Air Dominion CHV Pro VRF Fresh Air Processor Indoor Unit Platform

SKU: AD-HVAC-VRF-IDU-FRESH-AIR

Reviewed pricing, lead time, freight, and final configuration are confirmed during quote review before order release.

Air Dominion CHV Pro VRF Fresh Air Processor Indoor Unit Platform covers the fresh air processor family of the CHV Pro VRF line: dedicated outdoor-air processing unit conditioning ventilation air on the VRF circuit. Factory capacity steps span 14.0-56.0 kW (approximately 47,800 to 191,100 BTU/h). This is a quote-first engineering platform page, not an off-the-shelf item: every CHV Pro system is configured per project during quote review.

Highlights

  • Fresh Air Processor indoor family for CHV Pro VRF systems
  • Capacity steps across 14.0-56.0 kW (approximately 47,800-191,100 BTU/h)
  • Mixes freely with other CHV Pro indoor types on one refrigerant system
  • Selected, sized, and zoned per project during quote review
  • Part of systems serving up to 100 indoor units

Specification Table

Indoor type Fresh Air Processor
Capacity range 14.0-56.0 kW (47,800-191,100 BTU/h approx.)
Platform CHV Pro full DC inverter VRF
Configuration Per project during quote review
Refrigerant Confirmed during quote review

Included Equipment

  • Scope is configured per project: indoor units of this family at the capacities scheduled in the quote packet

Installation Notes

  • Unit count, capacity steps, placement, controls, and condensate design are defined in the project quote packet.
  • Requires a CHV Pro VRF outdoor platform sized during quote review.
  • Design, installation, and commissioning by qualified VRF-certified professionals.
  • Images are representative of product class and included accessory configuration. Final model, electrical requirements, and included components are confirmed during quote review.

Warranty and Support

  • Prepared for Air Dominion quote review. Final equipment schedule, warranty coverage, and engineering documents are confirmed before release.

Frequently Asked Questions

Can I order this indoor unit by itself?
Indoor units are quoted as part of a CHV Pro VRF system. Add the platform to your quote list and the schedule is engineered during quote review.

What does the quote cover?
Project load calculation review and outdoor-module tier selection; Outdoor module combination plan (up to 3 modules, to 96 HP); Indoor unit mix and count (up to 100 indoor units per system, configuration-dependent); Electrical service selection: 208-230V/3N/60Hz or 380-415V/3N/50-60Hz; Refrigerant piping design, controls and zoning scheme, and commissioning documentation.

What sizes exist in this family?
Factory steps span 14.0-56.0 kW - approximately 47,800 to 191,100 BTU/h. Exact steps are scheduled during quote review.

Can different indoor types mix on one system?
Yes. CHV Pro systems mix cassette, ducted, wall, floor-ceiling, and fresh-air units on one refrigerant network, subject to engineering limits.

Documents

  • Type VRF Platform
  • SKU AD-HVAC-VRF-IDU-FRESH-AIR

Download the available product documents below. If a document is not linked yet, use the SKU during quote review.

Project pricing, lead time, freight routing, and final configuration are confirmed during quote review before order release.

Support and request quote workflows stay available throughout specification and order planning.