-heat-pump-208-230v","title":"Air Dominion 18,000 BTU VTAC Vertical Terminal Heat Pump, 208\/230V","description":"\u003cp\u003eAir Dominion 18,000 BTU VTAC Vertical Terminal Heat Pump is built for extended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed closet-mounted comfort equipment. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release. This vertical terminal air conditioner (VTAC) installs in a mechanical closet on an outside wall and ducts conditioned air into the living space, delivering 17,800 BTU @ 95 F cooling and heat-pump heating with selectable electric backup heat (2.5 kW \/ 3.4 kW \/ 5.0 kW \/ 7.5 kW). The 23 x 23 in. footprint keeps equipment out of sight for a quieter, more homelike room.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e17,800 BTU @ 95 F vertical terminal cooling\u003c\/li\u003e\n\u003cli\u003e16,200 BTU @ 47 F \/ 9,800 BTU @ 17 F (heat pump)\u003c\/li\u003e\n\u003cli\u003eSelectable electric backup heat: 2.5 kW \/ 3.4 kW \/ 5.0 kW \/ 7.5 kW\u003c\/li\u003e\n\u003cli\u003e12.1 SEER2 \/ 10.6 EER2 published efficiency\u003c\/li\u003e\n\u003cli\u003eConcealed closet installation with top-discharge ducting\u003c\/li\u003e\n\u003cli\u003eFree-floating chassis and gasketed wall plenum for quiet operation\u003c\/li\u003e\n\u003cli\u003e24V wall-thermostat control (thermostat quoted separately)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17,800 BTU @ 95 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating (heat pump)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16,200 BTU @ 47 F \/ 9,800 BTU @ 17 F (heat pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric backup heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kW \/ 3.4 kW \/ 5.0 kW \/ 7.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.6 EER2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 Phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kW: 15 A; 3.4 kW: 20 A; 5.0 kW: 30 A; 7.5 kW: 45 A circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField electrical connection per selected heater size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W x 23 D x 47 H in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e560 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation air\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 60 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-ambient heat pump operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edown to 10 F, then electric backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary drain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003egravity-fed secondary drain used on 18K\/24K class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirmed during quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVertical terminal unit (VTAC), pre-charged and pre-wired\u003c\/li\u003e\n\u003cli\u003eSelected electric backup heater (per configuration)\u003c\/li\u003e\n\u003cli\u003eInstallation and service documentation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalls in a closet-style enclosure on an outside wall; unit slides into the wall plenum and seals with a gasket.\u003c\/li\u003e\n\u003cli\u003eArchitectural exterior louver, return-air grille, supply duct transition, and support platform are project-side items confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eProvide a dedicated circuit sized to the selected electric heater; wall thermostat (24V single-stage) is required and quoted separately.\u003c\/li\u003e\n\u003cli\u003eConfirm condensate routing (including secondary drain on larger cabinets) before release.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFinal warranty packet and accessory scope are confirmed during quote review before release.\u003c\/li\u003e\n\u003cli\u003eUse the Air Dominion installation and warranty reference to align sleeve, grille, electrical, and thermostat scope before ordering.\u003c\/li\u003e\n\u003cli\u003eRegistered-coverage options are reviewed with the final quote.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this fit a standard 42 x 16 in. PTAC wall sleeve?\u003c\/strong\u003e\u003cbr\u003eNo. VTAC equipment installs vertically in a closet enclosure on an outside wall with a gasketed wall plenum and ducted discharge - it does not use the horizontal 42 x 16 in. PTAC sleeve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat kind of projects is this built for?\u003c\/strong\u003e\u003cbr\u003eExtended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed, room-by-room packaged comfort with a homelike interior appearance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need a wall thermostat?\u003c\/strong\u003e\u003cbr\u003eYes. A single-stage 24V wall thermostat is required and is not included; it is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat should be confirmed before ordering?\u003c\/strong\u003e\u003cbr\u003eCloset dimensions and platform, exterior louver and return-air grille selection, electric heater size and circuit, condensate routing, and voltage - all confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-18K-230-submittal_42a10f9d-3980-42fc-a821-c3ad90e48772.pdf?v=1783049495\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-18K-230-dimensional_ee0cb37e-e4ec-42cf-842a-a228236a49c5.pdf?v=1783049495\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-18K-230-install-warranty_60e1b478-ab9e-4b47-8d1e-199696fc56ee.pdf?v=1783049494\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"2.5 kW","offer_id":48918046736640,"sku":"AD-HVAC-VTAC-18K-23025KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3.4 kW","offer_id":48918046769408,"sku":"AD-HVAC-VTAC-18K-23034KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5.0 kW","offer_id":48918046802176,"sku":"AD-HVAC-VTAC-18K-23050KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918046834944,"sku":"AD-HVAC-VTAC-18K-23075KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_1fa078f7-835c-4bd1-b030-4c7c4f31d7b5.png?v=1783047815"},{"product_id":"air-dominion-24000-btu-vtac-vertical-terminal-heat-pump-208-230v","title":"Air Dominion 24,000 BTU VTAC Vertical Terminal Heat Pump, 208\/230V","description":"\u003cp\u003eAir Dominion 24,000 BTU VTAC Vertical Terminal Heat Pump is built for extended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed closet-mounted comfort equipment. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release. This vertical terminal air conditioner (VTAC) installs in a mechanical closet on an outside wall and ducts conditioned air into the living space, delivering 22,600 BTU @ 95 F cooling and heat-pump heating with selectable electric backup heat (2.5 kW \/ 3.4 kW \/ 5.0 kW \/ 7.5 kW \/ 10.0 kW). The 23 x 23 in. footprint keeps equipment out of sight for a quieter, more homelike room.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e22,600 BTU @ 95 F vertical terminal cooling\u003c\/li\u003e\n\u003cli\u003e19,500 BTU @ 47 F \/ 12,400 BTU @ 17 F (heat pump)\u003c\/li\u003e\n\u003cli\u003eSelectable electric backup heat: 2.5 kW \/ 3.4 kW \/ 5.0 kW \/ 7.5 kW \/ 10.0 kW\u003c\/li\u003e\n\u003cli\u003e12.1 SEER2 \/ 10.6 EER2 published efficiency\u003c\/li\u003e\n\u003cli\u003eConcealed closet installation with top-discharge ducting\u003c\/li\u003e\n\u003cli\u003eFree-floating chassis and gasketed wall plenum for quiet operation\u003c\/li\u003e\n\u003cli\u003e24V wall-thermostat control (thermostat quoted separately)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22,600 BTU @ 95 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating (heat pump)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,500 BTU @ 47 F \/ 12,400 BTU @ 17 F (heat pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric backup heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kW \/ 3.4 kW \/ 5.0 kW \/ 7.5 kW \/ 10.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.6 EER2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 Phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kW: 20 A; 3.4 kW: 25 A; 5.0 kW: 30 A; 7.5 kW: 45 A; 10.0 kW: 60 A circuit class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField electrical connection per selected heater size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W x 23 D x 52 H in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e580 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation air\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 60 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-ambient heat pump operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edown to 10 F, then electric backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary drain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003egravity-fed secondary drain used on 18K\/24K class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirmed during quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVertical terminal unit (VTAC), pre-charged and pre-wired\u003c\/li\u003e\n\u003cli\u003eSelected electric backup heater (per configuration)\u003c\/li\u003e\n\u003cli\u003eInstallation and service documentation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalls in a closet-style enclosure on an outside wall; unit slides into the wall plenum and seals with a gasket.\u003c\/li\u003e\n\u003cli\u003eArchitectural exterior louver, return-air grille, supply duct transition, and support platform are project-side items confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eProvide a dedicated circuit sized to the selected electric heater; wall thermostat (24V single-stage) is required and quoted separately.\u003c\/li\u003e\n\u003cli\u003eConfirm condensate routing (including secondary drain on larger cabinets) before release.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFinal warranty packet and accessory scope are confirmed during quote review before release.\u003c\/li\u003e\n\u003cli\u003eUse the Air Dominion installation and warranty reference to align sleeve, grille, electrical, and thermostat scope before ordering.\u003c\/li\u003e\n\u003cli\u003eRegistered-coverage options are reviewed with the final quote.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this fit a standard 42 x 16 in. PTAC wall sleeve?\u003c\/strong\u003e\u003cbr\u003eNo. VTAC equipment installs vertically in a closet enclosure on an outside wall with a gasketed wall plenum and ducted discharge - it does not use the horizontal 42 x 16 in. PTAC sleeve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat kind of projects is this built for?\u003c\/strong\u003e\u003cbr\u003eExtended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed, room-by-room packaged comfort with a homelike interior appearance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need a wall thermostat?\u003c\/strong\u003e\u003cbr\u003eYes. A single-stage 24V wall thermostat is required and is not included; it is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat should be confirmed before ordering?\u003c\/strong\u003e\u003cbr\u003eCloset dimensions and platform, exterior louver and return-air grille selection, electric heater size and circuit, condensate routing, and voltage - all confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-24K-230-submittal_c5d78e91-6629-41e7-aa23-d2f5fe0bac97.pdf?v=1783049575\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-24K-230-dimensional_34fb42e7-5ac4-4a14-876d-0629cfa3e88e.pdf?v=1783049575\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-24K-230-install-warranty_1dcb4115-88fe-4e66-896b-d0d0af43fc88.pdf?v=1783049576\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"2.5 kW","offer_id":48918046998784,"sku":"AD-HVAC-VTAC-24K-23025KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3.4 kW","offer_id":48918047031552,"sku":"AD-HVAC-VTAC-24K-23034KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5.0 kW","offer_id":48918047064320,"sku":"AD-HVAC-VTAC-24K-23050KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918047097088,"sku":"AD-HVAC-VTAC-24K-23075KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10.0 kW","offer_id":48918047129856,"sku":"AD-HVAC-VTAC-24K-230100KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_25993a8e-f580-4226-b784-380a59d99149.png?v=1783047819"},{"product_id":"air-dominion-9000-btu-vtac-vertical-terminal-heat-pump-208-230v","title":"Air Dominion 9,000 BTU VTAC Vertical Terminal Heat Pump, 208\/230V","description":"\u003cp\u003eAir Dominion 9,000 BTU VTAC Vertical Terminal Heat Pump is built for extended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed closet-mounted comfort equipment. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release. This vertical terminal air conditioner (VTAC) installs in a mechanical closet on an outside wall and ducts conditioned air into the living space, delivering 9,400 BTU @ 95 F cooling and heat-pump heating with selectable electric backup heat (2.5 kW \/ 3.4 kW \/ 5.0 kW). The 23 x 23 in. footprint keeps equipment out of sight for a quieter, more homelike room.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e9,400 BTU @ 95 F vertical terminal cooling\u003c\/li\u003e\n\u003cli\u003e8,600 BTU @ 47 F \/ 4,900 BTU @ 17 F (heat pump)\u003c\/li\u003e\n\u003cli\u003eSelectable electric backup heat: 2.5 kW \/ 3.4 kW \/ 5.0 kW\u003c\/li\u003e\n\u003cli\u003e12.3 SEER2 \/ 10.6 EER2 published efficiency\u003c\/li\u003e\n\u003cli\u003eConcealed closet installation with top-discharge ducting\u003c\/li\u003e\n\u003cli\u003eFree-floating chassis and gasketed wall plenum for quiet operation\u003c\/li\u003e\n\u003cli\u003e24V wall-thermostat control (thermostat quoted separately)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9,400 BTU @ 95 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating (heat pump)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,600 BTU @ 47 F \/ 4,900 BTU @ 17 F (heat pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric backup heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kW \/ 3.4 kW \/ 5.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.6 EER2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 Phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kW: 15 A circuit; 3.4 kW: 20 A circuit; 5.0 kW: 30 A circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField electrical connection per selected heater size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W x 23 D x 32 H in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation air\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 60 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-ambient heat pump operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edown to 10 F, then electric backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirmed during quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVertical terminal unit (VTAC), pre-charged and pre-wired\u003c\/li\u003e\n\u003cli\u003eSelected electric backup heater (per configuration)\u003c\/li\u003e\n\u003cli\u003eInstallation and service documentation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalls in a closet-style enclosure on an outside wall; unit slides into the wall plenum and seals with a gasket.\u003c\/li\u003e\n\u003cli\u003eArchitectural exterior louver, return-air grille, supply duct transition, and support platform are project-side items confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eProvide a dedicated circuit sized to the selected electric heater; wall thermostat (24V single-stage) is required and quoted separately.\u003c\/li\u003e\n\u003cli\u003eConfirm condensate routing (including secondary drain on larger cabinets) before release.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFinal warranty packet and accessory scope are confirmed during quote review before release.\u003c\/li\u003e\n\u003cli\u003eUse the Air Dominion installation and warranty reference to align sleeve, grille, electrical, and thermostat scope before ordering.\u003c\/li\u003e\n\u003cli\u003eRegistered-coverage options are reviewed with the final quote.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this fit a standard 42 x 16 in. PTAC wall sleeve?\u003c\/strong\u003e\u003cbr\u003eNo. VTAC equipment installs vertically in a closet enclosure on an outside wall with a gasketed wall plenum and ducted discharge - it does not use the horizontal 42 x 16 in. PTAC sleeve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat kind of projects is this built for?\u003c\/strong\u003e\u003cbr\u003eExtended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed, room-by-room packaged comfort with a homelike interior appearance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need a wall thermostat?\u003c\/strong\u003e\u003cbr\u003eYes. A single-stage 24V wall thermostat is required and is not included; it is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat should be confirmed before ordering?\u003c\/strong\u003e\u003cbr\u003eCloset dimensions and platform, exterior louver and return-air grille selection, electric heater size and circuit, condensate routing, and voltage - all confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-9K-230-submittal_decc66c1-cc54-4cd6-8293-3a1fb814913e.pdf?v=1783049656\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-9K-230-dimensional_5bde05cf-855d-4bbc-97db-a170a0a3271a.pdf?v=1783049656\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-9K-230-install-warranty_289a74fe-812d-4974-a2cd-113a073e2b4f.pdf?v=1783049656\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"2.5 kW","offer_id":48918047293696,"sku":"AD-HVAC-VTAC-9K-23025KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3.4 kW","offer_id":48918047326464,"sku":"AD-HVAC-VTAC-9K-23034KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5.0 kW","offer_id":48918047359232,"sku":"AD-HVAC-VTAC-9K-23050KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_de822419-9c6e-4b92-9e36-43a007261cef.png?v=1783047823"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/collections\/vtac.png?v=1783054969","url":"https:\/\/ironcinder.com\/collections\/vtac\/refrigerant_r-32.oembed","provider":"IronCinder","version":"1.0","type":"link"}