{"product_id":"light-archon-aegis-20a-single-pole-circuit-breaker","title":"Light Archon Aegis 20A Single-Pole Circuit Breaker","description":"\u003cp\u003eLight Archon Aegis breakers put the everyday 20 A single-pole slot on one platform in the industry-standard 1 in. plug-on format. Protection levels run from the standard thermal magnetic unit to a tandem two-circuit unit, an AFCI unit, and a dual function AF\/GF unit, so one line item covers the full branch circuit schedule. Every unit is quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eThe standard unit trips to the center position on overload or fault current, so a tripped handle reads at a glance. The tandem unit fits two 20 A circuits in one pole space where the panel label permits it. AFCI and dual function units add arc fault and combined arc plus ground fault protection for the dwelling circuits the NEC calls out. Interrupt rating is 10 kA across the line, and terminations accept #14-4 AWG Cu\/Al conductors at 60 C or 75 C.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e20 A single-pole platform in the 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003eStandard, tandem two-circuit, AFCI, and dual function AF\/GF levels\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip unit; trips to center for clear fault indication\u003c\/li\u003e\n\u003cli\u003ePlug-on bus connection with no mounting hardware\u003c\/li\u003e\n\u003cli\u003eTerminations accept #14-4 AWG Cu\/Al conductors\u003c\/li\u003e\n\u003cli\u003eUL Listed and ANSI certified platform\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, 1 in. format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V standard and tandem units; AFCI and dual function units rated 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, tandem two-circuit, AFCI, dual function AF\/GF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e#14-4 AWG Cu\/Al at 60 C or 75 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, ANSI certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne breaker per unit, protection level per selected variant\u003c\/li\u003e\n\u003cli\u003eAFCI and dual function units include their factory pigtail or plug-on neutral hardware\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eAFCI and GFCI protection locations follow the NEC edition adopted in your jurisdiction\u003c\/li\u003e\n\u003cli\u003eTandem units go only in slots the panel label permits\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich protection level do I need?\u003c\/strong\u003e\u003cbr\u003eStandard units cover most branch circuits. The NEC calls for AFCI protection in most dwelling living areas and combined AF\/GF units where the plan calls for both arc and ground fault protection on one circuit. Your electrician and the trade desk confirm the schedule at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I use the tandem unit anywhere in the panel?\u003c\/strong\u003e\u003cbr\u003eNo. Tandem units belong only in slots the panel label lists as tandem-permitted. The panel schedule is checked at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-AEGIS-submittal.pdf?v=1783306765\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-AEGIS-dimensional.pdf?v=1783306765\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-AEGIS-install-warranty.pdf?v=1783306765\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Standard","offer_id":48934490571008,"sku":"LA-LGT-BRK-A20-AEGIS-STD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Tandem Two Circuit","offer_id":48934490603776,"sku":"LA-LGT-BRK-A20-AEGIS-TDM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"AFCI","offer_id":48934490636544,"sku":"LA-LGT-BRK-A20-AEGIS-AFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Dual Function AF GF","offer_id":48934490669312,"sku":"LA-LGT-BRK-A20-AEGIS-DFC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_1d8eedc1-1110-4ea7-bcf6-408c130f8a30.png?v=1783306374","url":"https:\/\/ironcinder.com\/products\/light-archon-aegis-20a-single-pole-circuit-breaker","provider":"IronCinder","version":"1.0","type":"link"}