{"product_id":"light-archon-riseworks-steel-covers-4-in-square-boxes","title":"Light Archon RiseWorks Steel Covers for 4 in. Square Boxes","description":"\u003cp\u003eLight Archon RiseWorks covers finish 4 in. square boxes for device work: raised covers set switches and receptacles flush with drywall, GFCI formats frame protected devices, and flat and surface formats close junction and exposed-work boxes.\u003c\/p\u003e\u003cp\u003eStamped from galvanized steel, the raised formats lift the device plane 1\/2 in. or 5\/8 in. so devices land flush on finished walls, the standard method for commercial rough-in on square boxes. Duplex, single-device, and GFCI openings cover the common device mix, the surface double-duplex format serves exposed work, and the flat cover with knockout closes a box while passing a raceway. UL and CSA listed per the published listing.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRaised covers in 1\/2 in. and 5\/8 in. depths set devices flush with drywall\u003c\/li\u003e\n\u003cli\u003eDuplex, single-device, and GFCI openings cover the standard device mix\u003c\/li\u003e\n\u003cli\u003eSurface double-duplex format for exposed-work receptacle points\u003c\/li\u003e\n\u003cli\u003eFlat cover with 1\/2 in. knockout closes boxes and passes raceway\u003c\/li\u003e\n\u003cli\u003eGalvanized steel stock resists corrosion in dry interiors\u003c\/li\u003e\n\u003cli\u003eUL and CSA listed per the published listing\u003c\/li\u003e\n\u003cli\u003eFits 4 in. square boxes on standard screw spacing\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply; case quantities quoted on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFormats\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRaised device, duplex, GFCI, flat with knockout, surface double duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRaised depths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2 in. and 5\/8 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 in. square boxes, standard screw spacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOpenings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle device, two device, duplex, GFCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKnockout\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2 in. on the flat closure format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL and CSA listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry interior locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBase size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 in. square face\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first; case quantities quoted on request\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eCover in the selected format with mounting screw holes on standard spacing\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMatch the raised depth to the finished wall thickness so devices land flush.\u003c\/li\u003e\n\u003cli\u003eRaised covers count toward box fill credits per NEC; the desk checks fill on device-heavy landings.\u003c\/li\u003e\n\u003cli\u003eUse the GFCI formats for devices with test and reset faces; standard duplex openings do not fit them.\u003c\/li\u003e\n\u003cli\u003eSurface formats suit exposed work where the box face stays accessible.\u003c\/li\u003e\n\u003cli\u003eFormat counts and case quantities are confirmed at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhich raised depth do I quote?\u003c\/strong\u003e\u003cbr\u003eMatch the drywall: 1\/2 in. covers standard single-layer walls, 5\/8 in. covers thicker board. The device face lands flush when the rise equals the wall finish.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDo these fit the SteelForm square boxes?\u003c\/strong\u003e\u003cbr\u003eYes. RiseWorks covers land on 4 in. square boxes on standard screw spacing, including the Light Archon SteelForm line quoted alongside them.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat closes an unused junction box?\u003c\/strong\u003e\u003cbr\u003eThe flat cover, with a 1\/2 in. knockout available when a raceway needs to pass through the closure.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAre GFCI covers different from duplex covers?\u003c\/strong\u003e\u003cbr\u003eYes. GFCI formats frame the rectangular device face with test and reset buttons; duplex formats frame two round outlet faces. Quote by the device schedule.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BX-C4MR-RISE-submittal.pdf?v=1783373159\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BX-C4MR-RISE-dimensional.pdf?v=1783373159\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BX-C4MR-RISE-install-warranty.pdf?v=1783373160\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Single Duplex Cover, 1\/2 in. Raised","offer_id":48943863464192,"sku":"LA-LGT-BX-C4MR-RISE-1DUP12","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1-Gang Raised Device Cover","offer_id":48943863496960,"sku":"LA-LGT-BX-C4MR-RISE-1GDEV","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Flat Cover with 1\/2 in. Knockout","offer_id":48943863529728,"sku":"LA-LGT-BX-C4MR-RISE-FLATKO","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Surface Cover, Double Duplex","offer_id":48943863562496,"sku":"LA-LGT-BX-C4MR-RISE-SDDUP","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1-Gang Raised Device Cover, 5\/8 in.","offer_id":48943863595264,"sku":"LA-LGT-BX-C4MR-RISE-1GDEV58","price":0.0,"currency_code":"USD","in_stock":true},{"title":"GFCI Cover, Single Device","offer_id":48943863628032,"sku":"LA-LGT-BX-C4MR-RISE-GFCI1","price":0.0,"currency_code":"USD","in_stock":true},{"title":"GFCI Cover, Two Devices","offer_id":48943863660800,"sku":"LA-LGT-BX-C4MR-RISE-GFCI2","price":0.0,"currency_code":"USD","in_stock":true},{"title":"2-Device Raised Cover, 5\/8 in.","offer_id":48943863693568,"sku":"LA-LGT-BX-C4MR-RISE-2GDEV58","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_efe9c6d3-b80b-402a-b7a1-65dcc20368f8.png?v=1783372904","url":"https:\/\/ironcinder.com\/products\/light-archon-riseworks-steel-covers-4-in-square-boxes","provider":"IronCinder","version":"1.0","type":"link"}