{"product_id":"light-archon-powerdock-outdoor-power-outlet-panels","title":"Light Archon PowerDock Outdoor Power Outlet Panels","description":"\u003cp\u003eLight Archon PowerDock panels put finished outdoor power where the loads live: RV pads, generator hookups, patios, workshops, and EV-adjacent parking. Each format is a pre-wired, lockable steel box with the receptacle configuration built in, so the install is feed, land, and close.\u003c\/p\u003e\u003cp\u003eThe dual-GFCI format carries two 20A weather-resistant, tamper-resistant duplexes with independent ground-fault protection on a 125V feed. The 30A format pairs an L14-30R twist-lock with a 15A switch on a 125\/250V feed, and the 50A format carries the 14-50R range-pattern receptacle RV services use. All three ride in NEMA 3R steel housings with corrosion-resistant powder coat, lockable rainproof covers, and 1\/2 to 1 in. conduit knockouts, ETL listed per the published listing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThree pre-wired formats: dual 20A GFCI, 30A L14-30R with switch, 50A 14-50R\u003c\/li\u003e\n\u003cli\u003eNEMA 3R steel housings with lockable rainproof covers\u003c\/li\u003e\n\u003cli\u003eWeather-resistant, tamper-resistant GFCI duplexes on the 20A format\u003c\/li\u003e\n\u003cli\u003e125\/250V twist-lock and RV-pattern formats for generator and pad service\u003c\/li\u003e\n\u003cli\u003eCorrosion-resistant powder coat over steel\u003c\/li\u003e\n\u003cli\u003eEnlarged wiring chamber with grounding terminals per the published listing\u003c\/li\u003e\n\u003cli\u003eMultiple 1\/2 to 1 in. conduit knockouts\u003c\/li\u003e\n\u003cli\u003eETL listed per the published listing; quote-first trade supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormats\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 20A GFCI; 30A L14-30R with 15A switch; 50A 14-50R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel, corrosion-resistant powder coat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R weatherproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125V GFCI format; 125\/250V on 30A and 50A formats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLockable rainproof covers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKnockouts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple, 1\/2 to 1 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEnlarged chamber, grounding terminals, copper conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eETL listed per the published listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRV pads, generators, patios, site power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWet locations, outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first; breaker and feeder sizing confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePre-wired outlet panel in the selected format\u003c\/li\u003e\n\u003cli\u003eLockable rainproof cover assembly\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFeed each format from an upstream breaker matched to its rating per NEC; the desk confirms breaker and conductor sizing at quote review.\u003c\/li\u003e\n\u003cli\u003eThe 50A 14-50R format serves RV pads and range-pattern loads; verify the connected equipment pattern before rough-in.\u003c\/li\u003e\n\u003cli\u003eSurface mount to structure or post with corrosion-resistant fasteners; keep cover swing clear.\u003c\/li\u003e\n\u003cli\u003eLand conduit through the 1\/2 to 1 in. knockouts with raintight fittings.\u003c\/li\u003e\n\u003cli\u003eCopper conductors land on the grounding and line terminals per the published listing; torque to spec.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhich format for an RV pad?\u003c\/strong\u003e\u003cbr\u003eThe 50A 14-50R format covers larger coaches; the 30A L14-30R twist-lock format suits generator interlocks and 30A equipment. Many pads quote both plus the GFCI format for convenience power.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAre the GFCI outlets protected individually?\u003c\/strong\u003e\u003cbr\u003eYes. The dual-GFCI format carries two 20A weather-resistant duplexes with independent ground-fault protection, so a trip on one leaves the other live.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo these need a separate weatherproof cover?\u003c\/strong\u003e\u003cbr\u003eNo. The lockable rainproof cover is part of the panel; the NEMA 3R housing and cover arrive as one assembly.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat feeds do they take?\u003c\/strong\u003e\u003cbr\u003eThe GFCI format lands a 125V branch circuit; the 30A and 50A formats land 125\/250V feeds. Breaker and conductor sizing is confirmed at quote review.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BX-WP20-PWDK-submittal.pdf?v=1783373169\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BX-WP20-PWDK-dimensional.pdf?v=1783373170\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BX-WP20-PWDK-install-warranty.pdf?v=1783373169\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Dual 20A GFCI Receptacles","offer_id":48943864021248,"sku":"LA-LGT-BX-WP20-PWDK-20GFCI","price":0.0,"currency_code":"USD","in_stock":true},{"title":"30A L14-30R with 15A Switch","offer_id":48943864054016,"sku":"LA-LGT-BX-WP20-PWDK-30LOCK","price":0.0,"currency_code":"USD","in_stock":true},{"title":"50A 14-50R Receptacle","offer_id":48943864086784,"sku":"LA-LGT-BX-WP20-PWDK-50RV","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_542525e1-566a-428d-a8e4-4f73f01ccc0b.png?v=1783372910","url":"https:\/\/ironcinder.com\/products\/light-archon-powerdock-outdoor-power-outlet-panels","provider":"IronCinder","version":"1.0","type":"link"}