Light Archon SteelPath EMT is the thin-wall galvanized steel raceway for exposed and concealed runs in commercial and residential work. Sticks quote in five trade sizes, with 5 ft cuts in the two smallest sizes.

Unthreaded galvanized steel takes set-screw and compression fittings, bends cleanly with a standard bender in the smaller sizes, and serves as the equipment ground path when assembled with listed fittings per NEC. A smooth interior coating protects conductors on the pull. UL 797 class per the published listing.

Highlights

  • Galvanized steel thin-wall raceway, UL 797 class
  • Trade sizes 1/2 through 2 in.; 10 ft sticks with 5 ft cuts in 1/2 and 3/4 in.
  • Serves as the equipment ground path with listed fittings per NEC
  • Smooth interior coating eases conductor pulls
  • Bends with standard hand and power benders in the smaller sizes
  • Exposed or concealed, interior or exterior with raintight fittings
  • Quote-first supply with bundle counts for production jobs

Specification Table

Type EMT thin-wall raceway
Material Galvanized steel, unthreaded
Trade sizes 1/2, 3/4, 1-1/4, 1-1/2, 2 in.
Stick lengths 10 ft standard; 5 ft in 1/2 and 3/4 in.
Interior Smooth coated raceway for easy pulls
Fittings Set-screw and compression; raintight compression outdoors
Ground path Equipment ground with listed fittings per NEC
Listings UL 797 class; CSA listed
Use Exposed or concealed, interior or exterior
Reference weight 3/4 in. by 10 ft stick listed at 4.6 lb
Supply model Quote-first; bundle counts welcome

Included Components

  • Conduit sticks only; fittings and straps quoted separately

Installation Notes

  • Ream cut ends before conductors go in.
  • Use raintight compression fittings on exterior runs.
  • Strap and support per NEC spacing for the trade size.
  • Field bends need the correct bender shoe per size; factory sweeps quote on request.
  • Fitting types and counts are confirmed at quote review.

Warranty and Support

  • Backed by the Light Archon trade supply program; warranty terms are confirmed at quote review.
  • Submittal sheets and takeoff review support are available from our electrical supply desk.

Frequently Asked Questions

What fittings does it take?
Set-screw and compression EMT fittings in matching trade sizes. Use raintight compression fittings outdoors. Fitting counts are quoted with the conduit.

Can EMT serve as the ground path?
Yes. Assembled with listed fittings and installed per NEC, it serves as an equipment ground path.

Do you stock 1 in. EMT?
The quoted size run covers 1/2 through 2 in. as listed; 1 in. sticks are quoted on request through the desk.

Are 5 ft sticks available?
Yes, in 1/2 and 3/4 in. for tight van stock and small punch lists.

Documents

Download the available product documents below. If a document is not linked yet, use the SKU during quote review.

Project pricing, lead time, freight routing, and final configuration are confirmed during quote review before order release.

Support and request quote workflows stay available throughout specification and order planning.