{"product_id":"light-archon-dryerloop-10-3-copper-nm-b-cable-with-ground","title":"Light Archon DryerLoop 10\/3 Copper NM-B Cable with Ground","description":"\u003cp\u003eLight Archon DryerLoop 10\/3 copper NM-B cable runs the 30A appliance circuits: electric dryers, wall ovens, and other four-wire 120\/240V loads inside dry framing. Three solid 10 AWG copper conductors and a bare ground ride under a pink 600V jacket that flags the construction on sight.\u003c\/p\u003e\u003cp\u003eThe pink coil color is the trade cue for this 10\/3 construction, so mixed-gauge staging areas stay sorted. A slick jacket construction cuts pulling force through drilled studs, and production print carries standard size and type text only. NM-B ampacity rides the NEC 60C column, which puts 10 AWG at 30A for the dryer and oven circuits this cable is built for. The desk confirms run counts and breaker matching at quote review.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e10\/3 with ground: three solid copper conductors plus bare copper equipment ground\u003c\/li\u003e\n\u003cli\u003eBuilt for 30A four-wire appliance circuits: dryers, wall ovens, 120\/240V loads\u003c\/li\u003e\n\u003cli\u003eRated 600V; ampacity per the NEC 60C column that governs NM-B\u003c\/li\u003e\n\u003cli\u003ePink jacket flags the 10\/3 construction at a glance\u003c\/li\u003e\n\u003cli\u003eEasy-pull jacket construction for fast rough-in per the published listing\u003c\/li\u003e\n\u003cli\u003eUL listed per the published listing\u003c\/li\u003e\n\u003cli\u003eFactory runs from 15 ft to 1000 ft to match takeoff counts\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply: no public prices, one submittal covers the whole job\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/3 with ground, NM-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 AWG solid annealed copper, three circuit conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, pink, standard size and type print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V, 194F rated with 140F ampacity limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30A per the NEC 60C column for 10 AWG NM-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry interior locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15, 25, 50, 100, 250, and 1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDryers, wall ovens, 30A four-wire appliance runs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first factory-sealed runs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eContinuous factory run in the selected length\u003c\/li\u003e\n\u003cli\u003eFactory-sealed coil wrap or spool per length\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePair 10 AWG copper NM-B with 30A overcurrent protection per NEC and the appliance nameplate.\u003c\/li\u003e\n\u003cli\u003eFour-wire appliance circuits land separate neutral and ground at the receptacle or junction per NEC.\u003c\/li\u003e\n\u003cli\u003eMay run in air voids of masonry block or tile walls where not subject to excessive moisture per the published listing.\u003c\/li\u003e\n\u003cli\u003eSupport and secure at NEC spacing intervals; protect from nail strikes with steel plates where required.\u003c\/li\u003e\n\u003cli\u003eFinal circuit counts, run lengths, and breaker matchups are confirmed at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat circuits is this gauge rated for?\u003c\/strong\u003e\u003cbr\u003e10 AWG copper NM-B rides the NEC 60C column at 30A, which matches electric dryer and wall oven circuits and other 30A four-wire 120\/240V loads.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhy is the coil pink?\u003c\/strong\u003e\u003cbr\u003ePink is the production color cue for this 10\/3 construction, keeping it distinct from 10\/2 and other gauges on a staged job. The jacket print carries the definitive size and type text.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat lengths can I quote?\u003c\/strong\u003e\u003cbr\u003eFactory runs of 15, 25, 50, 100, 250, and 1000 ft. Mixed lengths on one quote list are fine.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this cable run outdoors or underground?\u003c\/strong\u003e\u003cbr\u003eNo. NM-B is listed for dry interior locations. For wet locations or burial, quote THHN conductors in conduit or a UF class cable at review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-WR-G103-DRYL-submittal.pdf?v=1783373437\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-WR-G103-DRYL-dimensional.pdf?v=1783373437\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-WR-G103-DRYL-install-warranty.pdf?v=1783373437\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"15 ft","offer_id":48943874277632,"sku":"LA-LGT-WR-G103-DRYL-15FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"25 ft","offer_id":48943874310400,"sku":"LA-LGT-WR-G103-DRYL-25FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"50 ft","offer_id":48943874343168,"sku":"LA-LGT-WR-G103-DRYL-50FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"100 ft","offer_id":48943874375936,"sku":"LA-LGT-WR-G103-DRYL-100FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"250 ft","offer_id":48943874408704,"sku":"LA-LGT-WR-G103-DRYL-250FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft","offer_id":48943874441472,"sku":"LA-LGT-WR-G103-DRYL-1KFT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_99664896-8de5-4b5b-b866-dacd63cf3bfb.png?v=1783373069","url":"https:\/\/ironcinder.com\/products\/light-archon-dryerloop-10-3-copper-nm-b-cable-with-ground","provider":"IronCinder","version":"1.0","type":"link"}