Light Archon Mainstay load centers anchor 200A services with a plug-on neutral bus and the space counts bigger houses actually need: 30-space and 40-space configurations indoor and outdoor, value packs with branch breaker assortments, surge-device versions, and a compact 8-space outdoor unit with feed-through lugs for downstream panels. Quote-first: the trade desk confirms the configuration and breaker schedule before release.

The fully distributed neutral bar means combination arc fault breakers plug on at any space, with no pigtail management per the published listing. Straight-in mains save cable, the cover self-adjusts for flush finishes on indoor units, and the interior rotates for overhead or underground feed. Ground and neutral bars accept up to three 10-14 equipment grounds per termination, and the distributed split branch neutral carries up to half again more terminals than the baseline standard requires per the published listing. The rep-verified interrupt rating is 22 kA, confirmed per configuration at quote review.

Highlights

  • 200A plug-on neutral platform, 8 to 40 spaces, 16 to 80 circuits
  • Factory-installed main breaker on every configuration
  • Fully distributed neutral: arc fault breakers land on any space
  • Value packs include a branch breaker assortment, itemized at quote review
  • Surge-device configurations add whole-panel surge protection
  • Speed-terminal configurations cut neutral landing time per the published listing
  • Feed-through 8-space outdoor unit feeds downstream panels
  • Overhead or underground feed by rotating the interior
  • 22 kA rep-verified interrupt rating; UL Listed

Specification Table

Current Rating 200A
Input Rating 120/240V, single phase, 3-wire
Configurations 8 to 40 spaces, 16 to 80 circuits
Bus Plug-on neutral, fully distributed
Interrupt Rating 22 kA rep-verified, per configuration at quote review
Enclosure Steel; NEMA 1 indoor or NEMA 3R outdoor by configuration
Mounting Flush or surface indoor; surface outdoor
Feed Overhead or underground, rotating interior
Breaker Compatibility Accepts Light Archon Aegis and Talos series 1 in. plug-on breakers and industry-standard 1 in. formats - verified at quote review
Included Main breaker factory installed; branch assortment on value packs; surge device on SPD versions
Grounding Up to three 10-14 equipment grounds per bar termination
Certifications UL Listed
Warranty Light Archon limited trade warranty, confirmed at quote review

Included Components

  • Enclosure with cover, NEMA rated per configuration
  • Factory-installed 200A main breaker
  • Branch breaker assortment on value pack configurations, itemized at quote review
  • Plug-on surge protection device on SPD configurations
  • Feed-through lugs on the 8-space outdoor configuration

Installation Notes

  • Installed by a licensed electrician as service equipment or subpanel per plan.
  • Keep NEC working clearance at the enclosure face; flush or surface mount per configuration.
  • Bond and ground per NEC; separate grounded and bonding conductors in subpanel use.
  • Rotate the interior for overhead or underground feed before conductor landing.
  • Branch breaker schedule and surge device placement are finalized at quote review.

Warranty and Support

  • Covered by the Light Archon limited trade warranty; term confirmed at quote review
  • Submittal sheets and dimensional PDFs available for every configuration
  • Support through the Light Archon trade desk

Frequently Asked Questions

What breakers does it accept?
Light Archon Aegis and Talos series 1 in. plug-on branch breakers and industry-standard 1 in. formats; the exact schedule for your job is verified at quote review.

What comes in a value pack?
The enclosure, cover, factory-installed 200A main breaker, and an assortment of single-pole and double-pole branch breakers. The assortment is itemized at quote review since it varies by configuration.

Which configurations mount outdoors?
The 30-space outdoor value packs and the 8-space feed-through unit carry NEMA 3R enclosures. Indoor units are NEMA 1 with flush or surface mounting.

What does the surge device configuration add?
A factory-fitted plug-on surge protection device covering the whole panel, on the 30-space outdoor and 40-space indoor versions.

Can it feed a detached building?
The 8-space outdoor unit carries feed-through lugs sized for downstream panels, which is the clean way to chain a garage or shop panel. Conductor sizing is confirmed at quote review.

Documents

Download the available product documents below. If a document is not linked yet, use the SKU during quote review.

Project pricing, lead time, freight routing, and final configuration are confirmed during quote review before order release.

Support and request quote workflows stay available throughout specification and order planning.