{"product_id":"light-archon-switchloop-14-3-copper-nm-b-cable-with-ground","title":"Light Archon SwitchLoop 14\/3 Copper NM-B Cable with Ground","description":"\u003cp\u003eLight Archon SwitchLoop 14\/3 copper NM-B cable is the three-conductor run for 3-way and 4-way switching, split-wired receptacles, and fan-and-light circuits that need a separate switched leg. Each run is a continuous factory length with three 14 AWG solid copper conductors, a bare copper ground, and a light blue 600V jacket.\u003c\/p\u003e\u003cp\u003eThe light blue jacket is the trade color cue for the 14\/3 construction, keeping travelers and switched legs obvious in a packed stud bay. A slick outer surface cuts pulling force through drilled framing, the jacket strips clean, and production print carries standard size and type text only. The listed maximum is 15A for 14 AWG, matching 15A overcurrent protection on lighting circuits. The desk confirms run counts and switching layouts at quote review.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e14\/3 with ground: three solid copper conductors plus bare copper equipment ground\u003c\/li\u003e\n\u003cli\u003ePurpose-built for 3-way and 4-way switching and split-wired circuits\u003c\/li\u003e\n\u003cli\u003eRated 600V with a light blue jacket that flags the construction at a glance\u003c\/li\u003e\n\u003cli\u003e15A listed maximum ampacity for 14 AWG copper\u003c\/li\u003e\n\u003cli\u003eEasy-strip, easy-pull jacket keeps rough-in moving\u003c\/li\u003e\n\u003cli\u003eUL listed per the published listing\u003c\/li\u003e\n\u003cli\u003eFactory runs from 15 ft to 1000 ft to match takeoff counts\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply: no public prices, one submittal covers the whole job\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConstruction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\/3 with ground, NM-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 AWG solid annealed copper, three circuit conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEquipment ground\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBare copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC, light blue, standard size and type print\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmpacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15A listed maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry interior locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLengths\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15, 25, 50, 100, 250, and 1000 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical circuits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3-way and 4-way switching, fan-and-light legs, split receptacles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuote-first factory-sealed runs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eContinuous factory run in the selected length\u003c\/li\u003e\n\u003cli\u003eFactory-sealed coil wrap or spool per length\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePair 14 AWG copper with 15A overcurrent protection per NEC.\u003c\/li\u003e\n\u003cli\u003eUse the red conductor as the traveler or switched leg and re-identify per local practice.\u003c\/li\u003e\n\u003cli\u003eCount conductors, clamps, and devices toward box fill per NEC; three-conductor runs fill boxes faster than two-conductor runs.\u003c\/li\u003e\n\u003cli\u003eNM-B is limited to dry interior locations; support and secure at NEC spacing intervals.\u003c\/li\u003e\n\u003cli\u003eFinal circuit counts, run lengths, and switching layouts are confirmed at quote review.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBacked by the Light Archon trade supply program; warranty terms are confirmed at quote review.\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and takeoff review support are available from our electrical supply desk.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhen do I need 14\/3 instead of 14\/2?\u003c\/strong\u003e\u003cbr\u003eAny time a circuit needs two hot legs in one cable: 3-way and 4-way switch runs, separate fan and light control, split-wired receptacles, or shared-neutral multiwire circuits installed per NEC.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat lengths can I quote?\u003c\/strong\u003e\u003cbr\u003eFactory runs of 15, 25, 50, 100, 250, and 1000 ft. Mixed lengths on one quote list are fine.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this cable run outdoors or underground?\u003c\/strong\u003e\u003cbr\u003eNo. NM-B is listed for dry interior locations. For wet locations or burial, quote THHN conductors in conduit or a UF class cable at review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs the jacket print neutral?\u003c\/strong\u003e\u003cbr\u003eYes. Production jacket print carries standard size and type text such as 14\/3 W\/G NM-B 600V, with no retail brand marks.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-WR-G143-SWLP-submittal.pdf?v=1783373447\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-WR-G143-SWLP-dimensional.pdf?v=1783373447\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-WR-G143-SWLP-install-warranty.pdf?v=1783373447\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"15 ft","offer_id":48943875064064,"sku":"LA-LGT-WR-G143-SWLP-15FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"25 ft","offer_id":48943875096832,"sku":"LA-LGT-WR-G143-SWLP-25FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"50 ft","offer_id":48943875129600,"sku":"LA-LGT-WR-G143-SWLP-50FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"100 ft","offer_id":48943875162368,"sku":"LA-LGT-WR-G143-SWLP-100FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"250 ft","offer_id":48943875195136,"sku":"LA-LGT-WR-G143-SWLP-250FT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"1000 ft","offer_id":48943875227904,"sku":"LA-LGT-WR-G143-SWLP-1KFT","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_74906be3-d8e0-4c82-bb6d-d29bbf620db8.png?v=1783373074","url":"https:\/\/ironcinder.com\/products\/light-archon-switchloop-14-3-copper-nm-b-cable-with-ground","provider":"IronCinder","version":"1.0","type":"link"}