Light Archon Crestline 15A Duplex Outlet 10-Pack
Reviewed pricing, lead time, freight, and final configuration are confirmed during quote review before order release.
Light Archon Crestline duplex outlets are the rough-in staple, sold in contractor 10-packs so full floors quote in one line. Pick the classic duplex face or the designer rectangular face, standard or tamper resistant, all 15 A, 125V, NEMA 5-15R in White.
Tamper resistant versions carry the TR shutter mechanism the NEC requires in most dwelling locations: the shutters stay closed unless both prongs of a plug insert at the same time, locking out keys and hairpins. The shallow body leaves room for conductors in the box, and heavy-duty ultrasonic construction holds up on the job. Devices back wire and side wire with screw terminals for fast production work.
Highlights
- 15 A, 125V duplex receptacle, NEMA 5-15R
- Contractor 10-pack; one line covers a full floor of rough-in
- Classic duplex or designer rectangular face
- Standard and tamper resistant versions
- TR shutter mechanism meets NEC receptacle requirements for dwellings
- Shallow body for easier box fill
- Back wire and side wire with screw terminals
- UL Listed and CSA Listed
Specification Table
| Current Rating | 15 A |
| Input Rating | 125V |
| NEMA Configuration | NEMA 5-15R |
| Faces | Classic duplex and designer rectangular |
| Versions | Standard and tamper resistant (TR shutters) |
| Pack Count | 10 devices per pack |
| Material | Polycarbonate |
| Terminals | Back and side wire, screw terminals |
| Color | White |
| Wall Plate | Not included; 1-gang plates quoted separately |
| Certifications | UL Listed, CSA Listed |
| Warranty | Light Archon limited trade warranty, confirmed at quote review |
Included Components
- Ten devices per pack in the selected face and version
- Mounting screws
- Wall plates not included; 1-gang plates quoted separately
Installation Notes
- Installed by a licensed electrician in standard single-gang boxes; verify box fill
- Tamper resistant receptacles are required by the NEC in most dwelling locations
- Do not install on circuits above the device rating
- Classic faces take standard duplex plates; designer faces take designer opening plates
Warranty and Support
- Covered by the Light Archon limited trade warranty; term confirmed at quote review
- Submittal sheets and dimensional PDFs available for every configuration
- Support through the Light Archon trade desk
Frequently Asked Questions
What box does it need?
A standard single-gang wall box per device. Have the installer verify box fill for the conductors present.
Do the two faces need different plates?
Yes. The classic duplex face takes a standard duplex wall plate; the designer rectangular face takes a designer opening plate. Plates are quoted separately.
Do I need the tamper resistant version?
The NEC requires TR receptacles in most dwelling locations. Pick the TR variant unless your inspector confirms the location is exempt.
How are the packs quoted?
Each variant is a 10-pack line item. Add the counts you need to your quote list and the trade desk prices the job as one release.
Documents
- Type Outlet
- SKU LA-LGT-DV-D15-CREST-CTR
- Catalog Reference Installation & Warranty Reference (PDF)
- Spec PDF Open product spec summary
- Submittal PDF Open submittal reference
Download the available product documents below. If a document is not linked yet, use the SKU during quote review.
Project pricing, lead time, freight routing, and final configuration are confirmed during quote review before order release.
Support and request quote workflows stay available throughout specification and order planning.