{"product_id":"air-dominion-mini-split-line-set-installation-kit","title":"Air Dominion Mini Split Line Set Installation Kit","description":"\u003cp\u003eAir Dominion Mini Split Line Set Installation Kit bundles the three run-length items every mini split install consumes together: the insulated flared line set, control wire cut to the same length, and a 20 ft condensate drain line. Pick the line size that matches the system's labeled connections and the length that matches the route - one kit replaces three separate line items on the quote. This Air Dominion quoting record is presented as a reviewed accessory configuration, with final configuration confirmed during quote review before release.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulated flared line set in the ordered size and length\u003c\/li\u003e\n\u003cli\u003e14\/4 control wire matched to the line set length\u003c\/li\u003e\n\u003cli\u003e20 ft of 5\/8 in. condensate drain line included\u003c\/li\u003e\n\u003cli\u003eLine sizes for every Air Dominion single-zone class: 1\/4 x 3\/8 (9K-12K), 1\/4 x 1\/2 (18K), 3\/8 x 5\/8 (24K)\u003c\/li\u003e\n\u003cli\u003eLengths from 15 to 50 ft to match the routed run\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine set\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInsulated pair, flared ends, ordered size and length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine size options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 x 3\/8 \/ 1\/4 x 1\/2 \/ 3\/8 x 5\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 \/ 25 \/ 30 \/ 35 \/ 50 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl wire\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\/4 stranded, matches line set length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\/8 in. x 20 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Equipment\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInsulated line set (liquid + suction pair, flared)\u003c\/li\u003e\n\u003cli\u003eControl wire, same length as line set\u003c\/li\u003e\n\u003cli\u003e20 ft condensate drain line\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eChoose line size from the unit's labeled connections: 1\/4 x 3\/8 for 9K-12K, 1\/4 x 1\/2 for 18K, 3\/8 x 5\/8 for 24K standard chassis - confirmed during quote review.\u003c\/li\u003e\n\u003cli\u003eKeep total run and rise within the connected system's published piping limits.\u003c\/li\u003e\n\u003cli\u003eRefrigerant-side work including flaring, evacuation, and charging verification should be completed by a qualified HVAC professional.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrepared for Air Dominion quote review. Final accessory configuration, coverage terms, and installation documents are confirmed before release.\u003c\/li\u003e\n\u003cli\u003eAccessory coverage follows the published Air Dominion accessory support terms confirmed during quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eHow do I pick the right kit for my system?\u003c\/strong\u003e\u003cbr\u003eMatch line size to capacity class - 1\/4 x 3\/8 for Air Dominion 9K and 12K, 1\/4 x 1\/2 for 18K, and 3\/8 x 5\/8 for 24K standard chassis - then pick the length that covers the routed run. Sizes are confirmed against the unit label during quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is in the kit besides the line set?\u003c\/strong\u003e\u003cbr\u003eControl wire cut to the same length as the line set and a 20 ft condensate drain line - the two other run-length consumables of a standard install.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it include the disconnect and whip?\u003c\/strong\u003e\u003cbr\u003eNo - electrical-side items are in the Condenser Electrical Accessory Kit or the Single-Zone Complete Installation Kit.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-MS-INSTALLKIT-IND-submittal_9fab61ab-6e31-4dd0-8250-5761fcf2d460.pdf?v=1783226698\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-MS-INSTALLKIT-IND-dimensional_f137c00b-7705-4c2c-88a3-646271a460cf.pdf?v=1783226698\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/AD-HVAC-ACC-MS-INSTALLKIT-IND-install-warranty_566afc07-ff0c-4ff5-b709-5eef79e90285.pdf?v=1783226697\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Air Dominion","offers":[{"title":"1\/4 x 3\/8 in. \/ 15 ft","offer_id":48918102933760,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1438-15","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/4 x 3\/8 in. \/ 25 ft","offer_id":48918102966528,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1438-25","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/4 x 3\/8 in. \/ 30 ft","offer_id":48918102999296,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1438-30","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/4 x 3\/8 in. \/ 35 ft","offer_id":48918103032064,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1438-35","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/4 x 3\/8 in. \/ 50 ft","offer_id":48918103064832,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1438-50","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/4 x 1\/2 in. \/ 15 ft","offer_id":48918103097600,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1412-15","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/4 x 1\/2 in. \/ 25 ft","offer_id":48918103130368,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1412-25","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/4 x 1\/2 in. \/ 30 ft","offer_id":48918103163136,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1412-30","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/4 x 1\/2 in. \/ 35 ft","offer_id":48918103195904,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1412-35","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1\/4 x 1\/2 in. \/ 50 ft","offer_id":48918103228672,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-1412-50","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/8 x 5\/8 in. \/ 15 ft","offer_id":48918103261440,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-3858-15","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/8 x 5\/8 in. \/ 25 ft","offer_id":48918103294208,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-3858-25","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/8 x 5\/8 in. \/ 30 ft","offer_id":48918103326976,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-3858-30","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/8 x 5\/8 in. \/ 35 ft","offer_id":48918103359744,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-3858-35","price":0.0,"currency_code":"USD","in_stock":true},{"title":"3\/8 x 5\/8 in. \/ 50 ft","offer_id":48918103392512,"sku":"AD-HVAC-ACC-MS-INSTALLKIT-IND-3858-50","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/38502238486784.png?v=1783226196","url":"https:\/\/ironcinder.com\/products\/air-dominion-mini-split-line-set-installation-kit","provider":"IronCinder","version":"1.0","type":"link"}