Light Archon IronPath Rigid Metal Conduit, 2 in. x 10 ft.

SKU: LA-LGT-CN-R2-IRNP

Reviewed pricing, lead time, freight, and final configuration are confirmed during quote review before order release.

Light Archon IronPath is heavy-wall rigid metal conduit for the runs that take abuse: service masts, exposed yard and dock runs, mechanical rooms, and anywhere the raceway itself is the armor. Sticks quote in the 2 in. trade size at 10 ft.

The galvanized heavy-wall steel puts the maximum standard raceway protection around feeders and branch conductors, and it serves as an equipment grounding conductor when assembled with listed fittings per NEC. Threaded joints are the standard method for the type. Where the takeoff needs elbows, couplings, nipples, or other trade sizes, the desk quotes them with the sticks at review.

Highlights

  • Heavy-wall galvanized steel raceway for maximum physical protection
  • 2 in. trade size in 10 ft sticks
  • Serves as an equipment grounding conductor with listed fittings per NEC
  • Suits service masts, exposed runs, and damage-prone routes
  • Interior and exterior use installed per NEC
  • Elbows, couplings, and other trade sizes quoted on request
  • Quote-first trade supply with submittal support

Specification Table

Type Rigid metal conduit, heavy wall
Material Galvanized steel
Trade size 2 in.
Stick length 10 ft
Joints Threaded, standard for the type
Ground path Equipment grounding conductor with listed fittings per NEC
Use Exposed, concealed, interior, exterior per NEC
Protection Heaviest standard raceway wall class
Listings Confirmed at quote review
Supply model Quote-first; bundle counts and fittings quoted together

Included Components

  • Conduit sticks only; elbows, couplings, straps, and fittings quoted separately

Installation Notes

  • Cut, thread, and ream field joints per standard rigid conduit practice; use listed fittings.
  • Support and secure per NEC spacing for the trade size.
  • Raintight or wet-location fittings on exterior runs per NEC.
  • Bond the raceway into the equipment grounding path per NEC.
  • Fitting types, bend counts, and bundle quantities are confirmed at quote review.

Warranty and Support

  • Backed by the Light Archon trade supply program; warranty terms are confirmed at quote review.
  • Submittal sheets and takeoff review support are available from our electrical supply desk.

Frequently Asked Questions

When does rigid beat EMT?
Where the raceway needs to survive impact and weather on its own: service masts, exposed low runs, loading areas, and installs the inspector calls out for physical damage protection. EMT covers lighter-duty runs at lower cost; both quote through the desk.

Do you stock other rigid trade sizes?
The quoted stick is 2 in. x 10 ft. Other trade sizes, elbows, nipples, and couplings are quoted on request through the desk.

Can it serve as the ground path?
Yes. Assembled with listed fittings and installed per NEC, rigid metal conduit serves as an equipment grounding conductor.

How do sticks join?
Threaded couplings and fittings, the standard method for the type. Field threads are cut, reamed, and sealed per standard practice.

Documents

Download the available product documents below. If a document is not linked yet, use the SKU during quote review.

Project pricing, lead time, freight routing, and final configuration are confirmed during quote review before order release.

Support and request quote workflows stay available throughout specification and order planning.