{"product_id":"air-dominion-24000-btu-vtac-vertical-terminal-heat-pump-208-230v","title":"Air Dominion 24,000 BTU VTAC Vertical Terminal Heat Pump, 208\/230V","description":"\u003cp\u003eAir Dominion 24,000 BTU VTAC Vertical Terminal Heat Pump is built for extended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed closet-mounted comfort equipment. This Air Dominion quoting record is presented as a reviewed product configuration, with final equipment configuration confirmed during quote review before release. This vertical terminal air conditioner (VTAC) installs in a mechanical closet on an outside wall and ducts conditioned air into the living space, delivering 22,600 BTU @ 95 F cooling and heat-pump heating with selectable electric backup heat (2.5 kW \/ 3.4 kW \/ 5.0 kW \/ 7.5 kW \/ 10.0 kW). The 23 x 23 in. footprint keeps equipment out of sight for a quieter, more homelike room.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e22,600 BTU @ 95 F vertical terminal cooling\u003c\/li\u003e\n\u003cli\u003e19,500 BTU @ 47 F \/ 12,400 BTU @ 17 F (heat pump)\u003c\/li\u003e\n\u003cli\u003eSelectable electric backup heat: 2.5 kW \/ 3.4 kW \/ 5.0 kW \/ 7.5 kW \/ 10.0 kW\u003c\/li\u003e\n\u003cli\u003e12.1 SEER2 \/ 10.6 EER2 published efficiency\u003c\/li\u003e\n\u003cli\u003eConcealed closet installation with top-discharge ducting\u003c\/li\u003e\n\u003cli\u003eFree-floating chassis and gasketed wall plenum for quiet operation\u003c\/li\u003e\n\u003cli\u003e24V wall-thermostat control (thermostat quoted separately)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCooling capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22,600 BTU @ 95 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating (heat pump)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19,500 BTU @ 47 F \/ 12,400 BTU @ 17 F (heat pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectric backup heat options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kW \/ 3.4 kW \/ 5.0 kW \/ 7.5 kW \/ 10.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10.6 EER2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e208\/230V, 1 Phase, 60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kW: 20 A; 3.4 kW: 25 A; 5.0 kW: 30 A; 7.5 kW: 45 A; 10.0 kW: 60 A circuit class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField electrical connection per selected heater size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRefrigerant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eR-32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 W x 23 D x 52 H in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHSPF2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAirflow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e580 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVentilation air\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 60 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLow-ambient heat pump operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003edown to 10 F, then electric backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecondary drain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003egravity-fed secondary drain used on 18K\/24K class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfirmed during quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eVertical terminal unit (VTAC), pre-charged and pre-wired\u003c\/li\u003e\n\u003cli\u003eSelected electric backup heater (per configuration)\u003c\/li\u003e\n\u003cli\u003eInstallation and service documentation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalls in a closet-style enclosure on an outside wall; unit slides into the wall plenum and seals with a gasket.\u003c\/li\u003e\n\u003cli\u003eArchitectural exterior louver, return-air grille, supply duct transition, and support platform are project-side items confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eProvide a dedicated circuit sized to the selected electric heater; wall thermostat (24V single-stage) is required and quoted separately.\u003c\/li\u003e\n\u003cli\u003eConfirm condensate routing (including secondary drain on larger cabinets) before release.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFinal warranty packet and accessory scope are confirmed during quote review before release.\u003c\/li\u003e\n\u003cli\u003eUse the Air Dominion installation and warranty reference to align sleeve, grille, electrical, and thermostat scope before ordering.\u003c\/li\u003e\n\u003cli\u003eRegistered-coverage options are reviewed with the final quote.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this fit a standard 42 x 16 in. PTAC wall sleeve?\u003c\/strong\u003e\u003cbr\u003eNo. VTAC equipment installs vertically in a closet enclosure on an outside wall with a gasketed wall plenum and ducted discharge - it does not use the horizontal 42 x 16 in. PTAC sleeve.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat kind of projects is this built for?\u003c\/strong\u003e\u003cbr\u003eExtended-stay hospitality, multifamily, student housing, and assisted-living projects that want concealed, room-by-room packaged comfort with a homelike interior appearance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it need a wall thermostat?\u003c\/strong\u003e\u003cbr\u003eYes. A single-stage 24V wall thermostat is required and is not included; it is confirmed during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat should be confirmed before ordering?\u003c\/strong\u003e\u003cbr\u003eCloset dimensions and platform, exterior louver and return-air grille selection, electric heater size and circuit, condensate routing, and voltage - all confirmed during quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-24K-230-submittal_c5d78e91-6629-41e7-aa23-d2f5fe0bac97.pdf?v=1783049575\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-24K-230-dimensional_34fb42e7-5ac4-4a14-876d-0629cfa3e88e.pdf?v=1783049575\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-VTAC-24K-230-install-warranty_1dcb4115-88fe-4e66-896b-d0d0af43fc88.pdf?v=1783049576\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"2.5 kW","offer_id":48918046998784,"sku":"AD-HVAC-VTAC-24K-23025KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3.4 kW","offer_id":48918047031552,"sku":"AD-HVAC-VTAC-24K-23034KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"5.0 kW","offer_id":48918047064320,"sku":"AD-HVAC-VTAC-24K-23050KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"7.5 kW","offer_id":48918047097088,"sku":"AD-HVAC-VTAC-24K-23075KW","price":0.0,"currency_code":"USD","in_stock":true},{"title":"10.0 kW","offer_id":48918047129856,"sku":"AD-HVAC-VTAC-24K-230100KW","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_25993a8e-f580-4226-b784-380a59d99149.png?v=1783047819","url":"https:\/\/ironcinder.com\/products\/air-dominion-24000-btu-vtac-vertical-terminal-heat-pump-208-230v","provider":"IronCinder","version":"1.0","type":"link"}