{"product_id":"light-archon-citadel-20a-circuit-breaker-platform","title":"Light Archon Citadel 20A Circuit Breaker Platform","description":"\u003cp\u003eLight Archon Citadel breakers put the full 20 A branch schedule on one platform in the industry-standard 1 in. plug-on format. Configurations run single-pole, tandem two-circuit, and 2-pole; protection levels run from standard thermal magnetic units through AFCI, GFCI, and dual function AF\/GF electronics, with the AFCI and dual function levels offered in pigtail or plug-on neutral connection to match the panel. Every unit is quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eStandard, tandem, and 2-pole units use a thermal magnetic trip rated 120\/240V; the tandem fits two 20 A circuits in one pole space where the panel label permits, and the 2-pole unit serves 240V loads across two spaces. AFCI units add combination arc fault protection for dwelling living areas, GFCI units add Class A ground fault protection, and dual function units combine both behind a single reset. Plug-on neutral versions land the neutral through the mounting foot on panels with a plug-on neutral bus, eliminating the pigtail and keeping gutter space clear. Interrupt rating is 10 kA across the line.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e20 A platform in the 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003eSingle-pole, tandem two-circuit, and 2-pole configurations\u003c\/li\u003e\n\u003cli\u003eStandard, AFCI, GFCI, and dual function AF GF protection levels\u003c\/li\u003e\n\u003cli\u003ePigtail or plug-on neutral connection on AFCI and dual function levels\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eThermal magnetic trip on standard units; electronic trip on protection units\u003c\/li\u003e\n\u003cli\u003ePlug-on bus connection with no mounting hardware\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfigurations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, tandem two-circuit, 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V standard, tandem, and 2-pole units; AFCI, GFCI, and dual function units rated 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic (standard, tandem, 2-pole); electronic (AFCI, GFCI, dual function)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, AFCI, GFCI, dual function AF\/GF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePigtail or plug-on neutral on AFCI and dual function levels, per variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne breaker per unit, configuration and protection level per selected variant\u003c\/li\u003e\n\u003cli\u003ePigtail versions include their factory neutral pigtail; plug-on neutral versions include the neutral foot hardware\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eAFCI, GFCI, and dual function locations follow the NEC edition adopted in your jurisdiction\u003c\/li\u003e\n\u003cli\u003eTandem units go only in slots the panel label permits\u003c\/li\u003e\n\u003cli\u003ePlug-on neutral versions require a load center with a plug-on neutral bus; pigtail versions land on the neutral bar\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePigtail or plug-on neutral, which do I pick?\u003c\/strong\u003e\u003cbr\u003eMatch the panel. Load centers with a plug-on neutral bus take the plug-on neutral versions and skip the pigtail entirely; any other compatible 1 in. plug-on panel takes the pigtail versions. The trade desk checks this against your panel at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I use the tandem unit anywhere in the panel?\u003c\/strong\u003e\u003cbr\u003eNo. Tandem units belong only in slots the panel label lists as tandem-permitted. The panel schedule is checked at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich protection level do I need?\u003c\/strong\u003e\u003cbr\u003eStandard units cover general branch circuits. The NEC calls for AFCI protection in most dwelling living areas, GFCI protection in wet and damp locations, and dual function units where one circuit needs both. Your electrician and the trade desk confirm the schedule at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-CTDL-submittal.pdf?v=1783373121\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-CTDL-dimensional.pdf?v=1783373121\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-CTDL-install-warranty.pdf?v=1783373121\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Single-Pole \/ Standard","offer_id":48943861563648,"sku":"LA-LGT-BRK-A20-CTDL-STD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Tandem Two Circuit \/ Standard","offer_id":48943861596416,"sku":"LA-LGT-BRK-A20-CTDL-TDM","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2-Pole \/ Standard","offer_id":48943861629184,"sku":"LA-LGT-BRK-A20-CTDL-2P","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ AFCI","offer_id":48943861661952,"sku":"LA-LGT-BRK-A20-CTDL-AFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ AFCI Plug-On Neutral","offer_id":48943861694720,"sku":"LA-LGT-BRK-A20-CTDL-PAF","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ GFCI","offer_id":48943861727488,"sku":"LA-LGT-BRK-A20-CTDL-GFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ Dual Function AF GF","offer_id":48943861760256,"sku":"LA-LGT-BRK-A20-CTDL-DFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Single-Pole \/ Dual Function AF GF Plug-On Neutral","offer_id":48943861793024,"sku":"LA-LGT-BRK-A20-CTDL-PDF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_16db6030-ba58-4bfe-ad7f-f80bfa216b96.png?v=1783372883","url":"https:\/\/ironcinder.com\/products\/light-archon-citadel-20a-circuit-breaker-platform","provider":"IronCinder","version":"1.0","type":"link"}