{"product_id":"light-archon-palisade-15a-single-pole-circuit-breaker","title":"Light Archon Palisade 15A Single-Pole Circuit Breaker","description":"\u003cp\u003eLight Archon Palisade breakers cover the 15 A single-pole slot in the industry-standard 1 in. plug-on format. Two protection levels share the platform: a standard thermal magnetic unit for general branch circuits and a dual function AF\/GF unit that puts arc fault and ground fault protection in one device with a single point of reset. Every unit is quote-first: add it to your quote list and the trade desk confirms panel fit before release.\u003c\/p\u003e\u003cp\u003eThe standard unit is a straightforward thermal magnetic breaker rated 120\/240V. The dual function unit protects the entire circuit, including home runs, against both arc faults and ground faults, and its integral LED reads out trip codes that separate thermal overload from fault trips, cutting troubleshooting time. A short-body case and reduced pigtail clutter keep gutter space open for conductor work. Interrupt rating is 10 kA across the line, and both units land on the bus with a plug-on connection.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15 A single-pole platform in the 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003eStandard and dual function AF GF protection levels\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eDual function unit combines AFCI and GFCI protection with one reset point\u003c\/li\u003e\n\u003cli\u003eLED diagnostic trip codes on the dual function unit speed troubleshooting\u003c\/li\u003e\n\u003cli\u003eShort-body case maximizes gutter space for conductor installation\u003c\/li\u003e\n\u003cli\u003ePlug-on bus connection with no mounting hardware\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, 1 in. format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V standard unit; dual function AF\/GF unit rated 120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic standard unit; electronic with LED trip codes on dual function unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, dual function AF\/GF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNeutral Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual function unit ships with a factory neutral pigtail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne breaker per unit, protection level per selected variant\u003c\/li\u003e\n\u003cli\u003eDual function unit includes its factory neutral pigtail\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eTorque terminations to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eDual function AF\/GF protection locations follow the NEC edition adopted in your jurisdiction\u003c\/li\u003e\n\u003cli\u003eLand the dual function unit pigtail on the panel neutral bar\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat does the dual function unit protect against?\u003c\/strong\u003e\u003cbr\u003eBoth arc faults and ground faults on the same circuit, including the home run, with a single device and one reset point. The integral LED flashes trip codes so your electrician can tell a thermal overload from a fault trip.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhen is dual function protection required?\u003c\/strong\u003e\u003cbr\u003eThe NEC calls for AFCI protection in most dwelling living areas and GFCI protection in wet and damp locations; a dual function unit covers circuits where the plan calls for both. Your electrician and the trade desk confirm the schedule at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. Every product shows a zero price on the site; your quote list is priced by the trade desk with panel fit checked line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A15-PLSD-submittal.pdf?v=1783373117\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A15-PLSD-dimensional.pdf?v=1783373117\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A15-PLSD-install-warranty.pdf?v=1783373117\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Standard","offer_id":48943861268736,"sku":"LA-LGT-BRK-A15-PLSD-STD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Dual Function AF GF","offer_id":48943861301504,"sku":"LA-LGT-BRK-A15-PLSD-DFC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_4f6f346f-fdbb-4bdf-a875-ef6c3d0c1856.png?v=1783372879","url":"https:\/\/ironcinder.com\/products\/light-archon-palisade-15a-single-pole-circuit-breaker","provider":"IronCinder","version":"1.0","type":"link"}