{"product_id":"light-archon-talos-20a-single-pole-circuit-breaker","title":"Light Archon Talos 20A Single-Pole Circuit Breaker","description":"\u003cp\u003eLight Archon Talos breakers carry the 20 A single-pole branch slot in a 1 in. plug-on format with four protection levels: standard thermal magnetic, ground fault with built-in self-test, arc fault, and a dual function unit that combines both. The platform is quote-first, and the trade desk verifies panel fit on every line before release.\u003c\/p\u003e\u003cp\u003eTin-plated copper stabs make a corrosion-resistant bus connection, and the heat-resistant thermoset case holds calibration over the service life; the calibration screw is cemented to prevent shift. Handles trip to the center position so a fault reads at a glance. The ground fault unit runs an automatic self-test and trips if it loses the ability to protect the circuit, per the self-test requirement in current UL practice.\u003c\/p\u003e\u003ch3\u003eHighlights\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e20 A single-pole platform, 1 in. plug-on format\u003c\/li\u003e\n\u003cli\u003eStandard, GFCI self-test, AFCI, and dual function AF\/GF levels\u003c\/li\u003e\n\u003cli\u003e10 kA interrupt rating\u003c\/li\u003e\n\u003cli\u003eTin-plated copper stabs for a corrosion-resistant connection\u003c\/li\u003e\n\u003cli\u003eHeat-resistant thermoset case with cemented calibration screw\u003c\/li\u003e\n\u003cli\u003eTrips to center position for clear fault indication\u003c\/li\u003e\n\u003cli\u003eUL Listed, ANSI certified, CSA listed\u003c\/li\u003e\n\u003cli\u003eQuote-first trade supply with panel fit verified before release\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecification Table\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-pole, 1 in. format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTrip Unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-on bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard, GFCI self-test, AFCI, dual function AF\/GF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStabs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTin-plated copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeat-resistant thermoset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003efits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLocation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDry indoor panel interiors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Listed, ANSI certified, CSA listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLight Archon limited trade warranty, confirmed at quote review\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eIncluded Components\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOne breaker per unit, protection level per selected variant\u003c\/li\u003e\n\u003cli\u003eSelf-test electronics built into the GFCI and dual function units\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInstalled by a licensed electrician; breaker ampacity must match conductor rating\u003c\/li\u003e\n\u003cli\u003eDe-energize the panel and verify with a meter before any work\u003c\/li\u003e\n\u003cli\u003eBox type terminals; torque to the values on the breaker label\u003c\/li\u003e\n\u003cli\u003eGFCI and AFCI protection locations follow the NEC edition adopted in your jurisdiction\u003c\/li\u003e\n\u003cli\u003ePanel fit is verified at quote review against your load center schedule\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWarranty and Support\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCovered by the Light Archon limited trade warranty; term confirmed at quote review\u003c\/li\u003e\n\u003cli\u003eSubmittal sheets and dimensional PDFs available for every configuration\u003c\/li\u003e\n\u003cli\u003eSupport through the Light Archon trade desk\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat panels does this fit?\u003c\/strong\u003e\u003cbr\u003eIt fits Light Archon LC series and industry-standard 1 in. bolt\/plug-on load centers - verify panel compatibility at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes the ground fault unit self-test?\u003c\/strong\u003e\u003cbr\u003eYes. The GFCI unit runs a built-in self-test and trips if it loses the ability to protect, so a failed device does not sit silent in the panel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhich protection level do I need?\u003c\/strong\u003e\u003cbr\u003eStandard covers most branch circuits; the NEC calls for AFCI in most dwelling living areas and GFCI in wet and damp locations. The dual function unit satisfies both on one circuit. Your electrician confirms the schedule at quote review.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow is this sold?\u003c\/strong\u003e\u003cbr\u003eQuote-first. The site shows a zero price; the trade desk prices your quote list and checks panel fit line by line.\u003c\/p\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-TALOS-submittal.pdf?v=1783306771\" target=\"_blank\" rel=\"noopener\"\u003eProduct Submittal Summary (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-TALOS-dimensional.pdf?v=1783306771\" target=\"_blank\" rel=\"noopener\"\u003eDimensional \u0026amp; Fit Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/LA-LGT-BRK-A20-TALOS-install-warranty.pdf?v=1783306771\" target=\"_blank\" rel=\"noopener\"\u003eInstallation \u0026amp; Warranty Reference (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Light Archon","offers":[{"title":"Standard","offer_id":48934490702080,"sku":"LA-LGT-BRK-A20-TALOS-STD","price":0.0,"currency_code":"USD","in_stock":true},{"title":"GFCI Self Test","offer_id":48934490734848,"sku":"LA-LGT-BRK-A20-TALOS-GFT","price":0.0,"currency_code":"USD","in_stock":true},{"title":"AFCI","offer_id":48934490767616,"sku":"LA-LGT-BRK-A20-TALOS-AFC","price":0.0,"currency_code":"USD","in_stock":true},{"title":"Dual Function AF GF","offer_id":48934490800384,"sku":"LA-LGT-BRK-A20-TALOS-DFC","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0829\/7490\/0480\/files\/01-hero_9ae5cf08-35ab-43bf-8b6e-1b8d08b6dc15.png?v=1783306379","url":"https:\/\/ironcinder.com\/products\/light-archon-talos-20a-single-pole-circuit-breaker","provider":"IronCinder","version":"1.0","type":"link"}