{"product_id":"air-dominion-13500-btu-rv-rooftop-air-conditioner-with-heat-pump","title":"Air Dominion 13,500 BTU RV Rooftop Air Conditioner with Heat Pump","description":"\u003cp\u003eAir Dominion 13,500 BTU RV Rooftop Air Conditioner with Heat Pump is a low-profile, non-ducted rooftop comfort system for RVs, campers, trailers, and mobile workspaces that need year-round cooling and heating from a single roof-mounted unit. The inverter compressor varies output to hold temperature with less noise and lower power draw than fixed-speed rooftop units, which matters on generator and shore-power budgets. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e13,500 BTU\/h class inverter cooling with variable 7,500-13,500 BTU\/h output\u003c\/li\u003e\n\u003cli\u003eHeat pump heating rated for ambient temperatures from 19.4 F to 109.4 F\u003c\/li\u003e\n\u003cli\u003eSlim low-profile shell about 10 in. tall reduces drag and clearance height\u003c\/li\u003e\n\u003cli\u003e115V, 60Hz operation sized for common RV shore power and generator setups\u003c\/li\u003e\n\u003cli\u003eNon-ducted ceiling assembly with washable filtration and interior controls included\u003c\/li\u003e\n\u003cli\u003eHandheld remote and Wi-Fi app control with quiet 52 dB operation\u003c\/li\u003e\n\u003cli\u003eWhite or black shroud finish selected at order\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,500-13,500 BTU\/h (inverter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7,200-13,500 BTU\/h heat pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115V, 60Hz, 1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRunning amperage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.8-16.9 A cooling \/ 8.9-14.5 A heating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum circuit ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-ducted rooftop with ceiling assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e29.1 W x 10.0 H x 41.6 D in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRooftop unit weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88.2 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoof opening\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.25 x 14.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCeiling thickness range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.02-3.93 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat pump operating range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.4 F to 109.4 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e52 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRooftop unit with selected shroud color\u003c\/li\u003e\n\u003cli\u003eNon-ducted interior ceiling assembly with washable filter\u003c\/li\u003e\n\u003cli\u003eHandheld remote control\u003c\/li\u003e\n\u003cli\u003eMounting gasket and installation hardware\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFits a standard 14.25 x 14.25 in. roof vent opening on roofs 1.02-3.93 in. thick; thinner roofs need a field-supplied spacer.\u003c\/li\u003e\n\u003cli\u003eRoof must support approximately 150 lb at the mounting location.\u003c\/li\u003e\n\u003cli\u003eAllow at least 18 in. of clearance behind the unit before other rooftop equipment.\u003c\/li\u003e\n\u003cli\u003eConfirm the 14-1\/4 in. x 14-1\/4 in. roof opening, roof structural support, and sealing plan before release.\u003c\/li\u003e\n\u003cli\u003eConfirm the 115V branch circuit, breaker sizing, and generator or shore-power capacity against the published amperage before release.\u003c\/li\u003e\n\u003cli\u003eRoof-mounted installation and electrical connection should be completed by a qualified RV service technician.\u003c\/li\u003e\n\u003cli\u003eImages are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final model, electrical requirements, accessories, warranty coverage, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003ePublished warranty terms are issued with the final quote packet.\u003c\/li\u003e\n\u003cli\u003eWi-Fi app, remote, timer, sleep, and dry modes are part of the published control feature set.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this unit both cool and heat?\u003c\/strong\u003e\u003cbr\u003eYes. It is an inverter heat pump rated to heat in ambient temperatures from 19.4 F to 109.4 F, with cooling up to 109.4 F. Below the rated range, a separate heat source is recommended.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill it fit my existing roof vent opening?\u003c\/strong\u003e\u003cbr\u003eIt mounts in the standard 14.25 x 14.25 in. RV vent opening used by most rooftop units. Openings that vary from this size need gaskets or minor enlargement, confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it compatible with ducted RV systems?\u003c\/strong\u003e\u003cbr\u003eNo. This configuration is a non-ducted unit with an interior ceiling assembly. Ducted-system requirements are routed to a different configuration during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it run on a generator?\u003c\/strong\u003e\u003cbr\u003eThe published draw is 9.8-16.9 A at 115V in cooling with a 16 A minimum circuit ampacity. Generator sizing is confirmed against your electrical setup during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-13K-115-HP-ND-submittal_cb4a29cf-c995-4f1a-b1fc-b1b2a880396b.pdf?v=1783226664\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-13K-115-HP-ND-dimensional_1becc4d9-2fae-4e97-8694-b0af16e1a152.pdf?v=1783226664\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-RV-13K-115-HP-ND-install-warranty_cd63cbd0-0af4-4e29-a516-d2e306314eff.pdf?v=1783226664\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"White","offer_id":48918089007360,"sku":"AD-HVAC-RV-13K-115-HP-ND-WHT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Black","offer_id":48918089040128,"sku":"AD-HVAC-RV-13K-115-HP-ND-BLK","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502214598912.png?v=1783226142","url":"https:\/\/ironcinder.com\/products\/air-dominion-13500-btu-rv-rooftop-air-conditioner-with-heat-pump","provider":"IronCinder","version":"1.0","type":"link"}